User manual PARADOX 748PLUS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PARADOX 748PLUS. We hope that this PARADOX 748PLUS user guide will be useful to you.

Lastmanuals help download the user guide PARADOX 748PLUS.


Mode d'emploi PARADOX 748PLUS
Download
Manual abstract: user guide PARADOX 748PLUS

Detailed instructions for use are in the User's Guide.

[. . . ] The sum of the values of the lit keys in the second row correspond to the first hexa digit as shown in the example below. = Second digit = 8 + 2 = 10 = First digit = 4 + 2 + 1 = 7 Therefore 2-digit data = 7A Note: Values 10 to 15 represent hexa digits A to F respectively. See keypad to the left. Esprit+ - 1 - Programming Guide STREAMLINED SECTION PROGRAMMING This is an alternate method to Hexa Programming. The addresses (000 - 043 and 300 - 527) programmed in the Hexa Programming method are grouped into 67 sections where each section contains four addresses (i. e. Using this method allows you to program 8 digits (4 addresses) without having to exit and reenter addresses. [. . . ] (seconds) Programmable delay before alarm transmission (005 to 063 seconds) (000 = disabled) (seconds) Recent closing delay (000 = disabled) Future Use Figure 2: Decimal Display For LED Keypads Default Address 044 045 046 047 048 049 050 051 052 053 054 055 056 057 058 60 seconds 45 seconds 45 seconds 5 minutes 600 mSec. 30 minutes Disabled 5 seconds 48 seconds 059 060 061 ___ / ___ / ___ ___ / ___ / ___ ___ / ___ / ___ Esprit+ - 9 - Programming Guide FEATURE SELECT PROGRAMMING Addresses 062 to 126 are programmed using the Feature Select Programming method. In this method, every key on the keypad in each address represents an option or feature. Pressing a key will display it on the keypad and pressing it again will extinguish the key. The ON or OFF status of each key determines the selected feature. Addresses 080 to 085 are reserved for future use. To program using the Feature Select Programming method: 1) 2) 3) 4) Press [ENTER] + [INSTALLER CODE] (default: see Table 1 on page 1) The [ENTER] key will flash to indicate you are in programming mode Enter 3-digit [ADDRESS] (062 - 126) After entering the address, the keypad will display the feature selection status. Turn the keys ON or OFF by pressing the appropriate key until the desired options are set. Press the [ENTER] key to accept, there will be a confirmation "beep" indicating the options have been accepted. The [ENTER] key will flash to indicate that the software is awaiting the next address entry. Return to step 3 to continue programming or press [CLEAR] to exit programming mode 5) Table 3: Code Priority For System "A" / STAY KEY SELECT: [1] User #: 062: User #: 17 064: User #: 33 066: 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 1 [2] 2 [3] 3 [4] 4 [5] 5 [6] 6 [7] 7 [8] 8 [9] 9 [10] [11] [12] [BYP] [MEM] [TRBL] [2ND] 10 11 12 13 14 15 16 Table 4: Code Priority For System "B" / AWAY KEY SELECT: [1] User #: 068: User #: 17 070: User #: 33 072: 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 1 [2] 2 [3] 3 [4] 4 [5] 5 [6] 6 [7] 7 [8] 8 [9] 9 [10] [11] [12] [BYP] [MEM] [TRBL] [2ND] 10 11 12 13 14 15 16 Table 5: Code Priority for Codes with Bypass Access KEY SELECT: [1] User #: 074: User #: 17 076: User #: 33 078: 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 1 [2] 2 [3] 3 [4] 4 [5] 5 [6] 6 [7] 7 [8] 8 [9] 9 [10] [11] [12] [BYP] [MEM] [TRBL] [2ND] 10 11 12 13 14 15 16 Esprit+ - 10 - Programming Guide KEY Telephone Line Monitoring (TLM) 086: See "TLM" table at right Keyswitch = regular arm Keyswitch arming Call back Auto arm on time Auto arm on no movement Pulse dialing Partitioning Silent zone/panic generates a silent alarm (1:2) Pulse Europe See "Reporting Options" table at right N/A Bell squawk on arm/disarm Auto zone shutdown OFF / [2ND] [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [BYP] [MEM] [TRBL] KEY ON Stay arm / System A Enabled Enabled Enabled Enabled Tone dialing (DTMF) Enabled generates only a report (1:1. 5) Pulse USA KEY [2ND] [1] OFF OFF OFF ON ON OFF ON ON - TLM disabled - TLM generates trouble only - generates an alarm if armed - silent alarm becomes audible (address 086, key [9] has to be OFF) Reporting Options KEY [11] [12] OFF OFF OFF ON ON OFF ON ON - Reporting disabled - Regular reporting - Split* reporting (Alarms & System) - Double reporting N/A Enabled Enabled Report Dialing Sequence (tel. no. ) Regular: 1, 2, 1, 2, 1, 2, 1, 2, fail to comm. Split*: Alarms - 1, 1, 1, 1, 1, 1, 1, 1, fail to comm System - 2, 2, 2, 2, 2, 2, 2, 2, fail to comm Double: 1, 1, 1, 1, 1, 1, 1, 1, fail to comm 2, 2, 2, 2, 2, 2, 2, 2, fail to comm * On alarm, all reports are made to Tel. Once disarmed, system reports are made to Tel. #2. 088: Automatic event buffer transmission Panic 1 (keys [1] and [3]) Panic 2 (keys [4] and [6]) Panic 3 (keys [7] and [9]) Panic 1 silent Panic 2 silent Panic 3 silent Key [10] - regular arming Key [11] - stay or system A arm 6 digit access codes Tamper Recognition Beep on exit delay Report zone restore on bell cut-off Zones with EOL (1k ) Always report disarm OFF / [2ND] [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [BYP] [MEM] [TRBL] KEY ON Enabled Enabled Enabled Enabled Audible Audible Fire Enabled Enabled 4 digit access code Tamper / Wire Fault Definitions KEY System Armed Alarm as per individual zone definitions Always generate trouble and alarm, audible or silent as per individual zone definitions [10] OFF [11] OFF System Disarmed* - Tamper supervision disabled - No alarm, trouble code reported - Silent alarm. Trouble & alarm codes reported - Audible alarm. Trouble & alarm codes reported** OFF ON ON OFF ON ON Enabled On zone closure No EOL Only after alarm * Exception: for 24 hour zones, the tamper definition will follow the audible/silent alarm definition of the 24 hour zone. ** Silent zones will generate a silent alarm. 090: Exclude power failure from trouble display Zone (4, 9 or 15) enabled*** Auto arm = regular arm N/A N/A N/A No tamper bypass N/A Zone doubling (ATZ)**** Audible trouble warning Duress Keypad zone 1 supervision Keypad zone 2 supervision N/A N/A N/A OFF / [2ND] [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [BYP] [MEM] [TRBL] ON Enabled Disabled*** Stay / System A N/A N/A N/A Tamper follows zone bypass definition N/A Enabled**** Enabled Enabled Enabled Enabled N/A N/A N/A **** NOTE 2: This feature applies to the 728+, 728DZ8+, 738+ and 748+ only. *** NOTE 1: This feature applies to the 728+, 728DZ8+, 738+ and 748+ only. When ATZ is enabled (address 090 key [8] ON) and zone 3 is defined as a fire zone, this zone must be disabled. If using a 728+ or 728DZ8+, zone 4 will be disabled. If using a 738+, zone 9 will be disabled. [. . . ] For the hardwired connections, refer to Single Zone Connections on page 13 and Advanced Technology Zone Connections on page 14. Keypads - LED Keypads 636, and 646 - LCD Keypad 642 The maximium number of keypads per installation is dependent on the auxiliary output, which is not to exceed 400mA. Refer to the Reference & Installation Manual for the current consumption table. Refer to Figure 11, Figure 12 and Figure 13 on pages 14 and 15 for information keypad zone connections*. * NOTE: The 728EX4+ and 728DZ8+ control panels do not support keypad zones. Esprit+ - 16 - Programming Guide ESPRIT 738+ / 738EX+ WIRING DIAGRAM If using a 738+, please refer to Inset 1 for the input terminals. For the hardwired connections, refer to Single Zone Connections on page 13 and Advanced Technology Zone Connections on page 14. Keypads - LED Keypads 636, and 646 - LCD Keypad 642 The maximium number of keypads per installation is dependent on the auxiliary output, which is not to exceed 400mA. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PARADOX 748PLUS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PARADOX 748PLUS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag