User manual PEAVEY FOUNDATION 5

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PEAVEY FOUNDATION 5. We hope that this PEAVEY FOUNDATION 5 user guide will be useful to you.

Lastmanuals help download the user guide PEAVEY FOUNDATION 5.


Mode d'emploi PEAVEY FOUNDATION 5
Download
Manual abstract: user guide PEAVEY FOUNDATION 5

Detailed instructions for use are in the User's Guide.

[. . . ] The collet mount supplied with the FOUNDATION 5 provides additional mechanical isolation from structure-born noise and mechanically coupled feedback. The supplied clamp effectively locks the microphone in place to deter theft or improper removal. In addition to the collet mount, the FOUNDATION 5 may be plugged directly into an XLR-type receptacle or mounted to a microphone stand or boom with a conventional microphone stand adapter. [. . . ] The FOUNDATION 5 can operate on any phantom power source that supplies DC voltage between 9~52V. An LED located in the base of the microphone (upper portion of the output module) indicates when the FOUNDATION 5 is powered. Dynamic range: 106 dB Power supply: 9~52 VDC Current consumption: 3 mA Dimensions: Top diameter 0. 5" (12. 5 mm) x length 18. 1" (460 mm) Net weight: 7. 75 oz. (220 g) Type: Back-electret condenser microphone Pickup pattern: Cardioid Frequency response: 50 Hz to 20 kHz Sensitivity: -39 dBV/Pa Rated impedance: 250 Ohms Features: · Back-electret condenser element · Cardioid pickup pattern · Specially tailored smooth frequency response · High gain before feedback · Collet-type mounting flange with mechanical isolation system · Security locking system to prevent unauthorized removal · Operational from 9~52 VDC phantom power source · LED power indicator Minimum load impedance: 1k Ohms Maximum SPL: 132 dB SPECIFICATIONS ARCHITECTURAL & ENGINEERING SPECIFICATIONS The microphone shall be backelectret, condenser type with a frequency response of 50 Hz to 20 kHz. The microphone shall have a cardioid response pattern with a rear response that is typically -20 dB from the front response. The microphone shall have an output level of -39 dBV/pascal with a nominal impedance of 250 Ohms. The microphone shall have a low-gloss finish. Microphone dimensions shall be 0. 5" (12. 5 mm) in diameter at the element and 18. 1" (460 mm) long. CAUTION: To preserve maximum vibration isolation, neither the output module nor the security clamp should come in contact with the collet or the mounting surface of the lectern. SECURITY LOCK PROVISION After the installation of the microphone, simply slip the security clamp around the microphone cable and position around the end of the output module beneath the mounting surface. Engage the jaws of the clamp and tighten securely by squeezing with your fingers or pliers. While the clamp is in place, the microphone cannot be removed. This prevents theft and protects the mechanical isolation system from damage likely to occur if the XLR on the microphone cable is pulled through the collet. To remove the microphone, disconnect the microphone cable from the output module and remove the security clamp by sliding one jaw downward until the teeth disengage. 2 YEAR LIMITED WARRANTY NOTE: For details, refer to the warranty statement. For copies of this statement, contact Peavey Electronics Corporation, at P. O Box 2898, Meridian, Mississippi 39301-2898, or go online to www. peavey. com. COLLET MOUNT INSTALLATION Remove template from carton. Position the template at the desired position on the lectern. [. . . ] For copies of this statement, contact Peavey Electronics Corporation, at P. O Box 2898, Meridian, Mississippi 39301-2898, or go online to www. peavey. com. COLLET MOUNT INSTALLATION Remove template from carton. Position the template at the desired position on the lectern. Placing it near the upper right or left corner of the reading surface is most practical. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PEAVEY FOUNDATION 5

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PEAVEY FOUNDATION 5 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag