User manual ROBLIN VIZIO/3

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ROBLIN VIZIO/3. We hope that this ROBLIN VIZIO/3 user guide will be useful to you.

Lastmanuals help download the user guide ROBLIN VIZIO/3.


Mode d'emploi ROBLIN VIZIO/3
Download
Manual abstract: user guide ROBLIN VIZIO/3

Detailed instructions for use are in the User's Guide.

[. . . ] € It is a possible fire risk if the hood is not sited as recommended. € To ensure the best results, the cooking fumes should be able to rise naturally towards the inlet grilles on the underside of the cooker hood and the cooker hood should be positioned away from doors and windows, which will create turbulence. € Ducting • If the room where the hood is to be used contains a fuel-burning appliance such as a central heating boiler then its flue must be of the room sealed or balanced flue type. € If other types of flue or appliances are fitted ensure that there is an adequate supply of fresh air to the room. [. . . ] € DUCTING The hood is more effective when used in the extraction mode (ducted to the outside). When the cooker hood is ducted to the outside, charcoal filters are not required. The ducting used must be 150 mm (6 INS), rigid circular pipe and must be manufactured from fire retardant material, produced to BS. Wherever possible utilise rigid circular pipe which has a smooth interior, rather than the expanding concertina type ducting. The above assumes our 150 mm (6 INS) ducting is being installed. Please note ducting components and ducting kits are optional accessories and have to be ordered, they are not automatically supplied with the chimney hood. Fit the non-return backflow flaps C over the round outlet item 6 on top of the canopy while pressing down until they snap into position, and then connect the ducting 150mm (6 INS) and secure the connections with appropriate clamping rings or adhesive tape (Fig. Before fitting the chimney to the canopy make the electrical connection as described in the section titled ELECTRICAL. Each top and lower chimney stack consists of two sections. Place the top chimney with the slops facing downwards (Fig. 6c - item 7a) when installing the ducting version and secure the chimney stacks to the brackets using the M4 screws provided. Fit the recirculation spigot R onto the chimney bracket using the same fixing screws Fig. Connect the ducting 150mm (6 INS) not provided between motors item 6 and the recirculation spigot and secure the connections with appropriate clamping rings or adhesive tape (Fig. Make the electrical connection as described in the section titled ELECTRICAL. Each top and lower chimney stack consists of two sections. Place the top chimney with the slops facing upwards (Fig. 6c - item 7a) when installing the recirculation version and secure the chimney stacks to the brackets using the M4 screws provided. 9) Check the connectors of the motor as illustrated in Fig. Insert the charcoal filter into the base of the motor housing and secure the filter with two securing straps A as illustrated Fig. 8 GB 4 OPERATION A B C D Control panel E F G H Button A B C D Function Display Turns the suction motor on and off at the last Displays the speed set speed used. Activates intensive speed from any other speed even with the motor off. This speed is timed to run for 10 minutes, after which the system returns to the previous speed. [. . . ] If lamp failure has occurred then it should be replaced with identical replacement. Do not replace with any other type of lamp and do not fit a lamp with a higher rating. 7 GUARANTEE AND AFTER SALES SERVICE • In the event of any malfunction or anomaly, notify your fitter who will have to check the appli- 10 GB ance and its connection. The wires in this mains lead are coloured in accordance with the following code: Green & Yellow Earth ELECTRICAL CONNECTION Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the cooker hood. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROBLIN VIZIO/3

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ROBLIN VIZIO/3 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag