User manual PEAVEY 800 MIXER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PEAVEY 800 MIXER. We hope that this PEAVEY 800 MIXER user guide will be useful to you.

Lastmanuals help download the user guide PEAVEY 800 MIXER.


Mode d'emploi PEAVEY 800 MIXER
Download
Manual abstract: user guide PEAVEY 800 MIXER

Detailed instructions for use are in the User's Guide.

[. . . ] Two channels of +4 balanced to -10 single-ended. RCA and 1/4" jacks on -10 dBV side. Electronically balanced +4 dBu In the Out (XLR). Unity gain option on single-ended to balanced side. The IATM 10/4 provides convenient interface capability for the professional recording environment. [. . . ] Two channels perform independent -10 to +4 level interfacing from single-ended 1/4" or RCA jacks to transformerless balanced XLR termination. The gain of these two channels is switchable between +12 dB and 0 dB (Unity). The remaining two channels perform independent +4 (balanced) to -10 (unbalanced) level interfacing. RCA and 1/4" jacks are provided on the -10 dBV end. 5&6 7&8 -10 dBV to +4 dBu Interface RCA Inputs (1 & 2) Provided for connection of -10 dBV nominal level sources utilizing RCA pin-type termination. These jacks are paralled with the A & B 1/4" inputs. (3 & 4) 1/4" Phone Inputs (3 & 4) Provided for connection of -10 dBV nominal level sources utilizing 1/4" phone termination. These jacks are paralleled with the A & B RCA inputs. (1 and 2) XLR Outputs (5 & 6) Balanced termination for connecting +4 dBu nominal level equipment. Outputs Unbalanced: Balanced: Frequency response: Distortion: SNR Unbalanced out: Balanced out: Power requirements: 93 dB - Ref: -10 dBV 101 dB - Ref: +4 dB (+12 dB gain) 110 dB - Ref: +4 dBu (unity gain) External wall mount power supply (16. 5 VAC) Available in 120 V, 220 V and 240 V version 3&4 13 9 & 10 SPECIFICATIONS: Inputs Unbalanced: Balanced: -10 dBV nominal (. 316 Volts), +14 dBV maximum (5 Volts) +4 dBu nominal (1. 22 Volts) +26 dBu maximum (16 Volts) -10 dBV nominal (. 316 Volts) +14 dBV maximum (5 Volts) +4 dBu nominal (1. 22 Volts) +26 dBu maximum (16 Volts) +0, -1 dB 20 Hz to 20 kHz Less than . 005% THD +4 dBu to -10 dBV Interface XLR Inputs (7 & 8) Balanced input termination for +4 dBu nominal level sources. 1/4" Phone Outputs (9 & 10) Unbalanced output termination for connecting -10 dBV nominal level equipment utilizing 1/4" jacks. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point they exit from the apparatus. Note for UK only: If the colors of the wires in the mains lead of this unit do not correspond with the terminals in your plug, proceed as follows: a) The wire that is colored green and yellow must be connected to the terminal that is marked by the letter E, the earth symbol, colored green or colored green and yellow. b) The wire that is colored blue must be connected to the terminal that is marked with the letter N or the color black. c) The wire that is colored brown must be connected to the terminal that is marked with the letter L or the color red. Only use attachments/accessories provided by the manufacturer. Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. Unplug this apparatus during lightning storms or when unused for long periods of time. Refer all servicing to qualified service personnel. [. . . ] Unplug this apparatus during lightning storms or when unused for long periods of time. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. Write for our free booklet "Shock Hazard and Grounding. " Connect only to a power supply of the type marked on the unit adjacent to the power supply cord. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PEAVEY 800 MIXER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PEAVEY 800 MIXER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag