If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual RESPONSE ALARMS SAC1. We hope that this RESPONSE ALARMS SAC1 user guide will be useful to you.

Lastmanuals help download the user guide RESPONSE ALARMS SAC1.


Mode d'emploi RESPONSE ALARMS SAC1
Download
Manual abstract: user guide RESPONSE ALARMS SAC1

Detailed instructions for use are in the User's Guide.

[. . . ] SA1/SA2/SAC1 Wirefree Alarm Systems 1 4 7 0 2 5 8 ON AIR 3 6 9 1 2 LOW BATT. Installation & Operating Manual FOREWORD The SA1, SA2 and SAC1 Wirefree Alarm Systems comply with the requirements of BS6799 Class 1 for Wireless Alarms. All components are designed and manufactured to provide a high standard of security protection and long, reliable service. In addition, the radio devices are tested and approved by the Radio Regulatory division of the Department of Trade and Industry (DTI) to ensure that they will not interfere with other radio equipment. No radio licence is required, however, the approved radio frequency is not protected from interference and may be withdrawn from use at any time subject to the DTI giving users an appropriate notice period. [. . . ] Do not over-tighten the fixing screws as this may damage the casing. 4. The PIR Detector incorporates an anti-false alarm feature designed to compensate for situations where the detector may be affected by environmental changes, (e. g. This feature is called "Pulse Count" and may be selected for 1 or 2 pulse detection. The recommended setting is for 1 pulse detection. However, in cases of extreme environmental problems or if unattributable false alarms are experienced, it may be necessary to select 2 pulse detection. To select the required pulse count set DIP switch 5 of SW3 as follows: ON OFF 1 pulse detection 2 pulse detection CONFIGURING THE PIR MOVEMENT DETECTORS Located on the PCB of the PIR Detector are two blocks of DIP switches (labelled SW2 and SW3). Note: The higher the Pulse Count the more movement will be necessary before the PIR detector will trigger the alarm. Connect the PP3 Alkaline battery to the battery clip. Note: When the 9V Alkaline battery is connected the LED behind the lens will rapidly flash for approximately 2-3 minutes until the PIR has warmed-up and stabilised. The LED will then stop flashing and turn OFF. 1 3 SW 2 SW 1. DIP switches 1 - 8 of SW2 are used to set the House Code for the PIR Detector and must be set to the same ON/OFF combination as the House Code DIP switches in the Solar Siren. DIP Switches 1-3 of SW3 must be set as follows for use with this alarm system: DIP 1 ON DIP 2 ON DIP 3 OFF 3. DIP switch 4 of SW3 is used to configure the PIR Detector for walk test mode, which allows the operation of the detector to be checked during installation without initiating an alarm. ON OFF Walk Test mode Normal operation Note: On initial installation the detector should be configured into Walk-Test mode ready for testing. SA1/SA2/SAC1 ON 2 3 4 5 6 7 8 1 Dip Switches (SW2 and SW3) PCB Position Indicator (positions 1-5) PCB Board (slides up and down to adjust position) ON 2 3 4 5 5 4 3 2 1 TESTING THE PIR MOVEMENT DETECTORS Ensure that the system is in service mode. With the PIR detector configured in Walk Test mode and mounted in position on the wall, allow 2-3 minutes for the detector to stabilise before commencing the Walk test. Walk into and move slowly around the protected area, each time the detector senses movement the LED behind the lens will flash. Note: In normal operation, with the battery cover on, the detector LED will not flash on movement detection. If necessary re-adjust the detection pattern by adjusting the mounting position of the PCB within the PIR housing. 11 3. Reconfigure the PIR Detector into Normal operation mode and refit in position. Note: When the detector is fully installed i. e. battery cover is refitted; the unit will not detect movement for approximately 45 seconds after each activation. (This feature is presant to conserve battery power and maximise the battery life). Decide which doors and windows are to be protected by fitting Magnetic Contact Detectors, (usually the front and back doors as a minimum will have Magnetic Contact Detectors fitted). However additional detectors may be fitted where required to other more vulnerable doors or windows, (e. g. [. . . ] Ensure DIP switches 9 and 10 are set correctly. If no external contacts are connected ensure jumper link fitted. Check all contacts are wired in series. Magnetic Contact Detector false alarming. 1. Ensure that gap between magnet and detector is less than 10mm. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RESPONSE ALARMS SAC1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual RESPONSE ALARMS SAC1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag