User manual OZ-VISION V4000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OZ-VISION V4000. We hope that this OZ-VISION V4000 user guide will be useful to you.

Lastmanuals help download the user guide OZ-VISION V4000.


Mode d'emploi OZ-VISION V4000
Download
Manual abstract: user guide OZ-VISION V4000

Detailed instructions for use are in the User's Guide.

[. . . ] V4000 Remote Video System Control Center Guide Installer Version V4000 Control Center User Guide 1 CONTENTS Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Getting Started. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installing Control Center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Defining Screen Resolution and Colors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] A red/white/blue frame will appear. Resize and move this frame by using the mouse Right click inside the frame to set the View Port. The frame will turn red and white only and the unit will send updates only in the marked area. To disable View Port, right click in the frame then click the left click outside the frame and right click again anywhere. V4000 Control Center User Guide 18 Setting Remote Unit Parameters A few seconds after pressing the tuning button in the control center, the remote setup window will appear. You can temporarily set the image resolution. (High-resolution delivers sharper images, with greater detail but slows the transmission rate). The resolution changes made here are temporary and the default parameters will be loaded on the next communication To set, update or change the remote unit's parameters, click on the Unit Power-on Parameters button. To upgrade the remote system's firmware directly from your PC via the phone, click Upload Firmware, which opens the upload window. To save the camera's brightness setting as the default. · Type the source file name or click browse. · After the transfer, you will be disconnected from Enter the new password, confirm it and click Ok Temporarily sets the system mode to Black & White or Color video. Press Ok to confirm. The Set Remote Password button allows you to set or change the remote password. V4000 Control Center User Guide 19 Remote units parameters are divided into six tabs: General Parameters Every remote unit has a unique ID number. This identification number will appear in the ID and unit version fields. These parameters cannot be changed. · Alarm Phone Num #1 / #2 ­ Use these fields to enter the phone numbers that the unit will call in case of an alarm or a callback request. If you have only one phone line, type the same phone number in both fields. · Cameras ­ Checks the active cameras at the remote site. · Quality ­ Sets the compression ratio to the image quality you require. Remember, high-quality images are transmitted slower. · Resolution ­ Sets the resolution to the quality you require. Remember high-resolution provides sharper images and greater detail but slows down the frame rate. · Black & White or Color- Selects black and white or color options. · PAL/NTSC- Sets the camera's format to NTSC or PAL. *** This change will be effective only after rebooting the unit. · Upload ­ Click this button to update the unit with the new parameters. · Save to file ­ Click this button to save the new parameters to a local file in your PC. You can later restore the values by reloading the saved file. [. . . ] The operators are in the left right top and bottom of the picture. Zoom and focus are in the corners. 9. Note: If the Dome works with the RS485 protocol, connect the Dome to the unit to the TxDA and to the TXDB pins 1(-) and 2(+). If the Dome is working with the RS232 protocol, connect the Dome to pins 2 (RX) and 3 (TX) in the RS232 plug of the unit. There is an option to install an RS232 to RS485 converter. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OZ-VISION V4000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OZ-VISION V4000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag