User manual PHILIPS VCM8120/00T

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PHILIPS VCM8120/00T. We hope that this PHILIPS VCM8120/00T user guide will be useful to you.

Lastmanuals help download the user guide PHILIPS VCM8120/00T.


Mode d'emploi PHILIPS VCM8120/00T
Download
Manual abstract: user guide PHILIPS VCM8120/00T

Detailed instructions for use are in the User's Guide.

[. . . ] The slave monitor can handle 1 camera in a stand-alone configuration. The camera has a standard camera mount allowing installation on, for example, a tripod or wall bracket. Power supply: The safe low voltage (16-32V _) for the camera and system accessory is supplied by the monitor through the system cable. If the length of the system cable is more than 200m/600ft a mains power adapter should be used to provide the camera power supply. [. . . ] For more detailed information about the installation and operation of the system monitor and accessories (optional) you should consult the monitor and/or accessory manuals. Remark: When the system configuration is altered, the system monitor needs to check and memorise the cameras and accessories connected to its inputs. This is done automatically when the power is switched on. Use the power switch to switch off, only operating the power save key is not sufficient. If switching off is impracticable, use the auto install option of the system monitor's install menu. Caution: Never touch the glass of the camera lens as this may cause damage. g 5 Camera position 1 Take the camera, system cable and monitor to the area you want to observe (with the monitor on site, you can check whether the camera covers the required area). Remark: For outdoor use protective camera housing has to be used to protect the camera from rain and snow. Connect the camera to the system monitor (1). Connect the system monitor to the mains (2). After about 30 seconds or when a key is pressed the camera image will appear on the monitor screen. 2 3 4 camera in slave 1 video audio in 2 3 4 max 24V 2A out power out VCR out aux out alarm gnd 3 1 2 CL 66610005_314A. AI 5 If necessary adjust contrast T/brightness ( and/or colour S (controls at the front of the monitor) to optimise the camera image. g 6 6 Hold the camera at the proposed installation position Check on the monitor whether the camera covers the required area (The best results are obtained when the camera is pointed slightly downwards and is not looking into a bright light source). Caution: Never touch the CCD sensor which is located at the inside of the camera. Only use clean, dry air to blow particles from the surface of the sensor. R< FA 2 > NEAR CL 66610005_312. AI · Mount the new lens by turning it clockwise onto the lens mount of the camera. 1 6 43 · · · Direct the camera at the object or area to be monitored (6). Tighten the knob (3) and screw (4) when the camera is in position. Adjust the focus ring (1) of the camera lens to obtain an optimal image sharpness. Remark: If an auto-iris lens is used, connect the auto-iris cable to the camera (5). R< FA > NEAR 5 CL 66610005_313. AI g 11 System cable For the interconnections between the system monitor and camera 25m/75ft system cable is supplied. For an optimum picture and sound quality you should always use 4-wire dual twisted-pair cable when extending the connection. The cable and plugs are available in the hobby and professional trade. Pay attention that the connectors are fixed to the cable corresponding to the figure. 45 4-5 2-3 2 34 5 2 34 5 2 3 2 3 45 4-5 2-3 CL 66610005_006. AI If the cable length between the monitor and camera is more than 200m/600ft a mains power adapter should be used (see accessories). Caution: The plugs used for the observation system have the same dimensions as standard telephone plugs. Never connect a telephone to the camera or system monitor. Tips for maintenance Cleaning You can clean the outside of the camera with a moist fluff-free cloth or shammy leather cloth. When cleaning the camera lens a special cleaning cloth should be used. [. . . ] When cleaning the camera lens a special cleaning cloth should be used. Do NOT use cleaning fluids based on alcohol, methylated spirit, ammonia, etc. . Never touch the glass of the camera lens to prevent its delicate coating from damaging. Avoid direct contact with water. g 12 Technical specifications (VCM8120/00T / VCM7178/00T) Pick-up element Pixel elements Resolution Gain control Lens Iris Light sensitivity 1/3" solid state CCD 512 (H) x 582 (V), PAL interlaced 330 TVL automatic, 20dB See: Using a different lens Electronic iris When connected, an auto-iris lens overrides the electronic iris. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PHILIPS VCM8120/00T

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PHILIPS VCM8120/00T will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag