User manual ROBLIN WINDY PRO 1000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ROBLIN WINDY PRO 1000. We hope that this ROBLIN WINDY PRO 1000 user guide will be useful to you.

Lastmanuals help download the user guide ROBLIN WINDY PRO 1000.


Mode d'emploi ROBLIN WINDY PRO 1000
Download
Manual abstract: user guide ROBLIN WINDY PRO 1000

Detailed instructions for use are in the User's Guide.

[. . . ] If the room where the hood is to be used contains a fuel-burning appliance such as a central heating boiler then its flue must be of the room sealed or balanced flue type. If other types of flue or appliances are fitted ensure that there is an adequate supply of fresh air to the room. Ensure the kitchen is fitted with an airbrick, which should have a cross-sectional measurement equivalent to the diameter of the ducting being fitted, if not larger. The ducting system for this cooker hood must not be connected to any existing ventilation system, which is being used for any other purposes or to a mechanically controlled ventilation ducting. [. . . ] Fit the silent pack item 5 as illustrated in fig. 6, operation 1 and 2 by clamping the two plastic rings on either side of the motor diffuser and fitting together noise-reduction casings and plastic rings. Connect the ducting 200 mm ( 8ins) onto the round outlets on the top of the canopy and onto the round inlet of the motors at a distance and secure the connections with appropriate clamping rings or adhesive tape. Connect the earth connection onto the terminal marked with the earth symbol and clamp the connector onto the motor housing as illustrated Fig. Fit the upper section item S first by expanding the chimney or coloured green or green and yellow. The wire which is coloured blue must be connected to the terminal which is marked with the letter N Slightly to allow it to clamp around the brackets item 2. Secure the chimney stack to the brackets using the four self tapping screws provided. Fit the lower chimney section item I by expanding the chimney slightly to allow it to clamp around the upper chimney section item S, and the bracket on top of the canopy item C as illustrated in fig. Secure the chimney stack to the bracket using the two self tapping screws provided. 1) Fit the recirculation spigot item R over the round outlet on top of the canopy while pressing down on the spigot until it snaps into position as illustrated in fig. Note : The two recirculation ducts item G must be fitted onto the recirculation spigot R before fitting onto the canopy item C 2) Remove the metal grease filters and place one charcoal filter at a time over the grilles on either side of the motor housing and turn clockwise into position ( A ) as illsutrated in fig. 3) Fit together noise-reduction casings and charcoal filters without the plastic rings on either side of the motor housing as illustrated in fig. To use the cooker hood in the recirculation mode re-programme the hood as follows: Starting in the recirculation mode Press the `+' button for 10 seconds (while the motor and lights are switched `OFF') and the two LED lights will flash twice to indicate confirmation that the cooker hood is in the recycling mode. Reverting to the extraction mode Press the `+' button for 10 seconds (while the motor and lights are switched `OFF') and the two LED lights will flash once to indicate confirmation that the cooker hood is in the extraction mode. The fan speed will be increased if constant pressure is kept on the (+) button. To obtain the best performance it is advisable to switch `ON' the cooker hood a few minutes (in the boost setting) before you start cooking and you should leave it running for approximately 10 minutes after finishing. press LED button 5 to switch `OFF' the fan motor immediately. Indication of saturation of the metal grease filters After 100 hours use, one quick flash of the LED F will indicate that you must clean the metal grease filters. This indication is not available when the fan motor is switched OFF. Indication of saturation of the active charcoal filter After 200 hours use, two quick flash of the LEDS F & C will indicate that you must replace the active charcoal filter and clean the metal grease filters. Two flashes of the LED lights F and C = function is switched `ON'. To reset the 100 hours timer back to zero requires the motor and lights must be switched `OFF'; then and proceed as follows: Press the LED button `+' for 3 to 4 seconds and the LED lights F and C will flash to confirm the programme has been reset to zero. [. . . ] Any permanent electrical installation must comply with the latest I. For your own safety this should be undertaken by a qualified electrician e. Your local Electricity Board, or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting (NICEIC). Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the cooker hood. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROBLIN WINDY PRO 1000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ROBLIN WINDY PRO 1000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag