User manual PEAVEY LTD HB

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PEAVEY LTD HB. We hope that this PEAVEY LTD HB user guide will be useful to you.

Lastmanuals help download the user guide PEAVEY LTD HB.


Mode d'emploi PEAVEY LTD HB
Download
Manual abstract: user guide PEAVEY LTD HB

Detailed instructions for use are in the User's Guide.

[. . . ] 857 mm x 492 mm x 552 mm Rear: 33. 75 in. 857 mm x 219 mm x 552 mm Net Weight: 96 lbs. (43. 6 kg) Figure 3b - LTD HB H 2 Features · 47 Hz to 18. 5 kHz bandpass · 4" diaphragm, 1. 6" exit, ferrofluid equipped high frequency compression driver · Patented Quadratic Throat Waveguide · Carefully tailored directivity patterns · Flexible suspension provisions · Robust power handling capabilities · Passive crossover included · Biamplified crossover provisions Q & Directivity Index 100 20 Q 10 10 Di Applications · · · · · · · · · · · · · · · Stadiums Arenas Multi-purpose facilities Cruise ships Theme parks Houses of worship Live music venues Hotels meeting rooms Conference facilities Theaters Auditoriums Civic centers Judicial facilities Gymnasiums Performing arts centers 1 20 50 100 200 Figure 4 500 1k Frequency (Hz) 2k 5k 10k 0 20k Harmonic Distortion : 10% Rated Power 120 110 dB SPL (re 20 Pa) 100 90 80 70 60 50 20 50 100 200 500 1k Frequency (Hz) 2k 5k 10k 20k Description The new Peavey LTD HBV (vertical) and LTD HBH (horizontal) Loudspeaker Systems are two-way, vented low frequency enclosures using a 15 inch low frequency driver paired with a 60° (horizontal) by 40° (vertical) high frequency waveguide. [. . . ] The HF section employs a 1. 6 exit/100 mm voice coil compression driver mounted on one of Peavey's revolutionary new Quadratic Throat Waveguides. In the LTD HBH unit, the waveguide is rotated to provide a corresponding beamwidth which may be employed in low ceiling type applications. Both versions of the LTD HB have a full range sensitivity of 95 dB SPL ­ (1 watt/1 meter) and a maximum output of 130 dB at 1 meter (full range). The Peavey LTD HB is a high performance loudspeaker system for use in demanding sound reinforcement applications. The robust construction of the LTD HB provides power handling capacities of 750 w continuous, 1. 5 kW program and 3 kW peak (full range). The unit may be operated using the internal 1, 600 Hz passive crossover or Figure 5 2nd Harmonic 3rd Harmonic Harmonic Distortion : 1% Rated Power 110 100 dB SPL (re 20 Pa) 90 80 70 60 50 40 20 50 100 200 500 1k Frequency (Hz) 2k 5k 10k 20k Figure 6 3 2nd Harmonic 3rd Harmonic may be biamplified. Twelve 3/8 inch x 16 threaded mounting suspension points (three each top and bottom and two each sides and back) allow a variety of suspension configurations. Multiple units may be mounted to form a vertical/horizontal array [see limitations under mounting instructions]. Box Meridian, Mississippi 39301-2898. Frequency Response This measurement is useful in determining how accurately a given unit reproduces an input signal. The frequency response of the LTD HB is measured at a distance of 1-meter using a 1 watt (into the nominal impedance) swept-sine input signal. As shown in Figure 1, the selected drivers in the LTD HB combine to give a smooth frequency response from 47 Hz - 18. 5 kHz. Harmonic Distortion Second and third harmonic distortions vs. frequency are plotted in Figures 5 and 6 for two power levels. Ten percent (10%) of rated input power and either one percent (1%) of rated input power or one watt, whichever is greater. Distortion is read from the graph as the difference between the fundamental signal (frequency response) and the desired harmonic. As an example, a distortion curve that is down 40 dB from the fundamental is equivalent to 1% distortion. Directivity Beamwidth is derived from the -6 dB points from the polar plots (see Figure 3) which are measured in a whole space anechoic environment. Q and Directivity Index are plotted for the onaxis measurement position. [. . . ] As an example, a distortion curve that is down 40 dB from the fundamental is equivalent to 1% distortion. Directivity Beamwidth is derived from the -6 dB points from the polar plots (see Figure 3) which are measured in a whole space anechoic environment. Q and Directivity Index are plotted for the onaxis measurement position. These are specifications that provide a reference to the coverage characteristics of the unit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PEAVEY LTD HB

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PEAVEY LTD HB will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag