User manual PANASONIC CSVZ12SKE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

Sponsored Links

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PANASONIC CSVZ12SKE. We hope that this PANASONIC CSVZ12SKE user guide will be useful to you.

Lastmanuals help download the user guide PANASONIC CSVZ12SKE.


PANASONIC CSVZ12SKE : Download the complete user guide (8318 Ko)

Manual abstract: user guide PANASONIC CSVZ12SKE

Detailed instructions for use are in the User's Guide.

[. . . ] It also provides moisturizing effect on the skin or hair and reduces the smell in the room and constrains propagations of mold and bacteria. Operation conditions Use this air conditioner under the following temperature range. Indoor DBT 32 16 30 16 10 16 WBT 23 11 DBT 43 -10 24 -30 -30 Outdoor WBT 26 18 - 2 Quick guide 1 3 Table of contents Inserting the batteries 1 Open the back cover of remote control 2 Insert AA batteries (can be used ~ 1 year) 3 Close the cover Safety precautions . 15 OFF CANCEL 1 CLOCK RESET MENU Accessories • AA batteries × 2 Basic operation 1 Select the desired mode • Press AUTO, COOL, DRY or HEAT button to start the operation. [. . . ] Since the working pressure is higher than that of refrigerant R22 models, some of the piping and installation and service tools are special. Especially, when replacing a refrigerant R22 model with a new refrigerant R32 model, always replace the conventional piping and flare nuts with the R32 and R410A piping and flare nuts on the outdoor unit side. For R32 and R410A, the same flare nut on the outdoor unit side and pipe can be used. Models that use refrigerant R32 and R410A have a different charging port thread diameter to prevent erroneous charging with refrigerant R22 and for safety. Also, when storing the piping, securely seal the opening by pinching, taping, etc. This appliance shall be stored in a room without continuously operating open flames and ignition sources. This appliance shall be stored so as to prevent mechanical damage from occurring. 6 After a long period of use, make sure the installation rack does not deteriorate to prevent the unit from falling down. To prevent malfunction or damage of the remote control: • Remove the batteries if the unit is not going to be used for a long period of time. € New batteries of the same type must be inserted following the polarity stated. Power supply Do not disconnect the plug by pulling the cord to prevent electric shock. OFF 2 Set the time English +8/10°C HEAT To use maintenance heating Example: OFF at 8:00 How to use (Green) (Orange) (Green) (Blue) (Green) Indicator AUTO COMFORT To create comfort by monitoring the human presence & activity AIR SWING • It will be cancelled once the selected. Or FAN SPEED is POWER TIMER +8/10°C nanoe/ODOR CLEANUP Human activity sensor ECONAVI To optimise energy saving Sunlight sensor and remote control receiver Remote control display (the Backlight will be lit whenever pressing any button) AIR SWING AIR SWING To adjust airflow direction (Remote control display) AUTO AUTO • Keeps the room air circulated. • In COOL/DRY mode , if AUTO is set , the louvers swings left/ right and up/down automatically. € In HEAT mode, if AUTO is set, the horizontal louver is fixed at the predetermined position. COOL DRY HEAT FAN SPEED To select fan speed AUTO COMFORT ECONAVI AIR SWING AIR SWING FAN SPEED (Remote control display) AUTO nanoe POWERFUL QUIET • For AUTO, the indoor fan speed is automatically adjusted according to the operation mode. € This operation provides you with a comfortable environment while sleeping by gradually decrease and/or increase the set temperature within 1°C for avoiding the room from unnecessary cooling and/or heating. € When used together with the daily timer, sleep operation has a priority. 11 How to use * Stops operation combined with AUTO COMFORT function after human sensor not detecting for 3 hours or more. English • This operation release odor from the internal indoor unit. The operation activates for 20 minutes, and resume to the presetting operation automatically. € OFF timer: ODOR CLEANUP continuous display and the operation stopped after odor removal end. [. . . ] Remove air filter 1 Raise Close it securely Attach air filter Rail (Orange) Ditch Arm 1 Insert at both sides 2 Close down For seasonal inspection after extended non-use • Checking of remote control batteries. After 15 minutes of operation, it is normal to have the following temperature difference between air inlet and air outlet vents: COOL: ≥ 8°C Air Purification Filter HEAT: ≥ 14°C Air Purification Filter • Do not wash/rinse the filter with water. : CZ-SA33P For extended non-use • Activate HEAT mode for 2~3 hours to remove moisture left in the internal parts thoroughly to prevent mould growth. / Cleaning instructions Pressing ECONAVI button for 5 seconds, and display shows “OPEN LOUVER”, the louvers will be open. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC CSVZ12SKE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC CSVZ12SKE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag