User manual RHEEM PRESTIGE 90 PLUS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual RHEEM PRESTIGE 90 PLUS. We hope that this RHEEM PRESTIGE 90 PLUS user guide will be useful to you.

Lastmanuals help download the user guide RHEEM PRESTIGE 90 PLUS.


Mode d'emploi RHEEM PRESTIGE 90 PLUS
Download
Manual abstract: user guide RHEEM PRESTIGE 90 PLUS

Detailed instructions for use are in the User's Guide.

[. . . ] or Above) Features Modulating Furnace Thermostat RHC-TST401MDMS The BEST BUY SEAL is a registered trademark of Consumers Digest Communications LLC, used under license. Heat exchanger is constructed of all stainless steel for maximum corrosion resistance and thermal fatigue reliability. s Modulating Function: when used with a modulating thermostat, modulation rate between 40% and 100% of total capacity. s Two-stage Function: when used with a two-stage thermostat, furnace operates at 40% on first stage, and stages up to 65%, then 100% for second stage. [. . . ] See "Accessories") OPTIONAL EQUIPMENT Side and bottom filter racks; return air cabinet for all sizes. NOTE: Furnace is not listed for use with fuels other than natural or L. P. All models can be converted by a qualified distributor or local service dealer to use L. P. Factory approved kits must be used to convert from natural to L. P. (propane) gas and may be ordered as optional accessories from a parts distributor. (propane) operation, refer to Conversion Kit Index Form. Fossil Fuel Kits for use with Heat Pumps. 2 Rheem Manufacturing Company THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES WARNING BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. PHYSICAL DATA AND SPECIFICATIONS--UPFLOW MODELS U. S. and Canadian Models MODEL NUMBERS INPUT­MAXIMUM (BTU/HR) [kW] HEATING CAPACITY­MAXIMUM [kW] INPUT­MINIMUM (BTU/HR) [kW] HEATING CAPACITY­MINIMUM [kW] HEATING EXT. STATIC PRESSURE [kPa] BLOWER (D X W IN. ) [mm] ECM MOTOR HP [W] UNIT AMPS MAXIMUM OVERCURRENT PROTECTION HEATING CFM­MAXIMUM [L/s] HEATING CFM­MINIMUM [L/s] COOLING CFM­RANGE [L/s] MAXIMUM EXT. STATIC PRESSURE [kPa] TEMPERATURE RISE RANGE °F [°C] MAX OUTLET AIR TEMPERATURE °F [°C] RETURN AIR CABINETS­RXGRFILTER SIZE (IN. ) [mm] BOTTOM FILTER SIZE (IN. ) [mm] SIDE APPROX. SHIPPING WEIGHT (LBS. ) [kg] AFUE RGFD-06EMCK 60, 000 [17. 58] 55, 800 [16. 35] 24, 000 [7. 03] 22, 560 [6. 61] 0. 12 [. 029] 11 x 7 [279 x 178] 1/2 [373] 8. 7 15 795 [375] 320 [151] 600-1200 [283-566] 0. 80 [0. 20] 40-70 [22. 2-38. 9] 170 [76. 7] C17B 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 127 [57. 6] 93. 4% RGFD-07EMCK 75, 000 [21. 98] 72, 000 [21. 10] 30, 000 [8. 79] 28, 200 [8. 26] 0. 12 [. 029] 11 x 7 [279 x 178] 1/2 [373] 8. 7 15 995 [470] 430 [203] 600-1200 [283-566] 0. 80 [0. 20] 40-70 [22. 2-38. 9] 180 [82. 2] C17B 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 133 [60. 3] 92. 8% RGFD-09EZCM 90, 000 [26. 38] 86, 000 [25. 20] 36, 000 [10. 55] 33, 840 [9. 92] 0. 15 [. 037] 12 x 11 [305 x 279] 1 [746] 12. 0 15 1195 [564] 515 [243] 1200-2000 [566-944] 0. 80 [0. 20] 40-70 [22. 2-38. 9] 180 [82. 2] C21B 191/4 x 25 [489 x 635] 153/4 x 25 [400 x 635] 158 [71. 7] 94. 1% RGFD-10EZCM 105, 000 [30. 77] 100, 000 [29. 31] 42, 000 [12. 31] 39, 000 [11. 57] 0. 20 [. 049] 12 x 11 [305 x 279] 1 [746] 12. 0 15 1395 [658] 600 [283] 1200-2000 [566-944] 0. 80 [0. 20] 40-70 [22. 2-38. 9] 180 [82. 2] C21B 191/4 x 25 [489 x 635] 153/4 x 25 [400 x 635] 162 [73. 5] 92. 4% RGFD-12ERCM 120, 000 [35. 17] 115, 000 [33. 70] 48, 000 [14. 07] 45, 120 [13. 22] 0. 20 [. 049] 11 x 10 [279 x 254] 1 [746] 12. 0 15 1595 [753] 685 [323] 1200-2000 [566-944] 0. 80 [0. 20] 40-70 [22. 2-38. 9] 180 [82. 2] C24B 223/4 x 25 [578 x 635] 153/4 x 25 [400 x 635] 170 [77. 1] 93. 2% MODEL IDENTIFICATION R Rheem G Gas Furnace F D -- 07E Heating Input Designation M C K S Modulating Design Series Prestige Series ® 90 Plus Gas Furnace Blower Size Variations Heat/Cool Fuel Code M = 11 x 7 C = Single/ Designation S = U. S. and [279 x 178 mm] Multi Zone K = 600-1200 CFM Canadian Electric R = 11 x 10 [283-566 L/s] Natural Gas Electric Ignition-- Input [279 x 254 mm] M = 1200-2000 CFM Ignition Nox Models BTU/HR Z = 12 x 11 [566-944 L/s] 06N 06E 60, 000 [17. 6 kW] [305 x 279 mm] 07N 07E 75, 000 [20. 5 kW] 09N 09E 90, 000 [26. 4 kW] 10N 10E 105, 000 [30. 7 kW] -- 12E 120, 000 [35. 2 kW] [ ] Designates Metric Conversions Rheem Manufacturing Company 3 UPFLOW MODELS MODEL RGFD06 07 09 10 12 A [445] 171/2 [445] 21 [533] 21 [533] 241/2 [622] 171/2 B 163/8 [416] 163/8 [416] 197/8 [505] 197/8 [505] 233/8 [594] C [397] 155/8 [397] 191/8 [487] 191/8 [487] 225/8 [575] 155/8 D 2 [51] 2 [51] 2 [51] 2 [51] 2 [51] E 15 [422] 15 [422] 181/2 [511] 181/2 [511] 22 [600] F [351] 1313/16 [351] 175/16 [440] 175/16 [440] 2013/16 [529] 1313/16 LEFT SIDE 0 0 0 0 0 MINIMUM CLEARANCE (IN. ) [mm] RIGHT SIDE 0 0 0 0 0 BACK 0 0 0 0 0 TOP 1 [25] 1 [25] 1 [25] 1 [25] 1 [25] FRONT 2 [51] 2 [51] 2 [51] 2 [51] 2 [51] VENT 0 0 0 0 0 [ ] Designates Metric Conversions 4 Rheem Manufacturing Company BLOWER PERFORMANCE DATA--RGFD MODELS MODEL RGFDBLOWER SIZE (D x W) IN. [W] 1/2 [373] BLOWER SPEED HIGH MED-HI MED LOW HIGH MED-HI MED LOW HIGH MED-HI MED LOW HIGH MED-HI MED LOW HIGH MED-HI MED LOW CFM [L/s] AIR DELIVERY EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kPa] 0. 1 [. 02]-0. 8 [. 20] 1200 [566] 1000 [472] 800 [378] 600 [283] 1200 [566] 1000 [472] 800 [378] 600 [283] 2000 [944] 1600 [755] 1400 [661] 1200 [566] 2000 [944] 1600 [755] 1400 [661] 1200 [566] 2000 [944] 1600 [755] 1400 [661] 1200 [566] 06 07 11 x 7 [279 x 178] 1/2 [373] 09 12 x 11 [305 x 279] 1 [746] 10 12 x 11 [305 x 279] 1 [746] 12 11 x 10 [279 x 254] 1 [746] [ ] Designates Metric Conversions GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. Primary and Secondary Heat Exchanger . . . . . . Limited Lifetime Rheem will provide a replacement RGFD Gas Furnace to the original purchaser if the Heat Exchanger fails AND if the following additional conditions are satisfied: a) Unit is still owned by the original purchaser; in the original installation location; AND b) Warranty is registered with Rheem Manufacturing Company, Air Conditioning Division within 60 Days of original installation or closing of your home. Product registration is available online at www. RheemAC. com/ register or by filling out the Warranty Registration card and returning it to the address listed on the reverse side of the card. All Other Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Five (5) Years *For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy. Rheem Manufacturing Company 5 ACCESSORIES--UPFLOW VENT TERMINATION KITS CONCENTRIC: Vertical/Horizontal = RXGY-E03 HORIZONTAL TWO PIPE: RXGY-D02, RXGY-D03, RXGY-D04, RXGY-G02 CONDENSATE PUMP KIT: RXGY-B01 NEUTRALIZER KIT: RXGY-A01 RETURN AIR PLENUM: RXGR-C17B RXGR-C21B RXGR-C24B EXTERNAL BOTTOM FILTER RACK: RXGF-CB EXTERNAL SIDE FILTER RACK: RXGF-CA MODEL RGFD06 07 09 10 12 FILTER RACK FILTER SIZES* INCHES [mm] RXGF-CB RXGF-CA (BOTTOM) (SIDE) 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 191/4 x 25 [489 x 635] 191/4 x 25 [489 x 635] 223/4 x 25 [578 x 635] 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] THERMOSTATS RECOMMENDED MODULATING FURNACE THERMOSTAT RHC-TST401MDMS · 7 Day 5/1/1 Programmable Modulating/Two Cool Hardwired · Works in Modulating Furnace and Modulating Furnace Dual Fuel applications (requires optional external sensor) · Bright, 12 sq. inch touchscreen display · Keypad lockout option · Hardwired · Easy, menu-driven programming · Audio prompting to ensure program change confirmation · Intuitive red/blue temperature keys · Large, easy-to-see characters · Available only through professional contractors FOSSIL FUEL KIT RXPF-F02 *PROGRAMMABLE THERMOSTAT ACCESSORIES: Adapter Plate = F61-2600 Remote F1451328 and F1451378 Sensor *Available through PROSTOCK®. [ ] Designates Metric Conversions *Filter racks are shipped without filters. Filters shipped with furnace may be used or a suitable 1" [25. 4 mm] filter. PLENUM DATA FOR "A" COILS Plenum adapters are required in some instances for use on upflow applications when plenum and furnace size do not match. FURNACE WIDTH IN. [. . . ] (including all option ­ 278 models), the burner orifice size needs to be recalculated and verified at elevations above 2000 ft. A burner orifice change may still be required. See Installation Instructions for more information. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RHEEM PRESTIGE 90 PLUS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual RHEEM PRESTIGE 90 PLUS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag