User manual PORT DESIGNS NETBAG NYLON BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PORT DESIGNS NETBAG NYLON. We hope that this PORT DESIGNS NETBAG NYLON user guide will be useful to you.

Lastmanuals help download the user guide PORT DESIGNS NETBAG NYLON.


Mode d'emploi PORT DESIGNS NETBAG NYLON
Download
Manual abstract: user guide PORT DESIGNS NETBAG NYLONBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] Check for : - PCB with Eeprom circuit. HE dE dF Invalid door state for more than 256 milliseconds bE2 Invalid state of key circuit short for 30 secs FE Invalid power source Frequency 2E Electronic Control Problem (OverVoltageError) Electronic Control Problem (CommunicationError) Invalid state of Eeprom communication AE Et 2 (Technical)NETBAG NYLON-02365D-02. indd 2 2011-07-08 5:35:57 ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. TEST MODE Service Mode (DV431 only) How to enter: To enter Service Mode , press Mixed Load Bell + Temp. Keys 3 seconds in normal mode until it sends out a beeping sound. Keys in Service mode , it will return Normal mode. Even though entering Service mode, the operating cycle will not be influenced. DR Ready Modem Wire Test(DV431AS* only) How to enter: After entering Service Mode, press the Wrinkle Prevent button to start the Wire Test. [. . . ] If a problem occurs, the "AE3" error code is displayed. Touch Sensor Data Display Mode Definition of Sensor Bar Touch Data Mode: This mode is default mode of entering service mode. How to enter: WithPowerOnpressingMixedLoadBell+Temp(DV431)orWrinklePrevent+Temp(DV231) for 3 seconds. This action will put the dryer into sensor bar touch data mode Dryer will display Sensor Bar data. Cycle Count Mode Definition of Sensor Bar Touch Data Mode: This mode is to bring up the total number of cycles that User have carried out. How to enter: - PresstheMixedLoadBell(DV431)orTime(DV231)keyinServiceMode. Software Revision Mode Definition of Software Version Mode: It is to retrieve its software version How to enter: At Service Mode, press Temp until it sends out a beeping sound ex) In case of "U1 05", U1 means major version "U1", 05 means minor version "05". If press Temp key In Software Version Mode, it will return Service Mode. 3 (Technical)NETBAG NYLON-02365D-02. indd 3 2011-07-08 5:35:57 ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. Continuous Run Mode Power On state (Normal user mode) Mixed Load Bell +Dry Level(DV431) or Wrinkle Prevent + Time(DV231) 7 SEC Continuous Run Mode How to enter: - - - - PressMixedLoadBell+DryLevel(DV431)orWrinklePrevent+Time(DV231)for7secduring PowerOnState(normalusermode). Once in Continuous Run Mode, display "CC" for 1 sec and the remaining time for 2 sec in turns. ThepreviouscyclewillrestartduringContinuousRunModeuntilthemodeisdeactivated. DuringContinuousRunMode, pressMixedLoadBell+DryLevel(DV431)orWrinklePrevent+ Time(DV231)for7secondstogobacktonormalusermode. Data Display Mode (DV431 only) How to Enter: - WithPowerOn, pressAdjustUpKey+AdjsutDownKeyfor7secondsuntilitsendsouta beeping sound . If not pressed any keys for 5 minutes, it will be set back from Data Display Mode If pressing AdjustUp Key in this mode , Display Mode ID will be incresed. If pressing AdjustDown Key in this mode , Display Mode ID will be decresed. Definition of Software Version Mode: Display Mode 0 : Temperature data Display Mode 1 : Average Touch Sensor data for 1 minute Display Mode 2 : Average Temperature data for 1 minute 4 (Technical)NETBAG NYLON-02365D-02. indd 4 2011-07-08 5:35:57 ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. TROUBLE DIAGNOSIS As the micom dry machine is configured of the complicate structure, there might be the service call. · Exhaust too long, too many elbows, flex ductwork installed. Improper drying · Poor intake air available for the dryer. clothes wrinkled 11 Rough texture long · Incorrect tumbler speed. dry time · Blower impeller bound; check for foreign material in blower area. · Check clothing labels for fabric content and cycle selected. · Clothes too wet due to insufficient spin out by washer. · ThumpingCheckforloosetumblerbaffle, reartumblerroller(s) worn or misaligned, out-of-round tumbler or high weld seam on tumbler. · Ticking Check for loose wire harness or object caught in blower wheel area. Noisy and/Or 12 · Scraping Check for front or rear bulkhead felt seal out of Vibration position or worn tumbler front bearings. · RoaringCheckforblowerwheelrubbingonblowerhousingor bad motor bearings. 7 (Technical)NETBAG NYLON-02365D-02. indd 7 2011-07-08 5:35:57 TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. COMPONENT TESTING PROCEDURES Component Electrical Testing (with ohmmeter) Thermistorresistance10K@25°C77°F Thermostat 1 resistance < 1 Belt Cut-off S/W -Leveropen:Resistancevalue<1 -Leverpush:Resistancevalue: Thermostat 3 resistance < 1 - If resistance is infinity, replace thermostat 3. [. . . ] Heater resistance 10 - If resistance is infinity, replace Heater. Lampresistance80~100(Violet&gray) Thermostat 3 Thermostat 2 Heater 160 °C, 25A thermal cut-off 127/99 °C, 25A Hi-limit 240V/5300W Motor(Electronic&GAS) Contacts Function Start Run 1M 2M 3M 5M 6M 1) 2) Measure resistance of the following terminal Door switch : open Terminal : "COM" - "NC" (1-3) < 1 Terminal : "COM" - "NO" (1-2) : Doorswitchpush:On Terminal : "COM" - "NC" (1-3) : Terminal : "COM" - "NO" (1-2) < 1 = Contact closed Centrifugal Switch (Motor) 2. 88 between Pin# 3 and 4 3. 5 between Pin# 4 and 5 8 (Technical)NETBAG NYLON-02365D-02. indd 8 2011-07-08 5:36:01 TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. GAS MODEL Radiant Sensor(10RS) Resistancevalue<1 Ifresistanceisinfinite, replaceRadiantsensor Gas Valve(25M01A) Valve1-2:Resistancevalue1. 2K Valve1-3:Resistancevalue0. 5K Valve4-5:Resistancevalue1. 2K If resistance is infinity, replace Valve Igniter(101D) Resistancevalue40~400 If resistance is infinite, replace Igniter Thermostat (60T21 Hi-Limit)230F-50F Resistancevalue<1 If resistance is infinity, replace Thermostat 9 (Technical)NETBAG NYLON-02365D-02. indd 9 2011-07-08 5:36:02 TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. RY7 Sensor Bars & temperature sensor check Sensor Bars - Disconnect harness and test Pink wirePin4toOrangewirePin5. Approxwithoutlaundry Approx190±10%withwetclothes Cycling Thermistor - Disconnect harness and test BluewirePin2toRedwirePin6. Approx10Kat25°C/77°F 10 (Technical)NETBAG NYLON-02365D-02. indd 10 2011-07-08 5:36:08 TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. 3-WIRE system connections A. External ground connector Neutral grounding wire (green/yellow) Center silver-colored terminal block screw Neutral wire (white or center wire) ¾" (1. 9 cm) UL-listed strain relief 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PORT DESIGNS NETBAG NYLON

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PORT DESIGNS NETBAG NYLON will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag