User manual RAYMARINE OPEN ARRAY SCANNERS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual RAYMARINE OPEN ARRAY SCANNERS. We hope that this RAYMARINE OPEN ARRAY SCANNERS user guide will be useful to you.

Lastmanuals help download the user guide RAYMARINE OPEN ARRAY SCANNERS.


Mode d'emploi RAYMARINE OPEN ARRAY SCANNERS
Download
Manual abstract: user guide RAYMARINE OPEN ARRAY SCANNERS

Detailed instructions for use are in the User's Guide.

[. . . ] Pathfinder Radar Scanners Owner's Handbook Document number: 81154_9 Date:September 2006 5 Pathfinder Radar Scanners Owners Handbook March 2004 Intended Use The scanner units detailed in this handbook form part of navigational radar systems intended for light marine use. These radar systems are only an aid to navigation. Safety Notices This radar equipment must be installed and operated in accordance with the instructions contained in this manual. Failure to do so can result in personal injury and/or navigational inaccuracies. The scanner unit contains high voltages. [. . . ] 12 V systems (4 kW scanners only) Extensions to the supplied power cable must be kept to a minimum and the power should be fed directly from the output of the battery isolator switch via its own dedicated cable system. It is recommended that no additional power switch is included in this power cable. CAUTION: The display unit does not include a fuse for scanner power, so an in-line fuse or circuit breaker MUST be included in the power cable. All power connections must be of high quality to minimize their resistance and to remove the risk of accidental shorts. Recommended maximum power cable extensions are given in the table below. These figures relate to the total cable extension, from the end of the supplied 1. 5 m power cable to the system battery terminals. Do not exceed these lengths as unreliable operation may result. cxcix Table 2-3: Max. Extension Power Cable Lengths (m), 12 V Systems 4 kW scanners Power Cable Core Size (each core) mm : 4. 0 AWG: 11 2 6. 0 10 4. 5 8. 0 8 6. 0 10. 0 7 7. 5 4 kW Scanners <3. 0 Note: If the required extension results in unacceptably large diameter cables, use two or more smaller gauge wires to achieve the required copper wire cross-section. For example, using two pairs of 2 mm2 is equivalent to using two single 4. 0 mm2 cables. 24 V and 32 V systems These systems are less sensitive than 12 V systems to voltage loss in the power cables. However, it is still necessary to use adequate cables to prevent excessive power loss. The table below gives the recommended wire gauge for different power cable extension lengths. Raymarine recommends that power is fed directly from the output of the battery isolator switch via its own dedicated cable system. CAUTION: The display unit does not include a fuse for scanner power, so an in-line fuse or circuit breaker MUST be included in the power cable. Note: If the required extension results in unacceptably large diameter cables, use two or more smaller gauge wires to achieve the required copper wire cross-section. For example, using two pairs of 2 mm2 is equivalent to using two single 4. 0 mm2 cables. Table 2-4: Max. Extension Power Cable Lengths (m), 24/32 V Systems 4 kW Scanners Power Cable Core Size (each core) mm : 2. 0 AWG: 14 2 4. 0 11 16. 0 6. 0 10 24 8. 0 8 32 10. 0 7 35 4 kW Scanners 8. 0 cc Table 2-5: Max. Extension Power Cable Lengths (m), 24 V Systems 10 kW Scanners Inter-Unit Cable(s) mm : 1. 5 AWG: 16 2 Power Cable Core (each core) 2. 0 15 16. 0 14. 0 12. 0 10. 0 8. 0 8. 0 6. 0 4. 0 2. 5 14 20. 0 18. 0 16. 0 13. 0 10. 0 10. 0 8. 0 5. 0 4. 0 11 32. 0 28. 0 24. 0 20. 0 16. 0 16. 0 12. 0 8. 0 5 m Heavy 10 m Heavy 15 m Heavy 15 m Heavy + 5 m ext 15 m Heavy + 10 m ext 25 m Heavy 25 m Heavy + 5 m ext 25 m Heavy + 10 m ext. 12. 0 10. 5 9. 0 7. 5 6. 0 6. 0 4. 5 3. 0 Table 2-6: Max. Extension Power Cable Lengths (m), 32 V Systems 10 kW Scanners Power Cable Core Size (each core) mm : 1. 5 AWG: 16 2 2. 0 15 20. 0 2. 5 14 25. 0 10 kW Scanners 15. 0 cci Open array scanner cables for C-series displays A split pedestal cable is required to connect a compatible open array scanner to the display unit and to the power source. If you are connecting an existing compatible scanner to a C-Series display a pedestal adaptor cable can be used instead of the split pedestal cable. CAUTION: Do not extend the split pedestal or pedestal adaptor cable. Split pedestal cable The split pedestal cable combines the inter-unit and power cores, divided by a Y junction. One core has a connector plug for connecting to the display unit, the other core is for connecting to power. The scanner end is prepared ready to fit to the power and signal connectors (see Section 2. 2). Two cable lengths are available: · 25m cable provides 25m from scanner to Y junction. [. . . ] Correction Check that the cable connecting the scanner to the radar display unit is firmly attached and undamaged. Check that the polarity of the cables is correct. The bearing displayed on the radar Perform the bearing alignment procedure display is not the same as the actual described in the display unit Owner's Handbook bearing Section 8. 7. The 72" antenna stops in the wrong Refer to 72" open array position alignment. position. ccxxvii Technical Support: Please visit out website at: www. raymarine. com/recreational/support where you will find a Questions & Answers database, service information and email access to the Technical Support department. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RAYMARINE OPEN ARRAY SCANNERS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual RAYMARINE OPEN ARRAY SCANNERS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag