User manual ROBLIN IKOS/2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ROBLIN IKOS/2. We hope that this ROBLIN IKOS/2 user guide will be useful to you.

Lastmanuals help download the user guide ROBLIN IKOS/2.


Mode d'emploi ROBLIN IKOS/2
Download
Manual abstract: user guide ROBLIN IKOS/2

Detailed instructions for use are in the User's Guide.

[. . . ] € It is a possible fire risk if the hood is not sited as recommended. € To ensure the best results, the cooking fumes should be able to rise naturally towards the inlet grilles on the underside of the cooker hood and the cooker hood should be positioned away from doors and windows, which will create turbulence. € Ducting • If the room where the hood is to be used contains a fuel-burning appliance such as a central heating boiler then its flue must be of the room sealed or balanced flue type. € If other types of flue or appliances are fitted ensure that there is an adequate supply of fresh air to the room. [. . . ] As this is a complex operation, it should only be undertaken by the technician installing the kitchen units or by a competent person who knows the final dimensions of the units. 4) Fixing the canopy: Before starting to fix the canopy it will be necessary to adjust the support brackets by turning the adjustment screws Vr in a clockwise direction until their reach their limit (Fig. Level the hood by turning the adjustment screws and then locking the screws 1. 5) Ducting: The hood is more effective when used in the extraction mode (ducted to the outside). When the cooker hood is ducted to the outside, charcoal filters are not required. The ducting used must be 150 mm (6 INS), rigid circular pipe and must be manufactured from fire retardant material, produced to BS. Wherever possible use rigid circular pipe which has a smooth interior, rather than the expanding concertina type ducting. The above assumes our 150 mm (6 INS) ducting is being installed. Please note ducting components and ducting kits are optional accessories and have to be ordered, they are not automatically supplied with the chimney hood. Connect the ducting 150mm (6 INS) over the round outlet item 6 on top of the canopy and secure the connections with appropriate clamping rings or adhesive tape (Fig. Remove the grease filters (see paragraph Maintenance) being sure that the connector of the mains cable is correctly inserted in the socket placed on the side of the fan. Before fitting the chimney to the canopy make the electrical connection as described in the section titled ELECTRICAL. When the electrical connection has been made, test the lights and the fan motor. Upper chimney stack •Slightly widen the two sides of the upper chimney stack (Fig. 5 - Item 7a) and hook them behind the brackets item 2 making sure that they are well seated. €Secure the sides to the brackets using the 4 screws 12c (2, 9 x 9, 5) supplied. Lower chimney stack •Slightly widen the two sides of the chimney stack (Fig. 5 - Item 7b) and hook them between the upper chimey stack and the wall, making sure that they are well seated. €Fix the lower part laterally to the hood body using the 2 screws 12c (2, 9 x 9, 5) supplied. Fit the recirculation spigot bracket item 4 onto the upper chimney wall bracket using the same fixing screws (Fig. Put the spigot item R into the spigot bracket item 4• Insert the connection extension pieces laterally item G in the spigot. Make sure that the outlet of the extension pieces item G is horizontally and vertically aligned with the chimney outlets. [. . . ] 27 250 W 200-240 V 50 Hz 220 V - 60 Hz A - AZUR - AZUR - AZUR BLAU BK - BLACK - NOIR- SCHWARZ B - BLUE - BLEU - BLAU Br - BROWN - BRUN - BRAUN G-Y - GREEN YELLOW - VERT JAUNE - GRÜN GELB Gr - GREY - GRIS - GRAU L B - LIGHT BLUE - BLEU CLAIR - HELL BLAU P - PINK - ROSE - ROSA V - PURPLE - MAUVE - MALVER FARBIG R - RED - ROUGE - ROT W - WHITE - BLANC - WEISS W-P - WHITE PINK - BLANC ROSE - WEISS ROSA Y - YELLOW - JAUNE - GELB M 2 x 20 W - 12 V depuis :Janvier 2011 (From) 3S_Ikos_2_M_90_V2011-01 IKOS/2 MAJ (UPDATE) :11/01/11 Page 1/1 UK ELECTRICAL CONNECTION ELECTRICAL REQUIREMENTS Any permanent electrical installation must comply with the latest I. For your own safety this should be undertaken by a qualified electrician e. Your local Electricity Board, or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting (NICEIC). ELECTRICAL CONNECTION Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the cooker hood. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROBLIN IKOS/2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ROBLIN IKOS/2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag