User manual RANE RP 228D DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual RANE RP 228D. We hope that this RANE RP 228D user guide will be useful to you.

Lastmanuals help download the user guide RANE RP 228D.


Mode d'emploi RANE RP 228D
Download

You may also download the following manuals related to this product:

   RANE RP 228D SCHEMA (302 ko)

Manual abstract: user guide RANE RP 228DDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] A recessed Default button on the rear panel recalls Memory 1 in case of computer failure. Each channel has 28 bands of 1/3-octave interpolating constant-Q filters for predictability and minimal interaction between bands. The boost/cut range is ±10 dB in 0. 5 dB steps. The digital filters are designed to match the previously available analog RPE 228. Additional low and high cut filters have a wide adjustment range (Low Cut to 200 Hz and High Cut to 1 kHz). [. . . ] These curves can then be sent to a unit or saved in a file. The software is operational even without an RPE 228d connected. The Rane RPD 1 may be used to control the RPE 228d from a remote location using a modem. The RPE 228d uses the same RW 232 commands as the RPE 228. The unit's firmware may be replaced with new versions, uploaded from a computer through the serial port. Interpolating Constant-Q Filters Low and Hi Cut Bandlimiting Filters 16 Non-Volatile Memories Separate Input & Output Level Controls Balanced Inputs & Cross-Coupled Outputs RaneWare® Windows® Software Firmware Updates via RW 232 UL/CSA/CE and 100/120/230 VAC Remote Power Supplies Windows is a registered trademark of Microsoft Corporation RaneWare is a registered trademark of Rane Corporation Data Sheet-1 Parameter Equalizer: Channels . . . . . . . . . . Bands . . . . . . . . . . Accuracy . . . . . . . . . . Range . . . . . . . . . . Step Size . . . . . . . . . . Memories Inputs: Type . . . . . . . . . . Connectors . . . . . . . . . . Impedance . . . . . . . . . . Maximum Level Outputs: Type . . . . . . . . . . Connectors . . . . . . . . . . Impedance . . . . . . . . . . Maximum Level Communications Interface . . . . . . . . . . Cable Length Overall Level Range RFI Filters Memory Bypass Switches Overload Indicator Thresholds Signal Present Thresholds Sweepable Low Cut Filter Sweepable High Cut Filter Frequency Response Throughput Delay THD+Noise Signal-to-Noise Ratio Dynamic Range Channel Separation Unit: Agency Listing . . . . . . . . . . 120 VAC Model Specification 2 (28) 1/3-Octave ISO Spacing 2 ±10 0. 5 16 Active Balanced Euroblock 25k +20 Active Cross-Coupled Balanced Euroblock 200 +20 (+17) RW 232 (RS-232) 50 ±12 Yes EEPROM and Flash Digitally Controlled 17 -27 10 Hz-200 Hz, 12 dB/Oct 1 kHz-20 kHz, 12 dB/Oct 20-22 kHz 1. 50 0. 02 0. 1 re +4 dBu 87 88 106 98 Class 2 Equipment UL CSA Certified FCC part 15J CE-EMC CE-Safety UL CSA CE-EMC CE-Safety Built to JIS 18 VAC w/ center tap 750 All Steel 1. 75" H x 19" W x 8. 5" D (1U) 6 lb (w/o power supply) 4. 5" x 20. 3" x 13. 75" 11 lb Limit Units 0. 25 % dB dB Conditions/Comments Interpolating Constant-Q 31. 5 Hz to 16 kHz Center frequency Plus current settings 1% 1 ohms dBu 1% 1 max 1 ohms dBu feet dB Balanced: 100 ohms each Output >2k ohms (>600 ohms) (15 meters maximum) 1 dB step size, Input or Output Nonvolatile Auto-Bypass upon power failure Input and Output levels Input level 10 Hz step size, 20% @ 10 Hz 1 kHz step size Cut Filters "Off" +4 dBu, 1 kHz +4 dBu, 20 Hz-20 kHz 20 kHz Noise BW, balanced All bands centered, unity gain* All bands full cut, unity gain* 20 Hz-22 kHz, A-weighted 1 kHz National Electrical Code Exempt Class 2 equipment Exempt Class 2 equipment Class B Device EMC Directive 89/336/EEC Exempt Article 1 of LVD 73/23/EEC File no. LR58948 EMC Directive 89/336/EEC LV Directive 73/23/EEC Japan only Rane RS 1 RMS current from remote supply (4. 4 cm x 48. 3 cm x 21. 6 cm) (2. 7 kg) (11. 5 cm x 52 cm x 35 cm) (5. 0 kg) *Level Controls Set at "0" 1 dBu 5 dBu 3% 3% +0/-1. 5 dB ms % % 2 2 2 3 dB dB dB dB . . . . . . . . . . 230 VAC Model Power Supply: Agency Listing . . . . . . . . . . 120 VAC Model . . . . . . . . . . 230 VAC Model . . . . . . . . . . 100 VAC model Power Supply: Requirement . . . . . . . . . . Maximum Current Unit: Construction . . . . . . . . . . Size . . . . . . . . . . Weight Shipping: Size . . . . . . . . . . Weight Note: 0 dBu=0. 775 Vrms 0. 1 Vrms mA Data Sheet-2 RPE 228d PROGRAMMABLE EQUALIZER Block Diagram RaneWare® Control Screens Data Sheet-3 RPE 228d PROGRAMMABLE EQUALIZER Rear Panel Memory Recall Port The Memory Recall Port provides contact closure control for the first eight preset memories. No computer is required after initial setup. There are nine terminals--one is chassis ground, and the other eight are for Memories 1-8. Momentary connection of one of these eight terminals to ground causes both channels of the unit to recall a preset Memory. Multiple units may be controlled by connecting these terminals in parallel. Either momentary or latching switches may be used. Use of a latching switch results in a Memory recall upon power-up. The latching switch should only close one contact at a time. The translation between the eight closures and the 16 Memories is programmable. Architectural Specifications The programmable digital equalizer shall consist of two channels, each with 28 bands spaced on ISO centers from 31. 5 Hz to 16 kHz, and be 1/3-octave wide, all as specified elsewhere. The amplitude control range of each band shall be +10 dB and -10 dB, adjustable in 0. 5 dB steps. Each channel shall have adjustable low-cut and high-cut filters. The low-cut filter range shall be 10 Hz to 200 Hz in 10 Hz steps, or OFF. The high-cut filter range shall be 1 kHz to 20 kHz in 1 kHz steps, or OFF. [. . . ] The unit shall have certified compliance with FCC docket 20780 Part 15J for Class B computing devices, and EMCD 89/336/EEC. The 120 VAC model shall be powered from a UL listed, CSA certified remote power supply, and the 230 VAC model shall be powered from a remote power supply meeting LVD 73/23/EEC & EMCD 89/336/EEC standards. The 100 VAC model shall be built to JIS for Japan. The chassis shall be constructed entirely from cold-rolled steel. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RANE RP 228D

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual RANE RP 228D will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag