User manual PENTAX V-325

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PENTAX V-325. We hope that this PENTAX V-325 user guide will be useful to you.

Lastmanuals help download the user guide PENTAX V-325.


Mode d'emploi PENTAX V-325
Download

You may also download the following manuals related to this product:

   PENTAX V-325 BROCHURE (448 ko)
   PENTAX V-325 POWERTOPOLITE (5517 ko)
   PENTAX V-325 QUICK REFERENCE GUIDE (32897 ko)

Manual abstract: user guide PENTAX V-325

Detailed instructions for use are in the User's Guide.

[. . . ] V-300 V-325 | V-325N | V-335N | V-323N TOTAL STATION SERIES INSTRUCTION MANUAL V-300 SERIES Basic Procedures PENTAX Industrial Instruments Co. , Ltd. 2-36-9, Maeno-cho Itabashi-ku, Tokyo 174-0063 Japan Tel. +81 3 3960 0502 Fax +81 3 3960 0509 E-mail: international@piic. pentax. co. jp Website: www. pentaxsurveying. com CONTENTS General Precautions regarding safety Warning Usage Precautions 1 Basic Operation 1. 1 Names of parts 1. 2 Unpacking and packing 1. 3 Standard equipment 1. 4 How to charge the battery 2 Display and Keyboard 2. 1 Display and keyboard 2. 2 Operation key 2. 3 Function Key 2. 4 Alphanumeric input 2. 5 Laser pointer 3 Preparation for Surveying 3. 1 Centring and Levelling of the Instrument 3. 2 Optical plummet 3. 3 Levelling with circular vial 3. 4 Levelling with the plate vial 3. 5 Eyepiece adjustment 3. 6 Target sighting 3. 7 Attachment and detachment of tribrach 4 Turning the Power On 4. 1 Turning the power on and off 4. 2 Adjusting LCD contrast 4. 3 Adjusting illumination brightness 4. 4 Adjusting reticle illumination 5 Angle Measurement 5. 1 Measuring an angle 5. 2 Resetting the horizontal angle to 0 5. 3 Holding the horizontal angle 5. 4 Inputting an arbitrary horizontal angle 5. 5 Displaying the % slope of the vertical angle 5. 6 Changing the horizontal angle from clockwise to counterclockwise 6 Distance Measurement 6. 1 Target setting 6. 2 Distance measurement 6. 3 Quick Mode 4 4 6 8 8 9 10 10 12 12 12 13 15 15 16 16 16 17 17 17 18 19 20 20 20 21 21 22 22 22 23 23 24 25 26 26 27 28 >> 2 CONTENTS >> 7 Correction Mode 7. 1 Changing the target constant 7. 2 Changing the temperature 7. 3 Changing the atmospheric pressure 7. 4 Changing the ppm value 8 Initial Setting 8. 1 Overview 8. 2 Entering the mode for initial setting 1 8. 3 Entering the mode for initial setting 2 8. 4 Entering the mode for initial setting 4 8. 5 Entering the mode for initial setting 5 8. 6 Example of changing an initial setting content (selection of atmospheric correction) 8. 7 Initial setting 1 8. 8 Initial setting 2 8. 9 Initial setting 4 8. 10 Initial setting 5 9 Accessing the Functions 9. 1 Accessing by help key 9. 2 Accessing by 007 10 Data Collector 11 Checks and Ajustments 11. 1 Plate Level 11. 2 Circular Vial 11. 3 Vertical reticle 11. 4 Perpendicularity of line of sight to horizontal axis 11. 5 Vertical 0 point error 11. 6 Optical plummet 11. 7 Offset constant 11. 8 The EDM beam axis 12 Appendix 12. 1 Warning and Error Messages 12. 2 Atmospheric Correction 12. 3 Calculation Formula 12. 4 Distance Range 12. 5 Specifications 12. 6 Notice to the user of this product 12. 7 Labelling 28 28 29 30 31 33 33 33 33 34 34 35 35 36 38 38 40 40 40 41 41 41 42 42 43 44 44 45 45 46 46 47 47 49 50 51 52 3 PRECAUTIONS REGARDING SAFETY Safety precautions (Must be followed) The following items are intended to prevent possible injury to the user or other people and/or damage to the instrument before it occurs. These safety precautions are important to the safe operation of this product and should be observed at all times. Distinctive displays The following displays are used to distinguish precautions by the degree of injury or damage that may result if the precaution is ignored. WARNING Items indicated by this sign are precautions which, if ignored, would result in serious injury. CAUTION Items indicated by this sign are precautions which if ignored may result in injury or material damage. · Here "injury" refers to injuries such as cuts, burns or electric shock the treatment of which will not likely require hospitalization or long-term attention. [. . . ] · MEASURE SHOT means the distance measurement by the shot mode. · MEASURE CONT means the distance measurement by the continuous mode. · TRACK SHOT means the fast distance measurement by the shot mode. · TRACK CONT means the fast distance measurement by the continuous mode. Confirm the target constant before beginning the distance measurement. Example:"MEASURE SHOT" at primary MEAS (Factory default setting) Collimate the telescope at a target and press MODE A 15°C P0 the [F1] [MEAS] once to start measuring the distance. Once distance measurement has been started, H. angle 92° 30' 20" the distance measurement mark remains displayed. Upon reception of a reflected light from the target, V. dst. SHOT ((( ))) the instrument beeps and displays the MEAS TARGET 0 SET DISP MODE mark to start the shot measurement automatically. · If the instrument is in mode B, press the [F5] [MODE] to switch to mode A and press [F1] [MEAS]. · Pressing the [F1] [MEAS] after collimating the telescope at the prism starts shot distance measurement with the "MEAS" text blinking. Distance measurement is completed and the "MEAS" text stops blinking the moment the distance measured by shot measurement is displayed. During continuous measurement, the "MEAS" text keeps on blinking. Pressing the [F1] [MEAS] again terminates both distance measurement and blinking the "MEAS" text. · Pressing [F4] [DISP] cycles through the sets of display items:"H. angle/H. dst. /V. dst. " , "H. angle/V. angle/S. dst. " and "H. angle/V. angle/H. dst. /S. dst. /V. dst. " , · Pressing the [ESC] or [F2] [TARGET] or [F5] [MODE] during distance measurement stops it. · If the shot count for distance measurement has been set to 2 or more in "Initial Setting 2", the distance is measured for the specified number of times to display the averaged value. Example:"TRACK CONT" at second MEAS (Factory default setting) MODE A Collimate the telescope at a Target and press [F1] [MEAS] twice in succession H. angle to start measuring the distance, H. dst. upon reception of a reflected light from the V. dst. CONT target, the instrument beeps and displays MEAS TARGET the mark to start the TRACK distance measurement. 15°C P0 92° 30' 20" ((( ))) 0 SET DISP MODE 27 · If the instrument is in mode B, press [F5] [MODE] to switch to mode A and press [F1] [MEAS ] twice. · Pressing [F1] [MEAS] twice after collimating the telescope at the Target starts Continuous distance measurement at fast speed with the "MEAS" text blinking. It remains blinking during the measurement. If you press the [F1] [MEAS] again, Distance measurement is completed and the "MEAS" text stops blinking. · Pressing [F4] [DISP] cycles through the sets of display items:"H. angle/H. dst. /V. dst. " , "H. angle/V. angle/S. dst. " and "H. angle/V. angle/H. dst. /S. dst. /V. dst. " , · Pressing the [ESC] or [F2] [TARGET] or [F5] [MODE] during fast distance measurement stops it. 6. 3 Quick Mode · The Quick Mode is to shorten the initial measuring time using prism or reflector sheet. [. . . ] * EDM Measuring time varies according to distance to be measured and conditions of the environment. * Quick mode, which is effective only under Normal mode (1mm) setting, functions with Prism and Reflector Sheet. * Reflectorless: - The measurement range and accuracy of Reflectorless are based on the condition that laser beam is emitted perpendicular to the white side of the Kodak Gray Card. - The measurement range may be influenced by the shape of the target and its environment. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PENTAX V-325

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PENTAX V-325 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag