User manual PEAVEY HYDRA

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PEAVEY HYDRA. We hope that this PEAVEY HYDRA user guide will be useful to you.

Lastmanuals help download the user guide PEAVEY HYDRA.


Mode d'emploi PEAVEY HYDRA
Download
Manual abstract: user guide PEAVEY HYDRA

Detailed instructions for use are in the User's Guide.

[. . . ] Sample rates of 32, 44. 1, or 48 kHz can be chosen. The MMDSP-AES also has a software-selectable sample-rate. It supports 32, 44. 1, and 48 kHz sampled AES/EBU standard digital audio and includes functionality to choose between internal or external sync sources. The HYDRA-CN operates only at a 48 kHz sampling rate. · ISA bus edge connectors enable easy mixing and matching of DPU boards for custom system configurations · Software-selectable sample-rates for the HYDRA, HYDRA-RJ and MMDSP-AES DPU boards. [. . . ] The HYDRA-CN operates only at a 48 kHz sampling rate. · ISA bus edge connectors enable easy mixing and matching of DPU boards for custom system configurations · Software-selectable sample-rates for the HYDRA, HYDRA-RJ and MMDSP-AES DPU boards. · Greater than 100 MIPS (Million Instructions Per Second) calculating speed · Double-precision DSP filtering for accurate filter characteristics · Exclusive V-Stac coding doubles processing efficiency Applications: · · · · · · · · · · · · · · · · · · · Stadiums Cruise ships Multi-purpose facilities Auditoriums Large-scale paging systems Schools Courts of law Airports University campus buildings Theme parks Performing arts centers Distance learning centers Hotel meeting room complexes Houses of worship Conference centers Teleconferencing systems Civic centers Theaters Arenas Features · 4 Motorola 56002 DSPs on each DPU board · 24-bit processing · 32 digital audio input channels and 32 digital audio output channels SPECIFICATIONS Digital Audio Channel Capacity: Up to 32 input channels and 32 output channels per DPU board ARCHITECT'S AND ENGINEER'S SPECIFICATIONS HYDRA: The MediaMatrix HYDRA DPU board shall provide digital audio signal processing for the MediaMatrix Mainframes and Miniframes. It shall interface to the MM-8802 Break-out-Box and/or the legacy MM-8800 Series Breakout-Box, both of which provide audio-todigital and digital-to-audio conversion of sound system signals. It shall employ (4) Motorola 56002 DSPs for 24-bit processing of 32 digital audio input channels and 32 digital audio output channels. The DPU board shall perform 128 MIPS (Million Instructions Per Second). The HYDRA DPU board shall operate at one of (3) software-selectable sampling rates: 32 kHz, 44. 1 kHz, or 48 kHz. It shall employ double-precision filter calculations for more accurate audio filter frequency centers and slope-rates. V-Stac coding shall be employed in the programming code to double the code's efficiency. During CPU failure, the MMDSP DPU board shall continue to operate without interruption. DSP processing of lesser capabilities shall not be acceptable. V-Stac coding shall be employed in the programming to double the code's efficiency. During CPU failure, the MMDSP-AES DPU board shall continue to operate without interruption. DSP processing of lesser capabilities shall not be acceptable. The DPU board shall be the MediaMatrix HYDRA-AES. HYDRA-CN: The MediaMatrix HYDRA-CN DPU board shall provide CobraNet® digital audio signal processing for the MediaMatrix Mainframes. It shall interface to the CAB Series CobraNet Break-out-Boxes which port real-time audio on to and off of a standard 100BaseT Ethernet network. It shall employ (4) Motorola 56002 DSPs for 24-bit processing of 32 digital audio input channels and 32 digital audio output channels. The DPU board shall perform 168 MIPS (Million Instructions Per Second). The HYDRA-CN DPU board shall operate at a 48 kHz audio-sampling rate. It shall employ double-precision filter calculations for more accurate audio filter frequency centers and slope-rates. [. . . ] The DPU board shall perform 168 MIPS (Million Instructions Per Second). The HYDRA-CN DPU board shall operate at a 48 kHz audio-sampling rate. It shall employ double-precision filter calculations for more accurate audio filter frequency centers and slope-rates. V-Stac coding shall be employed in the programming code to double the code's efficiency. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PEAVEY HYDRA

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PEAVEY HYDRA will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag