[. . . ] INDOOR UNIT Low Silhouette Ducted (F1 type) Ceiling (T2 type) 4-Way Cassette (U1 type) 4-Way Cassette (U1 type) S-36PU1E5 S-45PU1E5 S-50PU1E5 S-60PU1E5 S-71PU1E5 S-100PU1E5 S-125PU1E5 S-140PU1E5 S-71PT2E5 S-100PT2E5 S-125PT2E5 S-140PT2E5 S-71PF1E5 S-100PF1E5 S-125PF1E5 S-140PF1E5 ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference. Indb 1 2013/06/07 9:37:30 Thank you for purchasing this Panasonic product. Safety Precautions The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance: Contents Safety Precautions . 95 WARNING CAUTION Prohibited matters This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death. [. . . ] Wiring must be done by a qualified electrician. Operation Preparation Turn the power mains on 5 hours before the start of operation. (For warm-up) Leave the power mains ON for continuous use. ON NOTE Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time. For business users in the European Union If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information. [Information on Disposal in other Countries outside the European Union] These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal. Note for the battery symbol (bottom two symbol examples): This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved. Indb 4 2013/06/07 9:37:47 Names of Parts INDOOR UNIT Water drain Air intake Air intake Ceiling panel (optional) Air outlet (4 locations) Air intake grille (air intake) Air outlet Air outlet Air outlet OUTDOOR UNIT Air intake U1 type (4-Way Cassette) Air outlet PE1 (50 type) PE1 (60, 71 type) PE1 (100, 125, 140 type) PEY1 (60, 71 type) PEY1 (100, 125 type) PEY1 (140 type) Optional Wireless Remote Controller For all indoor units E NGLISH Water drain Air intake grille (air intake) T2 type (Ceiling) Air outlet duct * Bolt anchor * Suspension bolt * Indoor unit Ceiling material * Air-outlet grille * * Field supplied Timer Remote Controller For all indoor units F1 type (Low Silhouette Ducted) Read the operating instructions included with the Remote Controller. Operation Mechanism Heating performance Since this air conditioner utilizes outside air for heating, its heating performance deteriorates as outside temperature decreases. (Due to heat pump system) →In that case, use another heating appliance. This appliance may start defrosting operation to melt frost formed in the outdoor unit. 1Defrosting starts: The indoor unit fan stops (or the speed becomes extremely slow). →” ” (STANDBY) appears. €‘DRY’’ operation Defrosting Once the room temperature reaches the level that was set, the outdoor unit repeats the cycle of turning on and off automatically. When the outdoor unit is turned off, the indoor unit fan will stop, too. (To prevent the humidity in the room from rising again) When the room temperature is more likely to reach the level that was set, the fan speed is set to ‘‘breeze’’ (light wind) automatically. €‘DRY’’ operation is not possible if the outdoor temperature is 15 °C or less. 2Heating operation resumes after several minutes: The indoor unit fan remains stopped (or it will run at a very slow speed) until the indoor heat exchanger coil warms up sufficiently. → ” ” (STANDBY) is shown. 3Defrosting is complete: The indoor unit fan starts operation. [. . . ] € When air discharge temperature is low during heating operation, or during defrost operation, horizontal wind flow is made automatically. • The flap position may be set individually. (U1 type) • The flap moves to the standard position once, and then turns to the set airflow direction. € Dust accumulated inside the indoor unit is discharged. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC S60PT2E5

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC S60PT2E5 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag