User manual SAMSUNG NS180HHXEH

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SAMSUNG NS180HHXEH. We hope that this SAMSUNG NS180HHXEH user guide will be useful to you.

Lastmanuals help download the user guide SAMSUNG NS180HHXEH.


Mode d'emploi SAMSUNG NS180HHXEH
Download
Manual abstract: user guide SAMSUNG NS180HHXEH

Detailed instructions for use are in the User's Guide.

[. . . ] Duct Type Series BIG duct : NSHH user & installation manual Air Conditioner imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www. samsung. com/register E DB98-33920A(3) Features of your new air conditioner Cool Summer Offer On those hot sweltering summer days and long restless nights, there is no better escape from the heat than the cool comforts of home. Your new air conditioner brings an end to exhausting hot summer days and lets you rest. This summer, beat the heat with your own air conditioner. Cost Efficient System Your new air conditioner not only provides maximum cooling power in the summer, but can also be an efficient heating method in the winter with the advanced "Heat pump" system. [. . . ] f The unit must be plugged into an independent circuit if applicable or connect the power cable to the auxiliary circuit breaker. An all pole disconnection from the power supply must be incorporated in the fixed wiring with a contact opening of >3mm. f The air conditioner must be installed in accordance with national wiring regulations and safety regulations wherever applicable. f The electric work must be done by service agent or similarly qualified persons according to national wiring regulations and use only rated cable. - If the capacity of the power cable is insufficient or electric work is not properly completed, electric shock or fire may occur. 14 f Install the cables with supplied cables firmly. Fix them securely so that external force is not exerted to the terminal board. - If the connection or fixing is incomplete, heat generation, electric shock or fire may occur. f Connect the power cable between the indoor and outdoor unit properly so that the electrical component box cover is not get loosen and attach the cover securely. - If the the cover is attached incompletely, heat generation, electric shock or fire of the terminal board may occur. · Make sure that you earth the cables. - Do not connect the earth wire to the gas pipe, water pipe, lighting rod or telephone wire. If earthing is not complete, electric shock or fire may occur. - If the circuit breaker is not installed, electric shock or fire may occur. · Make sure that the condensed water dripping from the drain hose runs out properly and safely. · Install the power cable and communication cable of the indoor and outdoor unit at least 1m away from the electric appliance. · Install the indoor unit away from lighting apparatus using the ballast. - If you use the wireless remote control, reception error may occur due to the ballast of the lighting apparatus. · Do not install the air conditioner in following places. - Place where there is mineral oil or arsenic acid. Resin parts flame and the accessories may drop or water may leak. The capacity of the heat exchanger may reduce or the air conditioner may be out of order. - The place where corrosive gas such as sulfurous acid gas generates from the vent pipe or air outlet. [. . . ] Using the product outside this range may cause malfunction. · Select an adequate option code within the External Static Pressure range for each indoor unit. Selecting an inadequate option code may cause malfunction. · The option code can be chosen according to the External Static Pressure ranges: 5~7. 5mmAq, 7. 5~12. 5mmAq, 12. 5~17. 5mmAq, 17. 5~22. 5mmAq, 22. 5~25. 0mmAq (Refer to the above table). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SAMSUNG NS180HHXEH

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SAMSUNG NS180HHXEH will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag