User manual SANYO MCO-20AIC BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SANYO MCO-20AIC. We hope that this SANYO MCO-20AIC user guide will be useful to you.

Lastmanuals help download the user guide SANYO MCO-20AIC.


Mode d'emploi SANYO MCO-20AIC
Download
Manual abstract: user guide SANYO MCO-20AICBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] Mistry 2007 Decontamination · Active Background Contamination ControlTM fights contamination while cell culture protocols are in process. The patented SafeCellTM UV system scrubs interior airflow to destroy airborne and humidity pan contaminants. Exclusive InCu SaFeTM copper-enriched stainless steel interior surfaces assure constant germicidal protection. Temperature and Humidity Control · The patented Direct Heat and AirTM jacket system manages setpoint temperature through multiple, variable warming points under microprocessor control. · The humidity pan is easy to fill, easy to clean; the automatic optical sensor advises of low water level. No exposure to UV Five-minute exposure to SafeCellTM UV Cabinet Design Control and Monitoring · Control and information center includes central mounted touchpad and digital display. [. . . ] · An optional automatic CO2 switchover system is available. · A two-stage regulator from the supply cylinder to the incubator is required. See Accessories. SafeCellTM UV System MCO-20AIC and 40AIC include SafeCellTM UV contamination control technology based on an integrated combination of narrow bandwidth, ozone-free ultraviolet light, ceramic infrared CO2 control, InCu SaFeTM copper-enriched stainless steel alloy interiors and Direct Heat and Air JacketTM heating managed by a microprocessor controller. These incubators offer the industry's most stable cell culture environment and are useful for the most critical applications where continuous contamination control is essential to cell viability. SANYO SafeCellTM UV Series CO2 incubators offer significant economic benefits by minimizing interruptions for decontamination, by improving cell culture growth and expression under stable, repeatable conditions, and by minimizing the potential for product loss. · SafeCellTM UV includes a programmable ultraviolet lamp, isolated from cell cultures, that sterilizes conditioned air and humidity reservoir water to prevent contamination without affecting cell cultures in vitro. · SafeCellTM UV inhibits the growth of mycoplasma, bacteria, molds, spores, yeasts and fungi without costly HEPA filter air scrubbers which accumulate contaminants in the chamber air. · All interior components, including the air management plenum, shelf supports, humidity pan and blower wheel assembly are easily removable without tools if required. · When components are removed, all interior surfaces are exposed for conventional wipe down. · Large curve corners and electropolished surfaces are easy to clean. Mycoplasma Strain Mycoplasma fermentans PG18 Mycoplasma orale CH19299 YES Mycoplasma arginini G230 Mycoplasma hominis PG21 NO YES ActiveBackground Contamination ControlTM AcontinuousActiveBackgroundContaminationControlTM process eliminates contamination without downtime. At the base of the plenum an isolated beam of high intensity, ozone-free ultraviolet light destroys contaminants in the air and in the humidity water reservoir, away from active cell cultures. · Contaminants trapped within the distilled water pan are destroyed by ultraviolet light. · Sterile, humidified air is released from the lower plenum for vertical convection through and around the 6 perforated shelves. Interior air motion is suspended when the door is opened, minimizing movement of room air contaminants into the chamber. · UV light is isolated by the plenum cover to protect cell cultures · Airborne contaminants are eliminated by an automatic UV cycle that automatically turns ON for a specified period after each door opening. · Trace contaminants that attach to interior surfaces are destroyed by the passive germicidal properties of the InCu SaFeTM surfaces. SafeCellTM UV Mode After Door Opening OFF 24 Hour Function UV lamp automatically ON for five minutes after door is closed decontaminates incoming room air. Useful for overnight decontamination prior to first use, clinical decontamination protocols between patients, or following total chamber wipe-out after maintenance or service. The SafeCellTM UV lamp cycle is factory set for normal use, and can be re-programmed as desired by entering parameters through the central microprocessor control panel. Conventional Copper C1100 InCu SaFeTM Construction for Germicidal Protection YES 7 Design & Technology Direct Heat and Air JacketTM Heating System The patented Direct Heat and Air JacketTM surrounds the inner walls with a natural convection airflow that converts to radiant wall heat through thermal conduction to achieve accurate, uniform and highly responsive temperature control within the chamber. · The microprocessor controller directs proportional distribution of power to independent heating sources surrounding the chamber. · Arranged in three zones, these sources include the side, top and rear walls, the chamber base and the outer door. · Each zone is controlled by the microprocessor which manages continuous feedback from the incubator chamber sensors. The patented Direct Heat and Air JacketTM heating system distributes proportional energy to the interior chamber through a natural convection air jacket surrounded by a high density insulation to protect against ambient temperature fluctuations CO2 Incubator Design Elevated Humidity, Low Water Level Warning To avoid cell culture desiccation, the MCO-20AIC & 40AIC CO2 incubator maintains ~95% RH at 37°C. · Humidification is achieved by a combined forced-air and natural evaporation method enhanced by the Direct Heat and Air JacketTM base heater, and protected by an optical water level indicator to warn of low water in the removable humidity pan. · The humidity removes easily for regular cleaning and refill. [. . . ] · An optional roller base is recommended for stacked installations to permit mobility if required; see Accessories. 10 11 Specifications & Accessories Accessories (SANYO Large Capacity CO2 Incubators) Single Chamber Model Number Dual Chamber Model Number MCO-20AIC MCO-40AIC Catalog Number MCO-21GC MCO-100L MCO-20RB MCO-58ST MTR-480 MCO-420MA Built-In Optional Accessories Automatic CO2 Cylinder Switchover System CO2 Cylinder Regulator, CGA fitting 320 Roller Base. For use in single or stacked installations. Connector, cable and software not supplied. Located at rear of chamber, analog 4-20mA. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SANYO MCO-20AIC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SANYO MCO-20AIC will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag