User manual RAPID 65 ELECTRIC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual RAPID 65 ELECTRIC. We hope that this RAPID 65 ELECTRIC user guide will be useful to you.

Lastmanuals help download the user guide RAPID 65 ELECTRIC.


Mode d'emploi RAPID 65 ELECTRIC
Download
Manual abstract: user guide RAPID 65 ELECTRIC

Detailed instructions for use are in the User's Guide.

[. . . ] Especially for Lithium batteries, it can prevent the overcharging which may lead to an explosion due to the user's fault. It can disconnect the circuit automatically and alarm once detecting any malfunction. All the programs of this product were controlled through two way linkage and communication, to archive the maximum safety and minimize the trouble. All the settings can be configured by users! Internal independent Lithium battery balancer iMax 65 ELECTRIC employs an individual-cell-voltage voltage balancer. [. . . ] There are three kinds of Lithium battery: LiFe(3. 3V), Lilo(3. 6V) or LiPo(3. 7V). This information is of critical importance that you have to check the battery carefully to make sure it is set up correctly. If it is different from correct value, explosion can occur during charge process. To avoid from erroneous setting by users, iMax 65 ELECTRIC detects the cell count of Lithium battery automatically at the beginning of charge or discharge process. But battery that is deep-discharged can't be detected correctly. To avoid this error, the time term can be set to verify the cell count by the processor. Normally, 15 seconds are enough to detect the cell count correctly. You need to extend the time term limit for the battery of large capacity. But the charge or discharge process may come to an end within the time term because of the time limit decided by the wrong count if you set too long time limit for the battery of small capacity. You have to extend the time term if the processor detect the cell count incorrectly at the beginning of charge or discharge process. Otherwise, default value is recommended to use. In the balance mode, the battery needs to have a balance lead to connect to the individual port at the right side of the charger. And you need connect the battery's output plug to the output of charger. Charging in this mode is different from the normal modes, because the built-in processor monitors voltage of individual cell and control input current fed into each cell to normalize the voltage. The value on the left side of the second lines sets the charge current. The value on the right LiPo FAST CHG NiCd Sensitivity side of the second lines sets the D. Peak 11. 1V(3S) 2. 0A Default battery pack's voltage. After setting current and voltage, press STAR/ENTER for more -+ -+ than 3 seconds to start the DEC INC DEC INC process. Batt type Start Stop Enter `>3 seconds'This displays the number of cells you set up and the processor detects. "R" shows the number of R:3SER S:3SER cells detected by the charger and CONFIRM(ENTER) "S" is the number of cells set by you at the previous screen. If Start both numbers are identical you Enter can start charging by press START/ENTER button. If not, Li3S 2. 0A 12. 59V NiCd Sensitivity press BATT TYPE/STOP button to go back to previous screen to FAS 022:43 00682 D. Peak Default carefully check the number of cells of the battery pack before Current going ahead. Number Charging Suppiled voltage time capacity battery of This screen shows the real-time Charge cells status during charge process. [. . . ] Press BATT capacity TYPE/STOP key to end the program. Data storage program For your convenience, iMax 65 ELECTRIC has a data storage and load program. It can store five battery data representing the respective specifications of batteries. You can call back the data when charging or discharging without setting up the program again. Press START/ENTER key to make it blink, and use INC or DEC to set up the parameter. PROGRAM SELECT SAVE DATA Start Enter SAVE [01] NiMH 14. 4V 3000mAh Voltage Data Capacity Type of battery number Batt type Start `>3seconds' stop Enter Setting of the parameter in the screen will not affect the charge and discharge process. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RAPID 65 ELECTRIC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual RAPID 65 ELECTRIC will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag