User manual ROBLIN LIDO DESIGN MURALE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ROBLIN LIDO DESIGN MURALE. We hope that this ROBLIN LIDO DESIGN MURALE user guide will be useful to you.

Lastmanuals help download the user guide ROBLIN LIDO DESIGN MURALE.


Mode d'emploi ROBLIN LIDO DESIGN MURALE
Download
Manual abstract: user guide ROBLIN LIDO DESIGN MURALE

Detailed instructions for use are in the User's Guide.

[. . . ] If the room where the hood is to be used contains a fuel-burning appliance such as a central heating boiler then its flue must be of the room sealed or balanced flue type. â· If other types of flue or appliances are fitted ensure that there is an adequate supply of fresh air to the room. Ensure the kitchen is fitted with an airbrick, which should have a cross-sectional measurement equivalent to the diameter of the ducting being fitted, if not larger. â· The ducting system for this cooker hood must not be connected to any existing ventilation system, which is being used for any other purposes or to a mechanically controlled ventilation ducting. [. . . ] Wherever possible use rigid circular pipe which has a smooth interior, rather than the expanding concertina type ducting. The above assumes our 150 mm (6 INS) ducting is being installed. Please note ducting components and ducting kits are optional accessories and have to be ordered, they are not automatically supplied with the chimney hood. Place the anti-backflow flats item 8 over the round outlet item 6 and connect the ducting 150mm (6 INS) over the round outlet on top of the canopy and secure the connections with appropriate clamping rings or adhesive tape (Fig. Before fitting the chimney to the canopy make the electrical connection as described in the section titled ELECTRICAL. When the electrical connection has been made, test the lights and the fan motor. Each chimney stack consists of two sections. 1 - item 7a & b) first byexpanding the chimneys slightly to allow them to clamp around the bracket item 2 and secure the Chimney stacks to the brackets using the two M4 screws item 12c provided. Fit the lower chimney sections by expanding the chimneys slightly to allow them from the top of the canopy to clamp around the upper chimney sections. Fit the recirculation spigot R onto the upper chimney wall bracket using the same fixing screws (Fig. Connect the ducting 150mm (6 INS) not provided between motors item 6 and the recirculation spigot and secure the connections with appropriate clamping rings or adhesive tape. Before fitting the chimney to the canopy make the electrical connection as described in the section titled ELECTRICAL. When the electrical connection has been made, test the lights and the fan motor. Insert the charcoal filter into the base of the motor housing and secure the filter with two metal securing straps item A as illustrated in Fig. Each chimney stack consists of two sections. 1 - item 7a & b) first by expand-ing the chimneys slightly to allow them to clamp around the bracket item 2 and secure the chimney stacks to the brackets using the two M4 screws item 12c provided. Fit the lower chimney sections by expanding the chimneys slightly to allow them from the top of the canopy to clamp around the upper chimney sections. Function Display Turns the suction motor on and off at the last Displays the speed set speed used. Activates intensive speed from any other speed even with the motor off. This speed is timed to run for 10 minutes, after which the system returns to the previous speed. suitable to deal with maximum cooking fumes. Activates the motor at a speed that allows extraction of 100 m3/h for 10 minutes every hour, after which the motor stops. [. . . ] Repairs carried out by other persons will invalidate the guarantee. â· Use only genuine spare parts. Should these warnings fail to be observed it could affect the safety of your cooker hood. â· When ordering spare parts quote the model number and serial number written on the rating plate, which is found on the casing behind the grease filters inside the hood. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROBLIN LIDO DESIGN MURALE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ROBLIN LIDO DESIGN MURALE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag