User manual PEAVEY SANCTUARY SSE 10 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PEAVEY SANCTUARY SSE 10. We hope that this PEAVEY SANCTUARY SSE 10 user guide will be useful to you.

Lastmanuals help download the user guide PEAVEY SANCTUARY SSE 10.


Mode d'emploi PEAVEY SANCTUARY SSE 10
Download
Manual abstract: user guide PEAVEY SANCTUARY SSE 10DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] SPECIFICATIONS SSETM 10 Description The SSE is a new enclosure series featuring high power ratings with custom components, a sleek look and a unique, snap-in metal grille. The SSE 10 is a twoway system featuring the highly acclaimed Peavey 14XT titanium compression driver with the diverse Sound Guard IV tweeter protection network and a maximumperformance 10" woofer for a smooth response. [. . . ] DO NOT suspend this unit upside down using the VersaMount system. signal assures the user that every portion of this system can withstand today's high technology music. This rating is contingent upon having a minimum of 3 dB of amplifier headroom available. Harmonic distortion Second and third harmonic distortions vs. frequency are plotted in figures 5 and 6 for two power levels. Ten percent (10%) of rated input power and either one percent (1%) of rated input power or 1 Watt, whichever is greater. Distortion is read from the graph as the difference between the fundamental signal (frequency response) and the desired harmonic. As an example, a distortion curve that is down 40 dB from the fundamental is equivalent to 1% distortion. Directivity factor, Q (Mean): 7. 19 ± 6. 07 Directivity index, Di (Mean): 8. 09 dB ± 2. 01 dB Transducer complement: Low frequency section: Premium-grade 10" woofer High frequency section: Peavey 14XTTM titanium diaphragm compression driver on a 90° x 60° constant directivity horn Dimensions (H x W x D): Front: 19. 63" x 15. 09" x 12. 12" 498 mm x 383 mm x 308 mm Rear: 19. 63" x 11. 09" x 12. 12" 498 mm x 383 mm x 308 mm Mounting Caution: Before attempting to suspend or mount this speaker, consult a certified structural engineer. The speaker may fall due to improper installation, resulting in serious injury and property damage. DO NOT suspend or mount any other product or device from this enclosure. All associated rigging is the responsibility of others. Box tuning frequency: Low frequency section: 78 Hz Net Weight: 29 lbs. (13. 2 kg) Frequency response This measurement is useful in determining how accurately a given unit reproduces an input signal. The frequency response of the SSE 10 is measured at a distance of 1meter using a 1 Watt (into the nominal impedance) swept-sine input signal. As shown in figure 1, the selected drivers in the SSE 10 combine to give a smooth frequency response from 80 Hz to 17 kHz. Harmonic distortion: 1% rated power Second harmonic: 100 Hz: 0. 43% 1 kHz: 0. 07% Third harmonic: 100 Hz: 0. 58% 1 kHz: 1. 02% 10% rated power Second harmonic: 100 Hz: 2. 28% 1 kHz: 0. 40% Third harmonic: 100 Hz: 0. 97% 1 kHz: 2. 02% Architectural and Engineering Specifications The loudspeaker system shall have an operating bandwidth of 80 Hz to 17 kHz. [. . . ] Peavey rates this loudspeaker system's power handling using a full-range form of the AES Standard 2-1984. Using audio band 20 Hz to 20 kHz pink noise with peaks of four times the RMS level, this strenuous test Enclosure materials and finish: Trapezoidal, dado-joined, 12 mm 9-ply Birch finished with a textured acrylic polyurethane, with a full-length metal grille covered with acoustical-grade grille 2 SPECIFICATIONS SSETM 10 Amplitude Response (1W 1m On-Axis) 110 dB SPL (re 20 Pa) 100 90 80 70 60 20 50 100 200 Figure 1 500 1k Frequency (Hz) 2k 5k 10k 20k Impedance 100 50 30 20 Z ( ) 10 5 3 2 1 20 50 100 200 500 1k Frequency (Hz) 2k 5k 10k 20k Figure 2 Beamwidth 360 300 Beamwidth (Degrees) 180 140 100 80 60 40 30 20 Horizontal Vertical 50 100 200 500 1k Frequency (Hz) 2k 5k 10k 20k Figure 3 Q & Directivity Index 100 20 Q 10 10 Di 1 20 50 100 200 Figure 4 500 1k Frequency (Hz) 2k 5k 10k 0 20k 3 Harmonic Distortion : 10% Rated Power 120 110 dB SPL (re 20 Pa) 100 90 80 70 60 50 20 50 100 200 500 1k Frequency (Hz) 2k 5k 10k 20k Figure 5 2nd Harmonic 3rd Harmonic Harmonic Distortion : 1% Rated Power 110 100 dB SPL (re 20 Pa) 90 80 70 60 50 40 20 50 100 200 500 1k Frequency (Hz) 2k 5k 10k 20k Figure 6 2nd Harmonic 3rd Harmonic 4 SPECIFICATIONS SSETM 10 Vertical Polar Patterns 6 dB per Division 90 o 90 60 o o 90 60 o o 60 o 30 o 30 o 30 o 0 o 0 o 0 o -30 o o -30 o o -30 o o -60 -90 o -60 -90 o -60 -90 o 50 Hz 90 o 63 Hz 90 60 o o 80 Hz 90 60 o o 60 o 30 o 30 o 30 o 0 o 0 o 0 o -30 o o -30 o o -30 o o -60 -90 o -60 -90 o -60 -90 o 100 Hz 90 o 125 Hz 90 60 o o 160 Hz 90 60 o o 60 o o 30 o 30 30 o 0 o 0 o 0 o -30 o o -30 o o -30 o o -60 -90 o -60 -90 o -60 -90 o 200 Hz 90 o 250 Hz 90 60 o o 315 Hz 90 60 o o 60 o o 30 o 30 30 o 0 o 0 o 0 o -30 o o -30 o o -30 o o -60 -90 o -60 -90 o -60 -90 o 400 Hz 500 Hz 630 Hz 5 Vertical Polar Patterns 6 dB per Division 90 o 90 60 o o 90 60 o o 60 o 30 o 30 o 30 o 0 o 0 o 0 o -30 o o -30 o o -30 o o -60 -90 o -60 -90 o -60 -90 o 800 Hz 90 o 1 kHz 90 60 o o 1. 25 kHz 90 60 o o 60 o 30 o 30 o 30 o 0 o 0 o 0 o -30 o o -30 o o -30 o o -60 -90 o -60 -90 o -60 -90 o 1. 6 kHz 90 o 2 kHz 90 o o 2. 5 kHz 90 60 o o 60 60 o o 30 o 30 30 o 0 o 0 o 0 o -30 o o -30 o o -30 o o -60 -90 o -60 -90 o -60 -90 o 3. 15 kHz 90 o 4 kHz 90 o o 5 kHz 90 60 o o 60 60 o o 30 o 30 30 o 0 o 0 o 0 o -30 o o -30 o o -30 o o -60 -90 o -60 -90 o -60 -90 o 6 6. 3 kHz 8 kHz 10 kHz SPECIFICATIONS SSETM 10 Vertical Polar Patterns 6 dB per Division 90 o 90 60 o o 60 o 30 o 30 o 0 o 0 o -30 o o -30 o o -60 -90 o -60 -90 o 12. 5 kHz 16 kHz 7 Horizontal Polar Patterns 6 dB per Division 0 30 o o o 0 -30 o o 0 -30 o o 30 o o 30 o o -30 o 60 -60 o 60 -60 o 60 -60 o 90 o -90 o 90 o -90 o 90 o -90 o 50 Hz 0 30 o o o 63 Hz 0 -30 o o 80 Hz 0 -30 o o 30 o o 30 o o -30 o 60 -60 o 60 -60 o 60 -60 o 90 o -90 o 90 o -90 o 90 o -90 o 100 Hz 0 30 o o o 125 Hz 0 -30 o o 160 Hz 0 -30 o o 30 o o 30 o o o -30 o 60 -60 o 60 -60 60 -60 o 90 o -90 o 90 o -90 o 90 o -90 o 200 Hz 0 30 o o o 250 Hz 0 -30 o o 315 Hz 0 -30 o o 30 o o 30 o o o -30 o 60 -60 o 60 -60 60 -60 o 90 o -90 o 90 o -90 o 90 o -90 o 8 400 Hz 500 Hz 630 Hz SPECIFICATIONS SSETM 10 Horizontal Polar Patterns 6 dB per Division 0 30 o o o 0 -30 o o 0 -30 o o 30 o o 30 o o -30 o 60 -60 o 60 -60 o 60 -60 o 90 o -90 o 90 o -90 o 90 o -90 o 800 Hz 0 30 o o o 1 kHz 0 -30 o o 1. 25 kHz 0 -30 o o 30 o o 30 o o -30 o 60 -60 o 60 -60 o 60 -60 o 90 o -90 o 90 o -90 o 90 o -90 o 1. 6 kHz 0 30 o o o 2 kHz 0 -30 o o 2. 5 kHz 0 -30 o o 30 o o 30 o o o -30 o 60 -60 o 60 -60 60 -60 o 90 o -90 o 90 o -90 o 90 o -90 o 3. 15 kHz 0 30 o o o 4 kHz 0 o o 5 kHz 0 -30 o o -30 30 o o 30 o o o -30 o 60 -60 o 60 -60 60 -60 o 90 o -90 o 90 o -90 o 90 o -90 o 6. 3 kHz 8 kHz 10 kHz 9 Horizontal Polar Patterns 6 dB per Division 0 30 o o o 0 -30 o o 30 o o -30 o 60 -60 o 60 -60 o 90 o -90 o 90 o -90 o 12. 5 kHz 16 kHz 10 SPECIFICATIONS SSETM 10 Input Plate 11 www. sanctuary-series. com 80305310 Features and specifications subject to change without notice. Peavey Electronics Corporation 711 A Street Meridian, MS 39301 (601) 483-5365 FAX (601) 486-1278 ©2004 Printed in the U. S. A. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PEAVEY SANCTUARY SSE 10

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PEAVEY SANCTUARY SSE 10 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag