User manual RAVENHEAT RSF 84E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual RAVENHEAT RSF 84E. We hope that this RAVENHEAT RSF 84E user guide will be useful to you.

Lastmanuals help download the user guide RAVENHEAT RSF 84E.


Mode d'emploi RAVENHEAT RSF 84E
Download
Manual abstract: user guide RAVENHEAT RSF 84E

Detailed instructions for use are in the User's Guide.

[. . . ] ELECTRONIC IGNITION - AUTOMATIC MODULATING BOILER FANNED COMBI RSF 84E - RSF IOOE RSF 84ET - RSF IOOET WITHOUTTIMER o RSF 84E G. C. No 47 581 25A NATURAL GAS (G 20) AND PROPANE (G 31) Tested, certified and service listed Listed by The United Kingdom Water Fitting Byelaws Scheme WITH TIMER RSF 84ET G. C. No 47 581 26A NATURAL GAS (G 20) AND PROPANE (G 31) INSTALLATION AND SERVICING INSTRUCTIONS TO BE LEFT WITH USER Technical and illustrative data are not binding and can be modified without prior notice. The descriptions and illustrations in the present booklet are for guideline purposes only. RAVENHEAT MANUFACTURING LTD. , CHARTISTS WAY, MORLEY, LEEDS, LS27 9ET. [. . . ] Use at least one bracket for each extension used. Ensure that all inner flue connections have a good fit/seal, and that the space clips in each extension are correctly positioned. 5. 8 5. 8. 1 REASSEMBLE BOILER AS PER (sect. 5. 6. 1) Fitting valves pack Remove plastic caps from boiler connection and fit flanged copper tail and valves as per Fig. 46) A minimum gas pressure of 20 mbar (8 in wg. ) must be available at the boiler inlet at full flow rate. Fit gas service cock to the boiler via the union nut and connect gas pipe. Do not overtighten and use another spanner as a counter force to avoid straining internal connections. 46) Before any central heating connections are made to the boiler all system valves should be opened and the system thoroughly flushed out with cold water. - Connect the central heating return pipe to the isolating cock marked CHR. - Connect the central heating flow pipe to the isolating cock marked CHF. - Pipe dimension's and position are marked on template supplied and Fig. 49A 5. 11 5. 11 . 1 DOMESTIC HOT WATER (Fig. 46) The domestic hot water circuit does not need a safety valve but it is essential to ensure that the pressure of the cold water supply does not exceed 10 bar. If in doubt it is advisable to install a pressure reducing valve. The minimum pressure needed to operate the domestic hot water system is 0. 5 bar with a flow of approx 3 Lts. The regulator screw on the cold water outlet of the diverter valve may be adjusted to prevent excess volume flow (Fig. Flush out all foreign matter from the supply pipe before connecting to the appliance. cold water pipe to the stop cock to the appliance inlet marked DCW. hot water pipe with a suitable connection. SAFETY VALVE DISCHARGE The safety valve is located near the pump. It has a threaded outlet RC l/2" (to 15 mm copper) to permit a discharge pipe to be connected. When connecting ensure the discharge pipe does not restrict access. [. . . ] Spacing Clips Spacing clips are available on request should they be required. Sampling point Sampling point is positioned on the outlet of the twin flue header for the use of sampling gas combustion products. Vertical eccentric flue exhaust duct Condensing trap To drain the exhaust pipe only with a greater distance of over 6 metres, a condensating trap must be fitted, or as an alternative to this the sampling point may also be used as a condensating drain should this be required. Exhaust/suction system with concentric pipes for flat or sloping roofs. Maximum distance D = I + E + T = 14 metre + 14 metre + 1 metre = 29 metre maximum (pipe + terminal). NOTE: The pressure loss for each elbow fitted is: 90" elbow less 4 metre of pipe length for each one fitted. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RAVENHEAT RSF 84E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual RAVENHEAT RSF 84E will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag