User manual OPTICOM OPERA E1-T1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OPTICOM OPERA E1-T1. We hope that this OPTICOM OPERA E1-T1 user guide will be useful to you.

Lastmanuals help download the user guide OPTICOM OPERA E1-T1.


Mode d'emploi OPTICOM OPERA E1-T1
Download
Manual abstract: user guide OPTICOM OPERA E1-T1

Detailed instructions for use are in the User's Guide.

[. . . ] User Manual for the OPERATM E1/T1 Option OPR-002-E1T-P This information may be subject to change. All brand and product names are trademarks and/or registered trademarks of their respective owners. Copyright © 2001 by OPTICOM GmbH · www. opticom. de CONTENTS Contents Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i 1 2 3 Preface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Setup of the Cable Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Setup of the E1/T1 Board Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3. 1 Configuration Parameters Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3. 1. 1 Protocols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3. 1. 2 Call Progress Tones. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3. 1. 3 D-Channel Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 3. 1. 4 Line Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 3. 1. 5 T1 Framing Method. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 3. 1. 6 CAS ABCD Idle Pattern . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 3. 1. 7 Coding Law. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 3. 1. 8 Line Build Out. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 3. 1. 9 Destination Numbering Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 3. 1. 10 Destination Numbering Plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 3. 1. 11 Source Numbering Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 3. 1. 12 Source Number Presentation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 3. 1. 13 Source Number Screening . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 3. 1. 14 Source Phone Number. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 3. 1. 15 Source Phone Subnumber. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 3. 1. 16 Transfer Capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 3. 1. 17 Inter Exchange Prefix Number. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 3. 1. 18 B-Channel Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 3. 2 Using the OptiConfTM Application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 3. 2. 1 The Parameter Field "Protocol Type". . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 3. 2. 2 The Parameter Field "Protocol Version". . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 3. 2. 3 The Parameter Field "Protocol Subversion". . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 3. 2. 4 The Parameter Field "Call Progress Tones Conf. ". . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 3. 2. 5 The Parameter Field "DChannel Configuration". . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 3. 2. 6 The Parameter Field "Line Code" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 3. 2. 7 The Parameter Field "T1 Framing Method". . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 3. 2. 8 The Parameter Field "CAS ABCD Idle Pattern". . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 3. 2. 9 The Parameter Field "Coding Law" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 3. 2. 10 The Parameter Field "Line Build Out ". . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 3. 2. 11 The Parameter Field "Termination Side" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3. 2. 12 The Parameter Field "Set B-Channel Parameters". . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3. 3 Setting up B-Channel Configuration Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Signal Acquisition Using OptiCallTM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 OptiCallTM Command Line Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Measurement Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 6. 1 Example Parameter Settings for Several Protocol Types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 6. 1. 1 E1_Euro_ISDN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 6. 1. 2 T1_CAS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 6. 1. 3 E1_MFCR2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 6. 1. 4 E1_CAS_R2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 6. 1. 5 T1_NI2_ISDN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 6. 1. 6 T1_5ESS_10_ISDN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 6. 1. 7 T1_DMS100_ISDN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 6. 2 Example 1: Stand Alone Loop Measurement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 6. 3 Example 2: Measurements From a Batch File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 i 4 5 6 CONTENTS 7 Options for Advanced Users. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 7. 1 Editing a Call Progress Tones Configuration File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 7. 2 Editing a CAS Protocol Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 7. 2. 1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 7. 2. 2 Constructing or Modifying a CAS Protocol Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 7. 2. 3 Table Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 7. 2. 4 State's Line Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 7. 3 Protocol Trace Option. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 7. 3. 1 Tracing CAS/Robbed Bit Protocols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 7. 4 Downloadables Construction Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 7. 4. 1 Location. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 7. 4. 2 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 7. 4. 3 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Technical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Glossary of Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 ANI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 CLI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 8 9 10 10. 1 10. 2 ii CHAPTER 1: PREFACE 1 Preface The documentation on hand is meant as a completion to the user manual of the OPERATM measurement system. This documentation describes the E1/T1 Option (OPR-002-E1T-P) for the OPERATM voice quality analyzer. [. . . ] "E1_T1-Line4. wav" is the relevant file if you want to use PSQM or PESQ, "E1_T1-Line34. wav" is the relevant file if an analysis of Echo shall be performed with OPERATM. 31 CHAPTER 6: MEASUREMENT EXAMPLES 6. 3 This example describes only the command line functionality to acquire the signals with a system under test. For an example of how to use the command line option to analyze files, please refer to the OPERATM user manual. Again, you will have to take care that the telephone line is looped back on the far end, so you will get your signal to the terminating line. Connect both trunks of the E1/T1 interface board to the SUT. As described in the example in 6. 1, we have to configure the E1/T1 interface using the OptiConfTM dialog, before we run the automated measurement from the script file. In OptiConfTM TM, we select the protocol type "E1_MFCR2", the protocol version "Mfcr2_ITU" and the subversion using 5 digits without ANI function (see Figure 6. 1). Since all the other parameter values are fine for our example, we leave them as they are and start the initialization process by clicking on the Apply button. Note: Example 2: Measurements From a Batch File Only run the batch file after you have received the message that the initialization process has been finished. Only then the board configuration is available for the automated execution. We now want to use the same settings as described in Example 1. We will perform a loop measurement, the number to dial is "12345", the reference file is taken from the location "C:\programme\opera\DefaultRefFile. wav", destination directory is "D:\test#E1_T1". The originating line index is chosen corresponding to the index number of the device entry "4: E1_MFCR2_ITU_5Digits_no_ANI Port 0 BCh 0" and the terminating line index would then be 34. We will use the Mirror parameter to set the terminating line. The correct offset value is then 30 in accordance with the chosen E1 protocol. Thus, the correct command line will be as follows (should be written in one line in the batch file): Opticall /Exec ­Loop ­OriginatingLine 4 ­Mirror 30 ­Phonenumber 12345 ­RefFileOrigin C:\programme\opera\DefaultRefFile. wav ­ RefFileTermination C:\programme\opera\DefaultRefFile. wav ­ DestinationPath D:\test ­Root E1_T1 After the batch file has been executed, the resulting files will be D:\test\E1_T1-Line4. wav (to be used for PSQM or PESQ analysis) and D:\test\E1_T1-Line34. wav (for Echo analysis). 32 CHAPTER 7: OPTIONS FOR ADVANCED USERS 7 Options for Advanced Users 7. 1 The Call Progress Tones Configuration File contains the definitions of the call progress tones to be detected/generated by the board. Users can use either one of the files supplied by OPTICOMor construct their own file. The Call Progress Tones Configuration File used for the configuration of the E1/T1 interface board is a binary file (with extension . dat). Users can construct their own configuration file by starting with the Windows ini file format and then converting it into binary format using the "Downloadable construction utility" described in Section 7. 4. The Windows® ini file format contains two sections, [NUMBER OF CALL PROGRESS TONES] and [CALL PROGRESS TONE #X]. A description of both of them is given in the following. [NUMBER OF CALL PROGRESS TONES] Editing a Call Progress Tones Configuration File Only one key is provided: · Number of Call Progress Tones - Defines the number of call progress tones to be defined in the file. - Containing the Xth tone definition (starting from 1 and not exceeding the number of call progress tones defined in the first section) using the following keys: [CALL PROGRESS TONE #X] · Tone Type - Call progress tone type as defined in Table 7. 1 (assign the number and not the enumeration): Number Definition Tone Type CallProgressDialTone CallProgressRingingTone CallProgressBusyTone CallProgressCongestionTone CallProgressSpecialInfoTone CallProgressWarningTone CallProgressReorderTone 1 2 3 4 5 6 7 Table 7. 1: Available tone types and assigned number definitions. · Low Freq [Hz] - Frequency in Hertz of the lower tone component in the case of a dual frequency tone or the frequency of the tone in the case of a single tone. High Freq [Hz] - Frequency in Hertz of the higher tone component in the case of dual frequency tone or zero (0) in the case of a single tone. Low Freq Level [-dBm] - Generation level in dBm of the lower tone component in the case of a dual frequency tone or the generation level of the tone in the case of a single tone. · · 33 CHAPTER 7: OPTIONS FOR ADVANCED USERS · High Freq Level [-dBm] - Generation level in dBm of the higher tone component in the case of a dual frequency tone, or zero (0) in the case of a single tone. First Signal On Time [10 msec] - "Signal On" period (in 10 msec units) for the first cadence on-off cycle. First Signal Off Time [10 msec] - "Signal Off" period (in 10 msec units) for the first cadence on-off cycle. [. . . ] The B-Channel number the event is associated with. The connection ID the event is associated with. The ConId is related to the CallHandle. Table 7. 6: Description of the fields of a textual trace file for CAS/Robbed Bit protocols [AUDI01]. In the text file, there are two events which seem to be duplicated, but are from different sources, which means that the event came from one source and was sent to another. For example: EV_CAS_0_1 From_DSP and then the same event From_Table, means DSP sends this event and Table receives it later. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OPTICOM OPERA E1-T1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OPTICOM OPERA E1-T1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag