User manual QSC AUDIO RAVE 520AZ

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual QSC AUDIO RAVE 520AZ. We hope that this QSC AUDIO RAVE 520AZ user guide will be useful to you.

Lastmanuals help download the user guide QSC AUDIO RAVE 520AZ.


Mode d'emploi QSC AUDIO RAVE 520AZ
Download
Manual abstract: user guide QSC AUDIO RAVE 520AZ

Detailed instructions for use are in the User's Guide.

[. . . ] RAVE 520az 8 input CobraNet Enabled Signal Processor Hardware Manual *TD-000153-00* TD-000153-00 rev. A IMPORTANT SAFETY PRECAUTIONS & EXPLANATION OF SYMBOLS The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous" voltage within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to humans. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in this manual. SAFEGAURDS Electrical energy can perform many useful functions. This unit has been engineered and manufactured to assure your personal safety. [. . . ] Connect to an available COM port on your PC and communicate using a terminal control program such as Windows Hyperterminal. Use a normal serial data cable with a DB-9 male plug to connect to the RAVE 520az. To connect the cable, orient the connector properly, then push into the receptacle until it is firmly seated; tighten the retaining screws "finger tight". Communications should be 9600 baud, no parity, 8 data bits, 1 stop bit, and flow control Xon/Xoff. LED Indicators When the RAVE 520az is plugged into a properly functioning AC outlet, it will power up and briefly display a welcome screen on the LCD display. POWER Indicator- This blue indicator illuminates when the RAVE 520az is plugged into a properly functioning AC source. There is no power switch on the RAVE 520az. This helps to prevent accidental system shutdowns. DIAGNOSTIC Indicator- This red indicator illuminates during the power-on self test, then should extinguish. If it remains illuminated, this indicates that the self-test has detected an unexpected event, such as corrupted firmware or a memory boot failure. If the DIAGNOSTIC LED remains illuminated, try resetting the RAVE 520az by cycling power off and on once. Should the indication persist, contact QSC's Technical Services for guidance. During operation, any system fault will fully illuminate the indicator. During a "flash" update, the indicator will blink on and off; this is normal. Any error detected will be displayed on the LCD. For purpose of unit identification, the LED can be remotely turned on using QSControl. net software. (continued, next page) 15 LED Indicators (continued) QSControl and CobraNet Network Status (Port) Indicators- There is a group of LEDs on the front and rear panels labeled RX, TX and LINK. One group is for the QSControl network port and the other for the CobraNet network port. Note: Port indicators on rear panel are color coded to match the corresponding color-ring around the QSControl and CobraNet RJ45s. RX (receive)- This indicator illuminates any time the RAVE 520az receives data from the corresponding network. TX (transmit)- This indicator illuminates whenever the RAVE 520az transmits data onto the corresponding network. LINK STATUS- The corresponding indicator illuminates when the RAVE 520az is connected to an operating network. LCD Display and Controls The RAVE 520az has a 2 line X 16 character LCD display. The display and the multi-function push-button switches on either side provide data access and editing capability. The push-button switches on either side of the display are used to navigate through the menus. [. . . ] "Euro Style") detachable terminal blocks Electromechanical Relay 1:NC 2:NO 3: COM 1A 30VDC 4 discrete outputs 2-pin "Phoenix Style" (a. k. a. "Euro Style") detachable terminal blocks Single-ended, TTL compatible 1:+(Signal) 2:-(CHASSIS GND) 6 discrete inputs for TTL logic, voltage control or passive resistive 2-pin "Phoenix Style" (a. k. a. "Euro Style") detachable terminal blocks Single-ended, ground referenced 1:+(Signal) 2:-(CHASSIS GND) Reads signals between 0-5V nominally Use 10K for full range +/- 48V 0. 5mA with 10K pot (for passive resistive controls) Female DB9 Connector Neutrik Ethercon RJ45 Ruggedized Data Connector Neutrik Ethercon RJ45 Ruggedized Data Connector Yellow Link, Tx, Rx, front panel / Green Link, Tx, Rx, rear panel Yellow Link, TX, RX, front and rear panel Blue, front panel Red, front panel 2 line x 16 character, backlit, front panel Specifications are subject to change without notice. 25 How to Contact QSC Audio Products Mailing address: QSC Audio Products, Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE QSC AUDIO RAVE 520AZ

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual QSC AUDIO RAVE 520AZ will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag