User manual OREGON WMR80A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OREGON WMR80A. We hope that this OREGON WMR80A user guide will be useful to you.

Lastmanuals help download the user guide OREGON WMR80A.


Mode d'emploi OREGON WMR80A
Download
Manual abstract: user guide OREGON WMR80A

Detailed instructions for use are in the User's Guide.

[. . . ] Wireless Full Weather Station Kit Model: WMR80 / WMR80A USER MANUAL INTRODUCTION Thank you for selecting the Oregon ScientificTM Weather Station (WMR80 / WMR80A). The base station is compatible with other sensors. To purchase additional sensors, please contact your local retailer. are compatible with this CONTENTS Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The rain gauge should be mounted horizontally about 1 meter (3 feet) from the ground in an open area away from trees or other obstructions to allow rain to fall naturally for an accurate reading. To set up the Rain Gauge: NOTE For best results, ensure the base is horizontal to allow maximum drainage of any collected rain. SET UP BASE STATION NOTE Install batteries in the remote sensor before the base station matching the polarities (+ and -). Detach table stand by pulling away from base station. Remove screws and slide the cover off in an upwards motion. Insert the batteries (2 x UM-3 / AA), matching the polarities (+ / -). Press RESET after each battery change. 3. 6. Insert the batteries, matching the polarities (+ / -). Replace table stand by inserting back into base station. 3. Remove the fibre tape. To ensure a level plane: Put a few drops of water on the cross at the base of the funnel to check the horizontal level. It is recommended that you use alkaline batteries with this product for longer performance. 1 3 4 5 2 NOTE Batteries should not be exposed to excessive heat such as sunshine or fire. WMR80_IM_EN_R1. indd 5 2008. 7. 1 7:11:31 PM EN EN The battery icon indicator following areas: AREA Weather Forecast Area Temperature or Humidity Area Wind Speed / Wind Direction / Wind Chil Area UVI / Barometer / Rainfall Area may appear in the MEANING Battery in the base station is low. The displayed channel indicates the outdoor sensor for which battery is low. Battery in the UV / Rain sensor is low. NOTE For best reception, the base station should be placed on a flat, non-metallic surface near a window in an upper floor of your home. The antenna should be placed away from electrical appliances and not be moved around when searching for a signal. CLOCK / CALENDAR To manually set the clock: (You only need to set the clock and calendar if you have disabled the clock radio reception). Press SELECT to navigate to the Clock Area. Press and hold MODE to change the clock setting. Press + / - to increase / decrease the setting value. Repeat steps 3 to 4 to set the time zone offset hour (+ / -23 hours), 12 / 24 hour format, hour, minute, year, date / month format, month, date and weekday language. NOTE If you enter +1 in the time zone setting, this will give you your regional time plus 1 hour. If you are in the US (WMR80A only) set the clock to: 0 for Pacific time +2 for Central time +1 for Mountain time +3 for Eastern time. CLOCK RECEPTION This product is designed to synchronize its calendar clock automatically once it is brought within range of a radio signal: WMR80: · EU: DCF-77 signal: within 1500 km (932 miles) of Frankfurt, Germany. · UK: MSF-60 signal: within 1500 km (932 miles) of Anthorn, England. WMR80A: · WWVB-60 signal: within 3200km (2000 miles) of Fort Collins Colorado. Press SELECT to navigate to the Humidity Area. [. . . ] The contents of this manual may not be reproduced without the permission of the manufacturer. Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. Please note that some units are equipped with a battery safety strip. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OREGON WMR80A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OREGON WMR80A will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag