User manual SANYO MCO-5M BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SANYO MCO-5M. We hope that this SANYO MCO-5M user guide will be useful to you.

Lastmanuals help download the user guide SANYO MCO-5M.


Mode d'emploi SANYO MCO-5M
Download
Manual abstract: user guide SANYO MCO-5MBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] The patented SafeCellTM UV system scrubs interior airflow to destroy airborne and humidity pan contaminants. Exclusive InCu SaFe copper-enriched stainless steel interior surfaces assure constant germicidal protection. TM CO2 Control SANYO proprietary single-beam, dual detector infrared (IR2) CO2 sensor delivers precise CO2 control, quick recovery following door openings, and auto sampling with no moving parts. · Continuous zero calibration is standard. · An optional semi-automatic, one-point calibration system is available. [. . . ] Interior surfaces are exposed. Resolve: 90 min. Start Cycle: 30 min. Press H2O2 start button. UV lamp glows for 90 minutes, reducing H2O2 to harmless water droplets. Finish. Shelves, humidity pan and plenum are returned to operating position. SterisonicTM GxP H202 Sterilization Cycle (3 Hours, total) Elapsed Time: 15 min. 30 min. 45 min. 1 2 3 4 5 6 Conventional High Heat Decontamination (24 Hours, total) PREP: 15 min. Remove interior components sensitive to high heat. Start Cycle: 90 min. Interior chamber elevates to high heat. Sterilize: 14 hours Interior chamber remains at high heat. 4 · Digital alphanumeric LCD display. · Message display · Pop-up menu · H2O2 sterilization sequence start key · Menu call button Sterilization Cycle The H2O2 sterilization cycle is monitored for safety and cycle status. A physical interlock and neutralization sequence assures total sterilization and operator safety. 1. Start Cycle: When the H2O2 button is pressed a confirming message prompts the user to proceed with the sterilization cycle or cancel. 2. H2O2 Vapor Cycle: Once the door locks automatically, the cycle starts. The flashing H2O2 display confirms the process and counts down remaining H2O2vaporization time. · Positive feedback tactile input buttons · Positive feedback tactile entry and function keys 3. UV Resolution: The H2O2 atomizer automatically completes after a 7 minute cycle. The flashing UV Resolve display counts down remaining time in the UV cycle as H2O2 is reduced to water and trace oxygen. · Display contrast adjustment · Visual alarm indicator 4. Cycle Complete: When the cycle is complete the door lock releases automatically. These droplets automatically condense onto a naturally cooler section of the interior floor for easy wipe-up. UV lamp automatically ON for five minutes after door is closed decontaminates incoming room air. Useful for overnight decontamination prior to first use, clinical decontamination protocols between patients, or following total chamber wipe-out after maintenance or service. After Door Opening The SafeCellTM UV lamp cycle is factory set for normal use, and can be re-programmed as desired by entering parameters through the central microprocessor control panel. Program parameters for the H2O2 sterilization cycle are non-adjustable for operator safety. OFF 24 Hour Conventional Copper C1100 YES 7 Design & Technology Direct Heat and Air JacketTM Heating System The patented Direct Heat and Air JacketTM surrounds the inner walls with a natural convection airflow that converts to radiant wall heat through thermal conduction to achieve accurate, uniform and highly responsive temperature control within the chamber. · The microprocessor controller directs proportional distribution of power to independent heating sources surrounding the chamber. · Arranged in three zones, these sources include the side, top and rear walls, the chamber base and the outer door. · Each zone is controlled by the microprocessor which manages continuous feedback from the incubator chamber sensors. The patented Direct Heat and Air JacketTM heating system distributes proportional energy to the interior chamber through a natural convection air jacket surrounded by a high density insulation to protect against ambient temperature fluctuations Zone Main (Red) Base (Yellow) Front (Green) Air Jacket (White) Insulation (Grey) Location Side, top and rear walls Floor Outer door Function Dominant heat source Base heater elevates the humidity reservoir to achieve 95%RH at 37°C Warms the inner glass in response to ambient conditions; eliminates condensation on glass and around the opening and promotes temperature uniformity Sealed, surrounds interior chamber with natural air convection Promotes energy efficiency, mitigates effect of ambient temperature fluctuations on air jacket Energy Variable Variable Variable Microprocessor Controller Energizes any, all or a combination of heating elements as required. Side, top and rear walls Side, top and rear walls, door ­­ ­­ ­­ ­­ Shelves and Inventory Management Convenient space efficient inventory management is simplified through a system of adjustable, extendable shelves. · Inventory shelves and brackets are formed from polished stainless steel, removable without tools, and can remain inside the incubator during the H2O2 sterilization cycle or autoclaved separately if desired. · Shelves are perforated to permit natural vertical air convection through and around labware. · Shelf brackets are formed with an exaggerated angle to minimize surface contact with flat shelves*. Brackets slip easily into vertical supports that attach to interior chamber walls with clearance sufficient to permit proper air circulation. * Patent pending. 8 SterisonicTM GxP Design Elevated Humidity, Low Water Level Warning To avoid cell culture desiccation, the SANYO SterisonicTM GxP CO2 incubator maintains ~95% RH at 37°C. [. . . ] ±0. 25°C in 25°C ambient, setting 37°C, 5% CO2, no load. 0% to 20%, ±0. 15% in 25°C ambient, setting 37°C, 5% CO2, no load. Ceramic based, single beam, dual wavelength measurement of actual vs. contrast, with continuous auto-zero calibration. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SANYO MCO-5M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SANYO MCO-5M will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag