User manual PANASONIC PAWDHWM80ZNT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PANASONIC PAWDHWM80ZNT. We hope that this PANASONIC PAWDHWM80ZNT user guide will be useful to you.

Lastmanuals help download the user guide PANASONIC PAWDHWM80ZNT.


Mode d'emploi PANASONIC PAWDHWM80ZNT
Download
Manual abstract: user guide PANASONIC PAWDHWM80ZNT

Detailed instructions for use are in the User's Guide.

[. . . ] The appliance may be used by children older than 8 years old, elderly persons and persons with physical, sensory or mental disabilities or lacking experience and knowledge, if they are under supervision or taught about safe use of the appliance and if they are aware of the potential dangers. Children should not play with the appliance. Children should not clean or maintain the appliance without supervision. Always transport the heat pump in an upright position; exceptionally, it may be tilted by 35° in all directions. [. . . ] Power failure protection In case of power failure, the settings remain stored for up to 23 hours. After restarting, the heat pump operates in the same mode it was operating in before the power failure. Operation at lower temperatures When the appliance is switched on, the fan starts first and operates for one minute (symbol no. If the temperature of inlet air is lower than -7 °C, the fan is turned off. The heat pump operates in the reserve mode (symbol no. The possibility of switching to normal mode is checked every 2 hours by switching on the fan for one minute. If the temperature of inlet air is higher than -7 °C, the heat pump switches to normal mode of operation (symbols 16 and 20 are displayed). The heat pump is on, the screen remains unlit and inactive. At lower air temperatures, the evaporator defrosting cycle is started if necessary. The fields 2, 4, 6, 11, 13 and 15 remain inactive. Defrosting takes place until the conditions for normal operation of the heat pump are achieved. After successful defrosting, the heat pump returns to normal operation (symbols 16 and 20 are displayed). If defrosting is unsuccessful after two consecutive attempts, the controlling unit displays an error message. 4 starts flashing, accompanied by warning beeps. 12 and the pump switches automatically to heating with electric heaters. The error code can be deleted at any time by pressing field no. Setting the clock and day of the week  7 shows a flashing number of the day of the week.  By pressing + or – you can set the number of the day of the week (1 – Monday, …, 7 – Sunday). 12 again (flashing hour setting is displayed).  By pressing + or – set the hour (by holding + or – you can speed up the setting). By pressing + or – you can change the temperature setting from 10 °C to 75 °C (preset to economic temperature of 55 °C).  The setting is stored by pressing field no. [. . . ] 11: LCD-berøringsskjerm Forklaring: 1 - Signalregulering for betjening av 13 - Start av hurtigoppvarming "TURBO" solfangere** 14 - Indikator for driften av 2 - Alternativ varmekilde er slått på varmeelementet (varmere) 15 - Oppstart av oppvarming til maks. 3 - Signalregulering for betjening av temperaturnivå oljevarmer** 16 - Signalregulering av kompressordrift 4 - Indikasjon, oversikt over driftsfeil, 17 - Signalregulering av driften av antitilgang til servicemeny legionellaprogram 5 - Visning og oppsett av temperatur i °C 18 - Mengdevisning for varmt vann 6 - Start og oppsett av FERIE-program 19 - Signalregulering av tining 7 - Ukedag 20 - Signalregulering av viftedrift (1 . (Hvis du slår av varmepumpen for en lengre periode må pumpen tømmes for vann slik at det ikke er fare for at vannet fryser). Dersom du har behov for mer varmtvann enn varmepumpen kan varme opp i løpet av en periode, trykk på felt nr. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC PAWDHWM80ZNT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC PAWDHWM80ZNT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag