User manual OREGON RMS 300

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OREGON RMS 300. We hope that this OREGON RMS 300 user guide will be useful to you.

Lastmanuals help download the user guide OREGON RMS 300.


Mode d'emploi OREGON RMS 300
Download
Manual abstract: user guide OREGON RMS 300

Detailed instructions for use are in the User's Guide.

[. . . ] Press RESET after each battery change. LOCATION MEANING Main unit batteries low Remote sensor batteries low : Decrease values in setting mode; deactivate clock signal reception 8. °C / °F: Select temperature unit 9. EU / UK: Select the nearest radio signal (RMS300 only) REMOTE SENSOR (FIG 3) Clock / alarm area Outdoor temperature area 2 REMOTE SENSOR The remote sensor can collect data from up to 3 channels. To set up the remote sensor: 4 1 3 5 1. [. . . ] If you have deactivated the clock signal reception, do not set a value for time zone. RMS300A: Select the time zone: (P) Pacific, (E) Eastern, (C) Central or (M) Mountain. To auto-scan channels: Press and hold + MEM to display each channel's recorded data in sequence for 3 seconds. To select channel, press . To toggle between current, minimum and maximum temperature/ humidity record of a selected channel: Press MEM. To clear the temperature / humidity record displayed: Press and hold MEM. ICE ALERT (CHANNEL 1 ONLY) If the temperature falls between 3°C to -2 °C (37°F to 28°F), the green ice alert LED indicator will flash continuously, and will stop flashing once the temperature is out of this range. NOTE The language options are English (E), German (D), French (F), Italian (I), and Spanish (S). To select clock display mode: Press MODE to toggle between clock with seconds, clock with weekday and calendar. CONNECTION TO PC Weather data of temperature and humidity readings can be uploaded to the computer by connecting the main unit to the computer. To upload the weather data to the computer: 1. It can be available for download at this address: http://10. 1. 6. 110/rms300. exe 2. Follow instructions in the software programme. Plug one end of the USB cable into the USB port and the other end into the computer. TEMPERATURE AND HUMIDITY To toggle temperature unit: Press °C / °F. 5 RMS300 IM EN R3. indd 5 1/4/08 11:52:36 AM EN EN 4. If data upload is completed, the display will show " · · · · · ". NOTE Computer system requirements: Operating system: Microsoft Windows 98 or above Processor: 300 MHz or higher CPU speed RAM: 128 megabytes (MB) Hard disk free space: 50 Mbytes (GB) CD-ROM or DVD drive NOTE The USB is only used for uploading weather data. It cannot be used for charging battery power. BACKLIGHT Press LIGHT to activate LED backlight for 5 seconds. Signal frequency 433 MHz Temperature range -5°C to 50°C (23°F to 122°F) Temperature 0. 1°C (0. 2°F) resolution Humidity range 25% - 95% Humidity resolution 1% Power 2 x UM-3 (AA) 1. 5 V batteries REMOTE UNIT (THGN132N) LxWxH 50 x 22 x 96 mm (1. 9 x 0. 9 x 3. 8 in) Weight 62 g (2. 2 ounces) without battery Signal frequency 433 MHz Number of channel 3 Transmission range 30 m (98 ft) unobstructed Temperature range -20°C to 60°C (-4°F to 140°F) Humidity range 25% - 95% Humidity resolution 1% Power 1 x UM-3 (AA) 1. 5 V battery RESET Press RESET to return to the default settings. PRECAUTIONS · · Do not subject the unit to excessive force, shock, dust, temperature or humidity. Do not cover the ventilation holes with any items such as newspapers, curtains etc. If you spill liquid over it, dry it immediately with a soft, lint-free cloth. Do not clean the unit with abrasive or corrosive materials. Do not tamper with the unit's internal components. Do not mix new and old SPECIFICATIONS TYPE MAIN UNIT LxWxH Weight DESCRIPTION 72 x 58 x 165 mm (2. 8 x 2. 3 x 6. 5 in) 190 g (6. 7 oz) without battery · · · 6 RMS300 IM EN R3. indd 6 · 1/4/08 11:52:36 AM batteries. · · Images shown in this manual may differ from the actual display. When disposing of this product, ensure it is collected separately for special treatment and not as normal household waste. [. . . ] Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: We Name: Address: Telephone No. : Oregon Scientific, Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OREGON RMS 300

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OREGON RMS 300 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag