User manual PRISM SOUND DSCOPE SERIES III DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PRISM SOUND DSCOPE SERIES III. We hope that this PRISM SOUND DSCOPE SERIES III user guide will be useful to you.

Lastmanuals help download the user guide PRISM SOUND DSCOPE SERIES III.


Mode d'emploi PRISM SOUND DSCOPE SERIES III
Download
Manual abstract: user guide PRISM SOUND DSCOPE SERIES IIIDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] <5Hz to maximum of input domain; see Input sections below. ±fs/2^24, or approximately ±0. 005Hz at fs=96kHz. 0. 1º Amplitude range, accuracy: Frequency range: Frequency accuracy: Frequency resolution: Signal Analyzer Channels: Amplitude range, accuracy: Frequency range: Frequency accuracy: Phase accuracy: Phase resolution: © 2003-2007 Prism Media Products Ltd 1. 1 Prism Sound dScope Series III Continuous-Time Analyzer Channels: Functions: Amplitude range, accuracy: Frequency range: High-pass filters: Low-pass filters: Weighting filters: BP/BR filters: Measurement rates: Responses: FFT Analyzer Channels: Functions: Specifications Continuously-reading multi-function detector Two, single selectable measurement function. Revision 1. 21 Amplitude, balance, band pass, band reject, cross-talk, gain, IMD CCIF, IMD SMPTE/DIN, noise, THD+N, user-scripted. Determined by selected input domain; see Input sections below. [. . . ] fs=48kHz: +0. 05/-0. 1dB: DC. . 20kHz; +0. 1/­3dB: DC. . 22. 75kHz; fs=96kHz: ±0. 05dB: DC. . 20kHz; +0. 05/­0. 1dB: DC. . 40kHz; +0. 1/­3dB: DC. . 45. 5kHz; fs=192kHz: ±0. 05dB: DC. . 20kHz; +0. 05/­0. 1dB: DC. . 40kHz; +0. 1/­3dB: DC. . 91kHz. 10Hz. . 5kHz: ±0. 5º, 5kHz. . 20kHz: ±1. 0º, 20kHz. . 50kHz: ±2. 0º. 1kHz: <130dB; 15kHz: <120dB, typically (22Hz­22kHz): <140dB. XLR or coaxial BNC (RCA adapters provided), maximum current 150mA, minimum load 150R. Balanced (normal or CM test): 50R, 150/200R (jumper), 600R or asymmetric 25R/600R; unbalanced: 25R or 600R. Switchable floating or chassis. Amplitude accuracy: Frequency range: Residual THD+N: Residual noise: Flatness (1kHz ref): Phase matching: DC offset: Interchannel cross-talk: Output connectors: Output impedance: Grounding: © 2003-2007 Prism Media Products Ltd 1. 3 Prism Sound dScope Series III Analogue Inputs Channels: Sample rate (fs): Maximum amplitude: Amplitude accuracy: Frequency range: Residual THD+N: Residual noise: Flatness (1kHz ref): Specifications Revision 1. 21 Two, independent. <1Hz. . 0. 49fs (94kHz at fs=192kHz, 47kHz at fs=96kHz, 23. 5kHz at fs=48kHz); DC coupling by jumper. (fs=96kHz, 1kHz, 22Hz. . 22kHz filters, unweighted, RMS): <­105dB (0. 00056%)+1. 5uV, typical ­108dB (0. 00040%)+1. 3uV. (fs=96kHz, 22Hz. . 22kHz filters, unweighted, RMS): <­115dBu (<1. 4uV). fs=48kHz: ±0. 05dB: 5Hz. . 22. 3kHz; +0. 05/­0. 1dB: 4Hz. . 22. 5kHz; +0. 1/­3dB: 1. 5Hz. . 23. 5kHz; fs=96kHz: ±0. 05dB: 5Hz. . 44. 7kHz; +0. 05/­0. 1dB: 4Hz. . 45kHz; +0. 1/­3dB: 1. 5Hz. . 47kHz;fs=192kHz: ±0. 05dB: 5Hz. . 89. 5kHz; +0. 05/­0. 1dB: 4Hz. . 90kHz; +0. 1/­3dB: 1. 5Hz. . 94kHz. 10Hz. . 5kHz: ±0. 5º, 5kHz. . 20kHz: ±1. 0º, 20kHz. . 50kHz: ±2. 0º. DC blocked: <0. 0001% of range, DC coupled: <2% of range. 1kHz: <130dB; 15kHz: <120dB, typically (22Hz­22kHz): <140dB . XLR or coaxial BNC (balanced and unbalanced RCA adapters provided), demodulated digital input jitter, or direct from generator. 100kR, 600R or 150/200R (jumper), maximum 1W. (20Hz. . 20kHz): >80dB. Phase accuracy: DC offset: Interchannel cross-talk: Input sources: Input impedance: Small-signal CMRR: © 2003-2007 Prism Media Products Ltd 1. 4 Prism Sound dScope Series III Digital Outputs (data) Channels: Sample rate (fs): Sample rate accuracy: Sample rate deviation: Wordlength: Dither: DC offset: Frequency range: Residual THD+N: Flatness (1kHz ref): Phase matching: Channel Check mode: Specifications Revision 1. 21 Two in normal (one-wire) mode, independent muting; one in Split96 (two-wire) mode. 32kHz, 44. 1kHz, 48kHz, 88. 2kHz*, 96kHz*, 176. 4kHz*, 192kHz* [*Generated normal or Split96]. User-defined, added to signal, 48-bit resolution. (1kHz, 24 bits, FS, 22Hz. . 22kHz bandwidth, unweighted, RMS): <­140dB (<0. 00001%). Generates data integrity sequence (PRBS) in 24, 20 or 16 bit wordlength which can be checked at digital input, or by Prism Sound DSA­1 hand-held analyzer. Professional or Consumer modes; all fields functionally or numerically settable for each channel (tied or split), with automatic options. Can generates EUT transparency check sequence. [. . . ] Range: 40mV to 20. 48Vp­p; accuracy: (XLR) ±5%+40mV, (BNC) ±5%+20mV; resolution: 5mV. (fs jitter mode): freq range: 700Hz. . fs/2, max amplitude 0. 5UIp­p; (data jitter mode): freq range 700Hz. . 64fs, max amplitude 0. 5UIp­p. Response: p­p; accuracy: ±5%+2ns; resolution: <300ps. (fs jitter mode): freq range: 700Hz. . fs/2, max amplitude 64UIp­p; (data jitter mode): freq range 700Hz. . 48kHzs, max amplitude 0. 5UIp­p. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PRISM SOUND DSCOPE SERIES III

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PRISM SOUND DSCOPE SERIES III will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag