User manual POWTRAN PI8100

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual POWTRAN PI8100. We hope that this POWTRAN PI8100 user guide will be useful to you.

Lastmanuals help download the user guide POWTRAN PI8100.


Mode d'emploi POWTRAN PI8100
Download
Manual abstract: user guide POWTRAN PI8100

Detailed instructions for use are in the User's Guide.

[. . . ] Foreword Thank you very much for purchasing PI8000, PI8100 Family Frequency Inverters. This family is designed based on the experience of POWTRAN Company in the professional manufacture and sale of the products, and suitable for general-purpose machine, fan/pump drive, medium frequency drive and heavy load machine. This product adopts the advanced sensorless vector control technology, combined with China local frequency invenrter application features to achieve high-performance V/F control (dead-time compensation + auto-torque upgrade + Slip Compensation) and high-performance non-sense vector control, and high-performance speed sensorless vector control. This product adopts the advanced sensorless vector control technology, combined with the application of inverter technology in China features to achieve high-performance V/F control (dead-time compensation + auto-torque upgrade + Slip Compensation) and high-performance non-sense vector control, and high-performance speed sensorless vector control. This User's Manual includes PI8000/PI8100, the general purpose control and special purpose control . [. . . ] 1: the valid time of the output signal10ms, when reach this count, fixed keep the output status valid 10ms. 2: the valid time of the output signal 100ms, when reach this count, fixed keep the output status valid 100ms. 3: the valid time of the output signal 500ms, when reach this count, fixed keep the output status When the pulse signal of the input terminal satisfy with the preset condition, Yi terminal output the corresponding indication. 1 Selection of Input terminal DiXX=1~8 Input terminal is set to "pulse count input ", and set o54o55. Input terminal is set to "pulse counter clear", after terminal works, counter is cleared. Input terminal is set to "upload of pulse count value", after terminal works, counter uploads preset count value. Input terminal is set to"upload of upper count value", after terminal works, counter uploads the upper count value. 2 Selection of Output Terminal o21~o24 o21set the arrival of preset count, the effective time of output signal after reaching up count value is set by o51. o22 set the arrival of up count value, the effective time of output signal after arriving at the upper count value is set by o51. Frequency range of counting pulse signal: 0~100Hz. Virtual Terminal o56 0000~F7FF 0000 Y Effective Selection This parameter is used to select a terminal whether each virtual terminal functionality is valid. 2222222222222222 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 O4 O3 O2 O1 leave unused 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 AI3 AI2 AI1 DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 67 68 Section V Parameter Function Table Setting 0~10 0 1 o57 o58 o59 o60 DI1~4 Terminal Status DI5~8 Terminal Status AI1~3 Terminal Status O1~4 Terminal Status Virtual terminal valid choose Actual input terminal valid Virtual input terminal valid 0000~1111 0000~1111 000~111 0000~1111 Y Y Y Y Section V Parameter Function Table Actual frequency Actual current Output voltage Bus voltage IGBT temperature Output power Output torque Actual torque value 2 3 4 5 6 7 8 9 0~Max frequency 0~200%, corresponding paramerter: S03 output current percentage 0~200%, correlation parameter: b02b15 motor rated voltage 0~1000V DC voltage 0~100. 0 0~200% 0~Max torque 0~200% torque Boot time Running timing 10Bit 100Bit 1000Bit Reserved Reserved Reserved 0 1 0000 0000 Y Y Make the actual terminal can only be effective check terminal state. Make the Virtual terminal can only be effective through register check terminal state. No action Set frequency Actual frequency Actual current o61 o62 PL1 Pulse Output PL2 Pulse Output Output voltage DC bus voltage IGBT temperature Output power Output rpm Actual torque o63 o64 SPA pulse output ratio SPB pulse output ratio 1~1000 1~1000 0 1 2 3 4 5 6 7 8 9 1 1 Y Y 0 0 Y Y o65 o66 Limit time 1 configuration Limit time 2 configuration 1 Bit Section V Section V 1 Bit: Timing mode 0 Boot time , timing of runnig and breaking 1 Running timingonly timing of running 10 BitReserved 100 BitReserved 1000 BitReserved o67 o68 Limit Time 1 Limit Time 2 0. 0~3200. 0 0. 0~3200. 0 s s 2. 0 2. 0 Y Y SPA, SPB provide two isolated pulse output signal can be analogical multiple analog output signals. SPA, SPB provide high speed pulse output function. Set by o61~o64 and set functions valid when inverter power on again. SPA corresponding output signal 1, this function selected, o21 DO1 output action is invalid. SPB corresponding output signal 2, this function selected, o22 DO2 output action is invalid. Pulse output ratio = 1, output signal range 0 ~ 50hz. Maximum pulse output frequency 50 Khz, minimum frequency 1hz. for example Set timeing of limit time 1 , Time limit 2 Actual limit time on the basis of the set time multiplied by a run time multiple, such time multiple set by the ten bit of F49, refer to F49 instructions. 5-6. Multi-speed PLC Group:H00-H55(0x0300-0x0337) Code H00 Description / LCD Multi-speed Collocation 1 bit Setting Range Program running function cancel Program running function Direction decided by H40~H46 Direction decised by Terminal and keyboard Deceleration and acceleration time decised by H26~H39 0 1 0 1 Unit Factory Change Setting Limited 0000 Y SPA pulse output options = 2 SPA pulse output options = 10 Actual frequenciy ; The actual output pulse frequency = actual frequency / maximum frequency * 50hzx10. SPA pulse output options =3 Actual current SPB pulse output ratio=20 The actual output pulse frequency = actual current percentage 200*50hz*20 Output No action Set frequency Set Value 0 1 No output 0~Max frequency Output Signal Range Definition 10 bit 100 bit 0 69 70 Section V Parameter Function Table Time of acceleration and deceleration isdecided by terminal Running time decised by H18~H25 Running time decised by terminal Section V Parameter Function Table 10 bit: defining the start running of the Program 100 bit: Defines the end of the program period 1000 bit: Define effective time of the program output signal single-cycle 1 bit Continuous Cycle One-cycle command running The zero speed running when pause Fixed-speed running when the suspension Stop with the parameters set when stop Stop with the settings of start up Running at the speed when start up segment Running at the speed before the machine stopped 0 1 2 0 1 0 1 0 0000 Y 1 0 1 1000 bit 1 bit: Program running functions intelligent To use the program to run PLC functionality requires setting the bit to 1. Multi-segment speed run only need to set the corresponding multi-stage o36 ~ o46-speed switching can be used without the need to set this parameter. 0: Program running functions cancel 1: Program running function intelligent 10 bit: Define program runs or direction settings of multi-segment speed running 0: the direction decided by the H40 ~ H46 1: The directiondecided by the keyboard or terminal 100 bit:Define program runs or acceleration and deceleration time settings of multi-segment speed running 0: deceleration time decided by the H26 ~ H39 1: The acceleration and deceleration time determined by terminal 1000 bit: Set running time of defined program running 0: running-time decided by the H18 ~ H25 1: Running time decided by terminal 1 bit 10 bit 100 bit H01 Program Running Configuration 10 bit H02 Program Running Mode 100 bit Section V Section V 1000 bit 1 sequence control terminal control Program running start segment Program running end segment Output signal valid time 8ms Output signal valid time 20ms Output signal valid time 100ms Output signal valid time 500ms 0 1 0~15 0~15 0 1 2 3 0710 Y 1 bit: Running cycle 0: single cycle 1continuous cycle 2: Single cycle, running according to H01 speed of the end, stop after accepted the stopped orders. [. . . ] Inverter will confirm the number of the running pumps according to the requirement of the pressure close loop control. In the set range, only one pump is controlled by the inverter at the same time. If the timing shift interval time is set 0. 05~100. 00, when the related running time is stable, inverter inverter will shift up the pumps according to stop first or open first to ensure each pump has the chance to run and avoid the pump rusted because of long time N use. After the pumps run to the upper and lower, arrive the adding pumps or reducing pumps time, inverter will add or redcue the pumps according to stop first or open first to ensure each pump can run and avoid the pump rusted because of long time N use. IV-2-8. Soft-start pump control mode Set the soft start pump by E12 and through the input terminals o36 ~ o46, respectively controlled soft-start pump start and stop. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE POWTRAN PI8100

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual POWTRAN PI8100 will begin.