User manual PANASONIC S28MK2E5

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PANASONIC S28MK2E5. We hope that this PANASONIC S28MK2E5 user guide will be useful to you.

Lastmanuals help download the user guide PANASONIC S28MK2E5.


Mode d'emploi PANASONIC S28MK2E5
Download
Manual abstract: user guide PANASONIC S28MK2E5

Detailed instructions for use are in the User's Guide.

[. . . ] Indoor Units Wall Mounted (K2 type) S-22MK2E5 S-28MK2E5 S-36MK2E5 Operating Instructions Air Conditioner Outdoor Units mini (LE1 type) U-4LE1E5 U-5LE1E5 U-6LE1E5 U-4LE1E8 U-5LE1E8 U-6LE1E8 2WAY (ME1 type) U-8ME1E81 U-10ME1E81 U-12ME1E81 U-14ME1E81 U-16ME1E81 U-18ME1E81 U-20ME1E81 3WAY (MF1 type) U-8MF1E8 U-10MF1E8 U-12MF1E8 U-14MF1E8 U-16MF1E8 (MF2 type) U-8MF2E8 U-10MF2E8 U-12MF2E8 U-14MF2E8 U-16MF2E8 Indoor Units 4-Way Cassette 60x60 (Y2 type) S-22MY2E5 S-28MY2E5 S-36MY2E5 S-45MY2E5 S-56MY2E5 ENGLISH 2 ~ 15 Before operating the unit, read these operating instructions thoroughly and keep them for future reference. 172 PRODUCT INFORMATION If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate on the bottom of the cabinet. _______________________ Date of purchase ______________________________________________________________ Dealer’s address ______________________________________________________________ Phone number________________________________________________________________ SAFETY PRECAUTIONS The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance: This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death. [. . . ] The airflow direction may be different from the display on the remote controller. Zone ‘‘A’’ for cooling Zone ‘‘B’’ for heating Indoor unit Horizontal directions (manual) The horizontal airflow direction can be adjusted manually by moving the vertical vanes to the left or right. Fm Page 11 Tuesday, February 12, 2013 2:53 PM ADJUSTING AIRFLOW DIRECTION FOR MULTIPLE INDOOR UNITS USING SINGLE REMOTE CONTROLLER (WIRED) • Auto Flap ( ) button • If multiple indoor units are connected to a remote controller, the airflow direction can be set for each indoor unit by selecting the indoor units (see the operation below). To set the airflow for individual units, press the UNIT button. Display shows the indoor unit number under group control. Set the airflow direction for the indoor unit that is shown on the display. Each time UNIT is pressed, the indicator changes in the order shown below. When nothing is displayed, you can make the setting for all indoor units in one operation. The unit number is displayed as Outdoor Unit Number–Indoor Unit Number. It varies depending on the number of units under group control. 2–4 • • • One outdoor unit and eight indoor units No display Unit No. Fm Page 12 Tuesday, February 12, 2013 2:53 PM SPECIAL REMARKS ‘‘DRY’’ Operation How it works • • • • Once the room temperature reaches the level that was set, the unit repeats the cycle of turning on and off automatically. In order to prevent the humidity in the room from rising again, the indoor fan also turns off when the unit stops operating. The fan speed is set to ‘‘LO. ’’ automatically , and cannot be adjusted. €‘DRY’’ operation is not possible if the outdoor temperature is 15 °C or less. Heating Operation Heating performance • Because this appliance heats a room by utilizing the heat of the outside air (heat pump system), the heating efficiency will fall off when the outdoor temperature is very low. If sufficient heat cannot be obtained with this heat pump, use another heating appliance in conjunction with this unit. When the outdoor temperature is low, frost or ice may form on the outdoor heat exchanger coil, reducing the heating performance. when this happens , a microcomputer-controlled defrosting system operates. At the same time, the fan on the indoor unit stops (or runs at very low speed in some cases) and the ‘‘STANDBY’’ indicator appears on the display until defrosting is completed. Heating operation then restarts after several minutes. [. . . ] Type Y2, type K2 : • • • Ne jamais déplacer manuellement le volet contrôlé par la télécommande (volet de circulation d’air vertical). Elke unit moet correct geaard zijn met een aardedraad of via de bedrading van de stroomtoevoer. Zorg voor een apart stopcontact voor elke unit en in elke afzonderlijke lijn voor een stroomschakelaar, stroomonderbreker en aardlekschakelaar ter bescherming tegen overstroom. Zorg voor een apart stopcontact voor elke unit en conform de bedradingsregels moet er volledige ontkoppeling, dat wil zeggen een ontkoppeling van het stopcontact in alle polen worden geïmplementeerd in de vaste bedrading. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC S28MK2E5

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC S28MK2E5 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag