User manual PEAVEY AUTOMIX 2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PEAVEY AUTOMIX 2. We hope that this PEAVEY AUTOMIX 2 user guide will be useful to you.

Lastmanuals help download the user guide PEAVEY AUTOMIX 2.


Mode d'emploi PEAVEY AUTOMIX 2
Download
Manual abstract: user guide PEAVEY AUTOMIX 2

Detailed instructions for use are in the User's Guide.

[. . . ] Instead, when the level is adjusted above Ò0Ó, the other channels are attenuated to make the channel being adjusted sound louder in the mix without adding to the system gain. The low cut filter provides a low frequency rolloff that will help minimize unwanted noise (handling of mics, bumping of table, etc. OFF/+48 When this switch is in the +48 position, +48 volts of phantom power is supplied to the mic ± terminals. This provides power for condenser mics and should be defeated when using dynamic microphones or unbalanced inputs. [. . . ] If desired, a control voltage can be inserted to command 0 to 70dB of attenuation. MUTEBUS The mutebus is a control port that when shorted to ground will mute all channels that are assigned to the mutebus approximately 45dB. The channels to be muted must be assigned to the mutebus using the internal switch marked OFF/MBUS. see INTERNAL PANEL FEATURES , page 4 and diagram page 7. LINK PORT To increase the number of inputs available, multiple Automixers can be linked together. linking automixers is a very simple process. It can be done with a small flat-head screwdriver and a short length of four conductor shielded wire. The following diagram and procedures will ensure proper linking. Select the mixer to be used as the master and place its link switch in the ÒmasterÓ position. All other mixers in the system should have their link switches in the ÒslaveÓ position. you now have a 16 (or more) channel automatic mixer. The master controls of the unit chosen as ÒmasterÓ should be used to control the system. LINK SWITCH The link switch is used to place the unit in the master or slave mode of operation. A standalone unit should always be in the master mode. IEC INLET (AC) With the Power Switch in the off (O) position, plug the power cord into this connector prior to plugging into your AC power source. Always ensure proper AC voltage and grounding practices are utilized (proper voltage is labeled under inlet). NOTE: FOR UK ONLY As the colors of the wires in the mains lead of this apparatus may not correspond with the colored markings identifying the terminals in your plug, proceed as follows: (1) The wire which is colored green and yellow must be connected to the terminal which is marked by the letter E or by the earth symbol or colored green or green and yellow. (2) The wire which is colored blue must be connected to the terminal which is marked with the letter N or the color black. (3) The wire which is colored brown must be connected to the terminal which is marked with the letter L or color red. 21dBu) with channel and master controls set for maximum gain. All controls down One channel nominal, Master level nominal All controls down One channel send nominal, Monitor master nominal (Hum and noise measurements: 22 Hz to 22 kHz BW) GENERAL SPECS: Remote volume range: Off channel attenuation: Mute: 0dB to 70dB of attenuation 0dB to 70dB Channel is attenuated 45dB when Mute to ground connection is made. Multiple channels can be attenuation 45dB when MuteBus to ground connection is made. [. . . ] PEAVEY SHALL NOT BE LIABLE FOR DAMAGES BASED ON INCONVENIENCE, LOSS OF USE, LOST PROFITS, LOST SAVINGS, DAMAGE TO ANY OTHER EQUIPMENT OR OTHER ITEMS AT THE SITE OF USE, OR ANY OTHER DAMAGES WHETHER INCIDENTAL, CONSEQUENTIAL OR OTHERWISE, EVEN IF PEAVEY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. If this product is to be mounted in an equipment rack, rear support should be provided. Exposure to extremely high noise levels may cause a permanent hearing loss. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PEAVEY AUTOMIX 2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PEAVEY AUTOMIX 2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag