User manual QUADRA FIRE 839-1290

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual QUADRA FIRE 839-1290. We hope that this QUADRA FIRE 839-1290 user guide will be useful to you.

Lastmanuals help download the user guide QUADRA FIRE 839-1290.


Mode d'emploi QUADRA FIRE 839-1290
Download
Manual abstract: user guide QUADRA FIRE 839-1290

Detailed instructions for use are in the User's Guide.

[. . . ] R Tested and Listed by O-T L C US Portland Oregon USA TOPAZ DIRECT VENT ROOM HEATER OMNI-Test Laboratories, Inc. Owner's Manual Installation and Operation Model: 839-1290 839-1320 839-1340 844-4120 TOPAZ-D-CSB TOPAZ-D-CWL Quartet Front Solitaire Front CAUTION DO NOT DISCARD THIS MANUAL · Important operating and · Read, understand and · Leave this manual with follow these instructions maintenance instructions party responsible for use for safe installation and included. operation. D DI O N SC O AR T D WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death. · Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. · What to do if you smell gas - Do not try to light any appliance. - Immediately call your gas supplier from a neighbor's phone. [. . . ] If the flashing is larger than the top of the chimney, cut and fold flashing as needed to fit chimney (Figure 5. 26). Step 7. If additional lengths of flex liner are needed to span the chimney height, use a flex coupler to connect the pieces of flex liner together. Connect the flex to the coupler by using four sheet metal screws for each side (Figure 5. 27, on the next page). September 1, 2008 Quadra-Fire · Topaz · 7009-113G Page 21 Flex Liner 6 in. (152mm) diameter opening in masonry wall Flex Coupler Sheet Metal Screws Retro Connector Figure 5. 27 Figure 5. 29 (3) Masonry Bolts (Not included) Step 8. Use three sheet metal screws through the side of the top adapter into the flange on the flashing (Figure 5. 28). Twist lock the high wind termination cap on to the top adapter. High Wind Termination Cap Step 10. Slide wall thimble cover over retro connector and secure with masonry bolts (Figure 5. 30). If you have a framed wall in front of the masonry, use wood screws to mount wall thimble cover to framed wall, over retro connector and 10 in. (254mm) square framed opening (Figure 5. 25, on page 21). If needed, add a section of direct vent pipe to the retro connector in order to extend through the opening in the wall thimble cover. Top Adaptor (3) Sheet Metal Screws Retro Connector Wall Thimble Cover (4) Masonry Bolts (Not included) Flashing Figure 5. 28 Figure 5. 30 Step 9. Use three sheet metal screws to attach the flex liner to the connector (Figure 5. 29). Mount the retro connector to the masonry wall using masonry bolts. Redrill larger holes on connector as needed. Be careful to ensure that the connector is centered in the opening and the mounting holes line up with the masonry wall. Step 11. The connection between the appliance and the retro connector may be completed with sections of direct vent pipe. Page 22 Quadra-Fire · Topaz · 7009-113G September 1, 2008 A. Fuel Conversions Before making gas connections ensure that the appliance being installed is compatible with the available gas type. Any natural or propane gas conversions necessary to meet the appliance and locality needs must be made by a qualified technician using Hearth & Home Technologies specified and approved parts. 3 screws 6 Gas Information 1. Converting to LP Gas NOTE: Gas conversions should only be performed by a qualified service person, and/or where required by state and local codes, licensed installer/service technician. In the Commonwealth of Massachusetts, installation must be performed by a licensed plumber or gas fitter. KIT CONTENTS: Replacement orifice; replacement pilot injector; and valve regulator. TOOLS REQUIRED: Power drill (a 90° handle is helpful); #2 Phillips bit; 5/32 in. open end wrench. Opens Left Closes Right Figure 6. 3 Remove the three screws on the front of the burner support. [. . . ] The maximum amount recoverable under this warranty is limited to the purchase price of the product. In no event shall HHT be liable for any incidental or consequential damages caused by defects in the product. Adjustments, regular maintenance, cleaning and temporary repairs, or the failure to duplicate the problem in the home is not covered under this warranty. This limited warranty does not extend to or include surface finish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, firebrick, pellet logs, kaowool or other ceramic insulating materials. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE QUADRA FIRE 839-1290

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual QUADRA FIRE 839-1290 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag