If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ROBLIN ESPACE VERRE CENTRALE. We hope that this ROBLIN ESPACE VERRE CENTRALE user guide will be useful to you.

Lastmanuals help download the user guide ROBLIN ESPACE VERRE CENTRALE.


Mode d'emploi ROBLIN ESPACE VERRE CENTRALE
Download
Manual abstract: user guide ROBLIN ESPACE VERRE CENTRALEDIMENSIONS

Detailed instructions for use are in the User's Guide.

[. . . ] This cooker hood is fitted with a 3-core mains cable with a standard 10/16A earthed plug. Alternatively the hood can be connected to the mains supply via a double-pole switch having 3mm minimum contact gap on each pole. Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the cooker hood. To ensure the safe operation of this cooker hood, we recommend that the hood should not be fitted below 65cm (for electric) or (70cm for gas) the measurements taken from the surface of the cooking appliance to the underside of the cooker hood. [. . . ] This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. The ducting used must be 150 mm (6 INS), rigid circular pipe and must be manufactured from fire retardant material, produced to BS. Wherever possible utilise rigid circular pipe which has a smooth interior, rather than the expanding concertina type ducting. The above assumes our 150 mm (6 INS) ducting is being installed. Please note ducting components and ducting kits are optional accessories and have to be ordered, they are not automatically supplied with the chimney hood. Fit the non-return backflow flaps C over the round outlet item 6 on top of the canopy while pressing Down until they snap into position, and then connect the ducting 150mm (6 INS) and secure the connections with appropriate clamping rings or adhesive tape (Fig. Before fitting the chimney to the canopy make the electrical connection as described in the section titled ELECTRICAL. Each chimney stack consists of two sections. 2a - item 7) first by expanding the chimneys slightly around the bracket and secure the chimney stacks to the brackets using the M4 screws provided. Pull on the lower chimney item 5 and secure it temporarily unscrewing a little bit the lower self tapping screws as illustrated in Fig 9. Fit the recirculation spigot R onto the chimney bracket using the same fixing screws. Your cooker hood is supplied with a deactivated pre-set stop of the boost speed. To use the cooker hood with a pre-set stop of the boost speed re-programme the hood as follows: The lights and the fan motor should be switched `OFF' to set the timer. Push the LED button `-' until the LED lights will flash : One flash of the LED lights 2, 3, and 4 = function is switched `OFF'. Two flashes of the LED lights 2, 3, and 4 = function is switched `ON'. While the 5 minutes timer is running, It is available to stop immediately the boost speed by pressing the led button 5. While the 5 minutes timer is running, the indication of saturation of the filters is switched `OFF'. If a pre-set stop for the hood is switched `ON' and the 5 minutes timer is still running, the boost speed will be switched `OFF' together with the pre-set stop for the hood after the count down of 5, 10 or 15 minutes. It is available to stop the boost speed before the count down of the preset stop of the hood by pressing the led button 5. Pre-set stop for the hood : This function allows you to program the cooker hood to automatically stop cooking after a pre-set period. The lights and the fan motor should be switched `OFF' to set the timer. Indication of saturation of the metal grease filters : After 200 hours use, one quick flash of the LED 1 will indicate that you must clean the metal grease filters. [. . . ] 4 - Release the button 0/1 MOTOR (the Leds flash for about 3 seconds : capacity's confirmation SETUP PROCESS). 5 - While the LED is flashing select the motor type used while pushing one of the 5 buttons in accordance with the following: BUTTON 0/1 Light : Motor EBM PRO 220-240 V AC 50 Hz / 220 V AC 60 Hz. : If you have not selected a motor type while the LED is flashing the microprocessor will automatically select the default motor EBM PRO 220 - 240 V AC 50 Hz / 220 V AC 60 Hz. To obtain the best performance it is advisable to switch `ON' the cooker hood a few minutes (in the boost setting) before you start cooking and you should leave it running for approximately 15 minutes after finishing. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROBLIN ESPACE VERRE CENTRALE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ROBLIN ESPACE VERRE CENTRALE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag