User manual ROBLIN LINEAR 1500 MURALE DIMENSIONS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ROBLIN LINEAR 1500 MURALE. We hope that this ROBLIN LINEAR 1500 MURALE user guide will be useful to you.

Lastmanuals help download the user guide ROBLIN LINEAR 1500 MURALE.


Mode d'emploi ROBLIN LINEAR 1500 MURALE
Download
Manual abstract: user guide ROBLIN LINEAR 1500 MURALEDIMENSIONS

Detailed instructions for use are in the User's Guide.

[. . . ] This cooker hood is fitted with a 3-core mains cable with a standard 10/16A earthed plug. Alternatively the hood can be connected to the mains supply via a double-pole switch having 3mm minimum contact gap on each pole. Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the cooker hood. To ensure the safe operation of this cooker hood, we recommend that the hood should not be fitted below 65cm (for electric) or (70cm for gas) the measurements taken from the surface of the cooking appliance to the underside of the cooker hood. [. . . ] 650 mm when fitting above an electric hotplate and 700 mm when fitting above a gas hotplate. select the height required using the measurements illustrated in Fig. 9 and fix the two metal diffusers to the frame of the chimney brackets using the twice height 5 x 10T hexagonal headed screws. A spot of coloured paint on the diffusers defines the positioning for the controls. DUCTING The hood is more effective when used in the extraction mode ( ducted to the outside). When the cooker hood is ducted to the outside, charcoal filters are not required. The ducting used must be 150 mm (6 ins), rigid circular pipe and must be manufactured from fire retardant material, produced to BS. Wherever possible utilise rigid circular pipe which has a smooth interior, rather than the expanding concertina type ducting. The above assumes our 150 mm (6 ins) ducting is being installed. Please note ducting components and ducting kits are optional accessories and have to be ordered, they are not automatically supplied with the chimney hood. Fit the noise-reduction tubes over the round outlets on top of the canopy while pressing down until they snap into position and then fit the non-return backflow flaps onto the top of the noise-reduction tubes as illustrated Fig. You should keep applying pressure to the `+' and `-` button until the required speed is selected. It is advisable too that you should leave it running in the boost setting for approximately 5 minutes after finishing. Pre-set stop of the boost speed : A pre-set stop after 5 minutes of the boost speed is available. Your cooker hood is supplied with a deactivated pre-set stop of the boost speed. With a pre-set stop of the boost speed re-programme the hood as follows: The lights and the fan motor should be switched `OFF' to set the timer. Push the LED button `-' until the LED lights will flash : One flash of the LED lights 2, 3, and 4 = function is switched `OFF'. Two flashes of the LED lights 2, 3, and 4 = function is switched `ON'. While the 5 minutes timer is running, It is available to stop immediately the boost speed by pressing the led button 5. While the 5 minutes timer is running, the indication of saturation of the filters is switched `OFF'. If a pre-set stop for the hood is switched `ON' and the 5 minutes timer is still running, the boost speed will be switched `OFF' together with the pre-set stop for the hood after the count down of 5, 10 or 15 minutes. It is available to stop the boost speed before the count down of the preset stop of the hood by pressing the led button 5. [. . . ] 3 - Reconnect the mains supply while pushing the button 0/1 MOTOR for at least 2 seconds. 4 - Release the button 0/1 MOTOR (the Leds flash for about 3 seconds : capacity's confirmation SETUP PROCESS). 5 - While the LED is flashing select the motor type used while pushing one of the 5 buttons in accordance with the following: BUTTON 0/1 Light : Motor EBM PRO 220-240 V AC 50 Hz / 220 V AC 60 Hz. : If you have not selected a motor type while the LED is flashing the microprocessor will automatically select the default motor EBM PRO 220 - 240 V AC 50 Hz / 220 V AC 60 Hz. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROBLIN LINEAR 1500 MURALE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ROBLIN LINEAR 1500 MURALE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag