[. . . ] StayD Installer Setup Guide *For new unprogrammed panels or reset panels* StayD Enabled Panels Control Panel MG5000 / MG5050 SP5500 / SP6000 / SP7000 Step A: Define the zones Set up your zones as you would normally and define which zones are disabled during Stay or Sleep arming. See the Zone Definitions table in the panel's respective Programming Guide. Step B: Assign entry point zones and paths to keypads 1 Go to each keypad that requires entry point zone assignment. When you assign a path to a keypad, StayD is automatically enabled. [. . . ] Default = 000 (no delay) Entry/Exit Paths · StayD consists of programmed pathways, where the user enters and exits the property through pre-defined routes, with only the route's respective zones open for passage. A path can be programmed for each individual keypad, with a maximum of four zones per path. Path zones must be defined as follow or delay zones only. · The first zone programmed in a path is its designated entry point (e. g. Designated entry points are not common to multiple paths. There is only one designated entry point per path. Also, they are only used when entering/exiting with a remote control (see below). · The system only disables the path zones corresponding to the keypad at the point of entry/exit, while re-arming as you enter/exit. · Validate your entry path by entering your code. You only need to enter your code once to validate one or more paths. For example, you have entered your home through Path 1 and are at your keypad. Before disarming the system, you notice a Path 2 zone has opened. If you know it is a member of your family and would like to validate the open zone, enter your user code. All paths, including Path 1, will subsequently be validated. · You must enter your code for every zone that opens that is not part of any path. For example, if you have entered through Path 1 and a non-path zone opens, you must enter your code once to validate your path and once for the non-path zone. If you do not validate the non-path zone, the system will fall in alarm. Entry/Exit with a Keypad · When entering with a keypad, the path zones will fall into entry delay, allowing you to reach the keypad. Use the keypad to disarm the system and switch to Stay arm mode. · When exiting with a keypad, only the path zones will fall into delay (same as exit delay), allowing you to leave while the rest of the premises remains secure. Entry/Exit with a Remote Control · When using a remote control, the path you use is defined by a designated entry point. For example: if after pressing the remote control to disarm the system you trigger zone 1, the system will check to see which path(s) include zone 1. [. . . ] When you close the open zone (window, door, etc. ) that zone will re-arm. · When closing an exterior zone such as a window or door, a delay will start allowing you to close the zone properly. The delay starts when you close the zone, and you must keep the zone closed for the entire delay period for it to re-arm. This is especially useful for windows that stick thus reducing false alarms. paradox. com Printed in Canada - 12/2007 STAYD-EI03 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PARADOX STAYD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PARADOX STAYD will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag