User manual PEAVEY IA 800 V

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PEAVEY IA 800 V. We hope that this PEAVEY IA 800 V user guide will be useful to you.

Lastmanuals help download the user guide PEAVEY IA 800 V.


Mode d'emploi PEAVEY IA 800 V
Download
Manual abstract: user guide PEAVEY IA 800 V

Detailed instructions for use are in the User's Guide.

[. . . ] Intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. CAUTION: To reduce the risk of electric shock, do not remove cover. WARNING: To prevent electrical shock or fire hazard, do not expose this appliance to rain or moisture. Before using this appliance, read the operating guide for further warnings. [. . . ] Due to our efforts for constant improvements, features and specifications listed herein are subject to change without notice. 1% @ 100W from 20 Hz to 20 kHz with both channels driven THD (one channel driven): IA 200V-70: < 0. 5 volts or 5 volts for rated output Input Impedance: 20 k ohms, balanced Hum and Noise: IA 200V-70: > -110 dB, "A" weighted referenced to rated power IA 200V-100: > -115 dB, "A" weighted referenced to rated power Crosstalk: > -70 dB, "A" weighted referenced to rated power Current Draw @ 1/8 power: IA 200V-70: 165 watts IA 200V-100: 217 watts Current Draw @ 1/3 power: IA 200V-70: 290 watts IA 200V-100: 315 watts Idle Current Draw: IA 200V-70: 38 watts in Standby Mode IA 200V-100: 45 watts in Standby Mode Maximum Current Draw: IA 200V-70: 485 watts IA 200V-100: 475 watts Thermal Emissions (BTU/hr. ): IA 200V-70: 760 watts @ 1/3 power IA 200V-100: 850 watts @ 1/3 power Cooling: 80mm DC fan, off until heatsinks reach 45oC, then variable speed Controls: 2 rear panel attenuators, sequential turn on/off Indicator LEDs: 2 Clip, 2 Signal, 2 LFC, 1 Protect, 1 Power Protection: Temp. , DC, turn-on bursts, subsonic, incorrect load or short Connectors: 8-pin plugable signal input, 4-pin plugable sequential power, 4-terminal barrier strip, IEC AC power connector Construction: 18 ga. Rack ears, extruded aluminum front panel Dimensions: 3. Due to our efforts for constant improvements, features and specifications listed herein are subject to change without notice. 1% @ 300W from 20 Hz - 20 kHz with both channels driven THD (2 x 8 ohms): < 0. 05% @ 200W from 20 Hz - 20 kHz with both channels driven THD (1 x 4 ohms): < 0. 73 volts @ 4 ohms, 2 volts @ 8 ohms Input Impedance: 20 k ohms, balanced Hum and Noise: > -108 dB, "A" weighted referenced to rated power @ 8 ohms Crosstalk: > -75 dB, "A" weighted referenced to rated power @ 8 ohms Current Draw @ 1/8 power: 670 watts @ 4 ohms, 460 watts @ 8 ohms Current Draw @ 1/3 power: 1, 055 watts @ 4 ohms, 650 watts @ 8 ohms Idle Current Draw: 30 watts in Standby Mode Maximum Current Draw: 1, 622 watts @ 4 ohms, 1, 010 watts @ 8 ohms Thermal Emissions (BTU/hr. ): 2, 915 @ 1/3 power 4 ohms, 1, 591 @ 1/3 power 8 ohms Cooling: 80mm DC fan, off until heatsinks reach 45° C, then variable speed Controls: 2 rear panel attenuators, sequential turn on/off Indicator LEDs: 2 Clip, 2 Signal, 2 LFC, 1 Protect, 1 Power Protection: Temp. , DC, turn-on bursts, subsonic, incorrect load or short Connectors: 8-pin plugable signal input, 4-pin plugable sequential power, 4-terminal barrier strip, IEC AC power connector Construction: 18 ga. Rack ears, extruded aluminum front panel Dimensions: 3. Due to our efforts for constant improvements, features and specifications listed herein are subject to change without notice. 1% @ 200W from 20 Hz - 20 kHz with both channels driven IA 400V-100: < 0. 15% @ 200W from 20 Hz - 20 kHz with both channels driven THD (one channel driven): IA 400V-70: < 0. 5 volts or 5 volts for rated output Input Impedance: 20 k ohms, balanced Hum and Noise: > -110 dB, "A" weighted referenced to rated power Crosstalk: IA 400V-70: > -70 dB, "A" weighted referenced to rated power IA 400V-100: > -65 dB, "A" weighted referenced to rated power Current Draw @ 1/8 power: IA 400V-70: 415 watts IA 400V-100: 385 watts Current Draw @ 1/3 power: IA 400V-70: 600 watts IA 400V-100: 565 watts Idle Current Draw: IA 400V-70: 38 watts in Standby Mode IA 400V-100: 43 watts in Standby Mode Maximum Current Draw: IA 400V-70: 970 watts for rated power IA 400V-100: 840 watts for rated power Thermal Emissions (BTU/hr. ): IA 400V-70: 1591 watts @ 1/3 power IA 400V-100: 1472 @ 1/3 power Cooling: 80mm DC fan, off until heatsinks reach 45oC, then variable speed Controls: 2 rear panel attenuators, sequential turn on/off Indicator LEDs: 2 Clip, 2 Signal, 2 LFC, 1 Protect, 1 Power Protection: Temp. , DC, turn-on bursts, subsonic, incorrect load or short Connectors: 8-pin plugable signal input, 4-pin plugable sequential power, 4-terminal barrier strip, IEC AC power connector Construction: 18 ga. Rack ears, extruded aluminum front panel Dimensions: 3. Due to our efforts for constant improvements, features and specifications listed herein are subject to change without notice. 1% @ 600W from 20 Hz - 20 kHz with both channels driven THD (2 x 8 ohms): < 0. [. . . ] PEAVEY ONE-YEAR LIMITED WARRANTY/REMEDY PEAVEY ELECTRONICS CORPORATION ("PEAVEY") warrants this product, EXCEPT for covers, footswitches, patchcords, tubes and meters, to be free from defects in material and workmanship for a period of one (1) year from date of purchase, PROVIDED, however, that this limited warranty is extended only to the original retail purchaser and is subject to the conditions, exclusions, and limitations hereinafter set forth: PEAVEY 90-DAY LIMITED WARRANTY ON TUBES AND METERS If this product contains tubes or meters, Peavey warrants the tubes or meters contained in the product to be free from defects in material and workmanship for a period of ninety (90) days from date of purchase; PROVIDED, however, that this limited warranty is extended only to the original retail purchaser and is also subject to the conditions, exclusions, and limitations hereinafter set forth. cONDITIONS , EXCLUSIONS , AND LIMITATIONS OF LIMITED WARRANTIES These limited warranties shall be void and of no effect , if: a. The first purchase of the product is for the purpose of resale; or b. The original retail purchase is not made from an AUTHORIZED PEAVEY DEALER; or c. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PEAVEY IA 800 V

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PEAVEY IA 800 V will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag