User manual OPTICON OPI 2201

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OPTICON OPI 2201. We hope that this OPTICON OPI 2201 user guide will be useful to you.

Lastmanuals help download the user guide OPTICON OPI 2201.


Mode d'emploi OPTICON OPI 2201
Download
Manual abstract: user guide OPTICON OPI 2201

Detailed instructions for use are in the User's Guide.

[. . . ] Imager Scanner OPI 2201 The OPI 2201 scanner enables smooth scanning of linear (1D) and 2D symbologies with an autofocus function. Specifications Manual Opticon OPI 2201 Specifications Manual All information subject to change without notice. Document History Model Number: Edition: Date: OPI 2201 Initial Release 2008-10-31 Specification Number: Original Spec Number: SS08044 Copyright 2009 Opticon. All rights reserved. This manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic or machine readable form without prior written consent of Opticon. Limited Warranty and Disclaimers PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR USING THE PRODUCT. Serial Number A serial number appears on all Opticon products. This official registration number is directly related to the device purchased. [. . . ] Output Specifications Parameter Output voltage Maximum current Power ripple 6. 0 V ±5% 2. 0 A 0. 1 Vp-p max. Optical Specifications The auto-focus function is enabled after aiming the center of the barcode by the laser light. The aiming operation is activated when pressing the trigger key. The scan engine requires 100ms to capture the image with auto-focus after triggering. Ambient light might affect the detection of the scan field and the time that is required for scanning. 7. 1. Imager Scanning Parameter Light-emitting element Emission wavelength Light output Light-emitting element (4 x LEDs) Specification Red laser diode 650 ±10 (25° C) 1. 0 or less InGaIP red LED Peak wave length Directivity angle: 2 1/2 (*1) Maximum radiation output (*2) Unit -- nm mW -- 645 nm 30° 60° 12600 lx 5040 mcd -- Note Scanning method Number of effective pixels Frame rate Scan angle SXGA (1. 3 million pixels) CMOS area sensor (gray scale) SXGA 1280 (column) x 1024 (row) Readable pixel count is 1282 dots (column) ×1026 dots (row) Up to 30 Horizontal: 40 Vertical: 32 MCLK: 48MHz Thermal protection fps ° *1: The radiation pattern features: 2pcs in 2 types of LED (which have different directivity angles). *2: The figure is measured at 25ºC, IF = 50mA. Class 1M compliant output. 14 Opticon OPI 2201 Specifications Manual 7. 2. Imager Output Item Image data format Specification Windows Bitmap, JPEG, TIFF Note Black spot may appear on the images, however, it does not affect the scanning specifications. Shades of gray Range of output image Resolution of output image Interface of output image Transmission time 256, 16, 2 Select in horizontal and vertical scale. Full, 1/2, 1/3, 1/4 RS-232C, USB-VCP USB-VCP (Full speed) RS-232C (115. 2 kbps) About 4 sec About 120 sec Shades of gray: 256 Resolution: Full 8. Technical Specifications The conditions for technical specifications are as follows, unless otherwise specified in each section. Conditions Ambient temperature and humidity: Ambient light: Angles Background: Room temperature (5 to 35º C) Room humidity (45% to 85% RH) 1000 to 1500 lx (on the barcode surfact) Pitch: = 0°, Skew: = 15°, Tilt: = 0° Barcode = black Space = white Margin = white Background of label = black 0. 9 or higher 6. 0 V Approve the performance when decoding is successful in all ten tests. (Decoding is deemed successful when scanning is successful in 70% of the tests. ) Code 39 (resolution 0. 1 and 0. 127 mm) and JAN codes used for the tests are OPTOELECTRONICS test samples printed by a normal printer. (NW ratio = 1: 1. 25) PCS (in scanning 2D symbologies) Power supply voltage: Decoding test: Barcode test sample (1D and 2D) 15 Opticon OPI 2201 Specifications Manual Test Samples: 1D Symbologies Code 39 Resolution 0. 1 mm 0. 127 0. 254 mm 1. 0 mm Code 39 0. 9 Symbology PCS Size (mm) 10 x 9 11 x 10 14 x 10 56 x 30 Digits 4 2 JAN Resolution 0. 260 mm 0. 260 mm Symbology 13-digit JAN 8-digit JAN PCS 0. 9/0. 45 0. 9 Size (mm) 25 x 19 17. 5 x 15. 5 Digits 13 8 Test Samples: 2D Symbologies PDF417 Resolution 0. 254 mm 0. 127 mm Level-4 0. 9 Error Correction PCS Size (mm) 26 x 16. 5 13 x 8 Characters 17 QR Code (Model 2) Resolution 0. 339 mm 0. 127 mm M 0. 9 Error Correction PCS Size (mm) 10 x 10 4x4 Characters 44 Data Matrix Resolution 0. 339 mm 0. 169 mm ECC200 0. 9 Model PCS Size (mm) 8x8 4x4 Characters 40 Micro QR Resolution 0. 212 mm Error Correction L PCS 0. 9 Size (mm) 5x5 Characters 11 16 Opticon OPI 2201 Specifications Manual 8. 1. Print Contrast Signal (PCS) 0. 45 or higher (over 70% of reflectivity of space and quiet zone). PCS= Reflectance of white barReflectance of black bar Reflectance of white bar Scanning performance may decline if dirt or scratches mar the optical window. Conditions MRD Distance Barcode test sample (1D & 2D) 32% and higher (With over 70% reflectivity of space and quiet zone. ) 120 mm from the focal plane of the scanner. PDF417 (Resolution: 0. 254 mm, PCS: 0. 45) 8. 2. Minimum Resolution Resolution 0. 1 mm 0. 127 mm 0. 169 mm 0. 212 mm Symbology Code 39 PDF417, QR Code Data Matrix Micro QR 17 Opticon OPI 2201 Specifications Manual 8. 3. Depth of Field The depth of field is measured from the edge of the scanner. The scanning range is within the circular arc centered on the scan origin. Figure 3: Depth of field 18 Opticon OPI 2201 Specifications Manual Symbology Code 39 Resolution (mm) 0. 1 0. 127 0. 254 1. 0 0. 127 0. 254 0. 127 0. 339 0. 169 0. 339 0. 212 Decode Depth (mm) 15-100 15-155 15-365 90-1450 15-160 30-375 15-40 15-280 15-120 35-275 15-100 PCS 0. 9 PDF417 QR Code Data Matrix Micro QR Code 0. 9 0. 9 0. 9 0. 9 19 Opticon OPI 2201 Specifications Manual 8. 4. Skew Angle and Dead Zone Skew angle: = ±65° 8. 4. 3. [. . . ] JIS C6802: 2005: Class 1M IEC 60825-1+A2: 2001 Class 1M 18. 2. EMC EN55022 EN55024 VCCI Class B: This is a Class B product, to be used in a domestic environment based on the Technical Requirement of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Please install and use the equipment according to the instruction manual. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OPTICON OPI 2201

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OPTICON OPI 2201 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag