User manual ROCKTRON REPLIFEX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ROCKTRON REPLIFEX. We hope that this ROCKTRON REPLIFEX user guide will be useful to you.

Lastmanuals help download the user guide ROCKTRON REPLIFEX.


Mode d'emploi ROCKTRON REPLIFEX
Download
Manual abstract: user guide ROCKTRON REPLIFEX

Detailed instructions for use are in the User's Guide.

[. . . ] G U I T A REPLIFEX R E F F E C T S P R O C TM E S S O R User's Manual HUSH ® licensed by ® May be covered by one or more of the following: U. S. Patents #4538297, 4647876, 4696044, 4745309, 4881047, 4893099, 5124657, 5263091, 5268527, 5319713 and 5333201. Foreign patents pending. PRECAUTIONS NOTE: IT IS VERY IMPORTANT THAT YOU READ THIS SECTION TO PROVIDE YEARS OF TROUBLE FREE USE. All warnings on this equipment and in the operating instructions should be adhered to and all operating instructions should be followed. [. . . ] The SHAPE parameter determines the waveshape of the tremolo signal. Selecting a different waveshape produces a different tremolo effect. The TIME parameter determines the multiplier by which a new modulation rate will be selected for the RATE parameter when the Tap Delay feature of the ReplifexTM is used. (See Section 7: "Tap Delay" for more information on the Tap Delay feature. ) LOCATION TREM DPTH TREM RATE SHAPE TIME 23 Functions and Parameter Descriptions PHASER Function Phase shifting involves splitting the input signal into two signals, then shifting the phase of different frequencies of one signal before mixing it back with the original signal. The PARAMETER SELECT control will allow you to access each of the following Phaser parameters: PHASER I/O The PHASER I/O parameter determines whether the phase shift circuit is active or bypassed for the current preset. The PHASER PAN parameter allows you to pan the phase shifted signal to the left or right channel by any amount. The PHASER DEPTH parameter determines the modulation depth of the phase shift effect. Higher parameter settings result in the sweep of the filtering effect occurring over a wider frequency range. The RATE parameter determines the speed at which the phase shifted signal is modulated. The PHASER RESONANCE parameter adds feedback to the Phaser so that it has a more pronounced effect. The PHASER STAGES parameter determines how many stages of phase shift are to be active. A parameter setting of "4" produces a result similar to a vintage Phase 90, while a setting of "6" emulates other common phaser pedals. The TIME parameter determines the multiplier by which a new modulation rate will be selected for the RATE parameter when the Tap Delay feature of the ReplifexTM is used. (See Section 7: "Tap Delay" for more information on the Tap Delay feature. ) The PHASER LEVEL parameter allows you to control the level of the phaser signal at the output of the ReplifexTM relative to the direct signal and other effect signals. PSR PAN PSR DEPTH RATE P>RESONANCE PSR STAGES TIME PHASER LVL 24 Functions and Parameter Descriptions FLANGER Function Flanging splits the input signal into two individual delayed signals (Voice 1 and Voice 2), then modulating the delayed signals so that, when summed back with the direct signal, phase cancellations will occur at some frequencies while peaks in the response will occur at others. The PARAMETER SELECT control will allow you to access these FLANGER parameters: FLANGER I/O The FLANGER I/O parameter determines whether the flange circuit is active or bypassed for the current preset. The FLANGER OUTPUT 1 parameter determines the overall volume of Voice 1. The FLANGER PAN 1 parameter allows you to pan Voice 1 to the left or right channel. The FLANGER DEPTH 1 parameter adjusts the amount of modulation of Voice 1. Lower DEPTH settings produce more subtle effects, while higher settings will result in a more drastic effect. The FLANGER RATE 1 parameter determines the speed at which Voice 1 is modulated. The TIME1 parameter determines the multiplier by which a new modulation rate will be selected for the RATE 1 parameter when the Tap Delay feature of the ReplifexTM is used. (See Section 7: "Tap Delay" for more information on the Tap Delay feature. ) The FLANGER OUTPUT 2 parameter determines the overall volume of Voice 2. The FLANGER PAN 2 parameter allows you to pan Voice 2 to the left or right channel. The FLANGER DEPTH 2 parameter adjusts the amount of modulation of Voice 2. [. . . ] Any number of errors other than "0" means that the ReplifexTM may not have initialized properly and the process should be repeated. ERRORS 0 The ReplifexTM will remain in this condition until the FUNCTION SELECT control is turned to exit the Factory Restore function. The preset currently recalled will be the preset most recently restored into the current location. Restoring the ReplifexTM controller assignments: The controller assignments for the Replifex can also be reinitialized without affecting presets and other stored information. Reinitialization of the controller assignments is necessary when setting up the Replifex to operate in remote mode with a Rocktron All Access footswitch. To reinitialize only the controller assignments, enter a code number of "244" at Step 3 on the preceding page (instead of the "243" shown). 62 Operating the ReplifexTM Selecting a Power On Preset The Replifex allows you to store a Power On preset which will always be recalled when the unit is turned on. 1 2 Step 1 Turn the PRESET control to the preset number you wish to be recalled each time the unit is turned on. 34 PRESET TITLE Step 2 Press the STORE button while viewing the preset number and title to save it as the Power On preset. PWR ON PR STORED 63 Operating the ReplifexTM Using the Replifex with a Rocktron All Access in REMOTE mode A Rocktron All Access MIDI footswitch can be configured as a dedicated remote control for the Replifex - allowing direct access to specific Replifex features and parameters from the footswitch at any time. Step 1 To use an All AccessTM footswitch as a dedicated remote, connect the MIDI OUT of the All AccessTM to the REMOTE jack of the ReplifexTM using a 7-pin MIDI cable, as shown below. To set up the ReplifexTM for remote operation, do the following: Step 2 Reinitialize the controller assignments as shown on page 62 under the heading "Restoring the ReplifexTM Controller Assignments". [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROCKTRON REPLIFEX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ROCKTRON REPLIFEX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag