User manual ROBLIN MILANO 750M-5047000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ROBLIN MILANO 750M-5047000. We hope that this ROBLIN MILANO 750M-5047000 user guide will be useful to you.

Lastmanuals help download the user guide ROBLIN MILANO 750M-5047000.


Mode d'emploi ROBLIN MILANO 750M-5047000
Download
Manual abstract: user guide ROBLIN MILANO 750M-5047000

Detailed instructions for use are in the User's Guide.

[. . . ] Gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air. When the cooker hood is used in conjunction with appliances supplied with energy other than electric, the negative pressure in the room must not exceed 0, 04 mbar to prevent fumes being drawn back into the room by the cooker hood. € If the supply cord is damaged, it must be replaced from the manufacturer or its service agent. [. . . ] 11a Vr (B) (A) 11 Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120 mm, the choice of which is left to the installer. € To install a ø 120 mm air exhaust connection, insert the reducer flange 9 on the hood body outlet. € Fix the pipe in position using sufficient pipe clamps (not supplied). • Remove possible charcoal filters. ø 150 9 ø 120 EN 1 17 RECYCLING VERSION AIR OUTLET To install the hood in recycling version, the optional charcoal filter kit must be purchased. 16 8 12d 12c • Remove the chimney angle bracket. € Screw the filter cover onto the air outlet, using four screws 12c (2. € Fix the air outlet grid 8 on the recirculation air outlet using the 2 screws 12d (2, 9 x 9, 5) provided. ELECTRICAL CONNECTION • Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm. € Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan. Flue assembly The chimney can only be installed with exhausting hood • Fasten the angle iron 15 to the hood canopy using the screws 12d (2, 9 x 9, 5) provided. Upper exhaust flue • Slightly widen the two sides of the upper flue and hook them behind the brackets 7. 1, making sure that they are well seated. € Secure the sides to the brackets using the 4 screws 12c (2, 9 x 6, 5) supplied. Lower exhaust flue • Slightly widen the two sides of the flue and hook them between the upper flue and the wall, making sure that they are well seated. € Fix the lower part laterally to the hood body using the 2 screws 12c (2, 9 x 6, 5) supplied. 1 12c 15 12c 1 EN 1 18 USE Control panel Button A B C D Function Turns the suction motor on and off at the last speed set Decreases the working speed. Activate Intensive speed from any other speed, including motor off. This speed is set to operate for 10 minutes, after which the system returns to the speed that was set before. suitable to deal with maximum levels of cooking fumes. Cannot be activated if Delay or 24H are active. 24H function Starts the Motor at recirculation speed for 10 minutes every hour, for 24h, after which the Motor stops. [. . . ] (If the surface of the filter changes colour as time goes by, this will have absolutely no effect on the efficiency of the filter itself. ) • Replace, taking care to ensure that the handle faces forwards. EN 2 21 Activated Charcoal Filter (Recirculation Version) It cannot be washed or regenerated, and must be changed when the EF symbol on the display appears, or at least once every 4 months. The Alarm signal, if it has been activated, only appears when the Suction motor is turned off. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROBLIN MILANO 750M-5047000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ROBLIN MILANO 750M-5047000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag