User manual SANYO PLC-WM5500L BASIC SERIAL COMMAND FUNCTIONAL SPECIFICATIONS V1.00

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SANYO PLC-WM5500L. We hope that this SANYO PLC-WM5500L user guide will be useful to you.

Lastmanuals help download the user guide SANYO PLC-WM5500L.


Mode d'emploi SANYO PLC-WM5500L
Download

You may also download the following manuals related to this product:

   SANYO PLC-WM5500L BROCHURE (2158 ko)

Manual abstract: user guide SANYO PLC-WM5500LBASIC SERIAL COMMAND FUNCTIONAL SPECIFICATIONS V1.00

Detailed instructions for use are in the User's Guide.

[. . . ] BASIC SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC-WM5500 PLC-WM5500L Ver. 1. 00 SANYO Electric Co. , Ltd DS Company Projector Division PLC-WM5500/WM5500L Basic Serial Command Functional Specifications Contents 1. Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2. Serial Interface Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2. 1. Transfer Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2. 2. [. . . ] Acceptable Unacceptable [ACK] [CR] "?" [CR] Response 15/28 PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 6. 27 INPUT 2 RGB Command Command Detail "C25" [CR] Select RGB input in Input 2. Although projector returns "OK", Input search is not executed with this command while Input button is set to Mode2 or Mode3. Acceptable Unacceptable [ACK] [CR] "?" [CR] Response 6. 28 IMAGE Command Command Detail Response "C27" [CR] Switch Image Setting status Acceptable Unacceptable [ACK] [CR] "?" [CR] 6. 29 Direct on SET Command Command Detail "C28" [CR] Enable Direct on This status is stored in EEPROM and retained regardless of Power OFF/ON operation. Acceptable Unacceptable [ACK] [CR] "?" [CR] Response 6. 30 Direct on CANCEL Command Command Detail "C29" [CR] Disable Direct on This status is stored in EEPROM and retained regardless of Power OFF/ON operation. Acceptable Unacceptable [ACK] [CR] "?" [CR] Response 6. 31 POWER MANAGEMENT READY Command Command Detail "C2A" [CR] Set Power Management function to ready status This status is stored in EEPROM and retained regardless of Power OFF/ON operation. Acceptable Unacceptable [ACK] [CR] "?" [CR] Response 6. 32 POWER MANAGEMENT CANCEL Command Command Detail "C2B" [CR] Set Power Management function to off status This status is stored in EEPROM and retained regardless of Power OFF/ON operation. Acceptable Unacceptable [ACK] [CR] "?" [CR] Response 16/28 PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 6. 33 POWER MANAGEMENT SHUTDOWN Command Command Detail "C2E" [CR] Set Power Management function to Shutdown mode. This status is stored in EEPROM and retained regardless of Power OFF/ON operation. Acceptable Unacceptable [ACK] [CR] "?" [CR] Response 6. 34 D. ZOOM + Command Command Detail Response "C30" [CR] Enter Digital Zoom mode and expand image size This command works the same way as "D. ZOOM " button of the remote control. Acceptable Unacceptable [ACK] [CR] "?" [CR] 6. 35 D. ZOOM - Command Command Detail Response "C31" [CR] Enter Digital Zoom mode and reduce image size This command works the same as "D. ZOOM " button of the remote control. Acceptable Unacceptable [ACK] [CR] "?" [CR] 6. 36 INPUT 3 VIDEO Command Command Detail "C33" [CR] Select Video input in Input 3. Although projector returns "OK", Input search is not executed with this command while Input button is set to Mode2 or Mode3. Acceptable Unacceptable [ACK] [CR] "?" [CR] Response 6. 37 INPUT 3 S-VIDEO Command Command Detail "C34" [CR] Select S-Video input in Input 3. Although projector returns "OK", Input search is not executed with this command while Input button is set to Mode2 or Mode3. Acceptable Unacceptable [ACK] [CR] "?" [CR] Response 6. 38 INPUT 3 Y, Pb/Cb, Pr/Cr Command Command Detail "C35" [CR] Select Y, Pb/Cb, Pr/Cr input in Input 3. Although projector returns "OK", Input search is not executed with this command while Input button is set to Mode2 or Mode3. Acceptable Unacceptable [ACK] [CR] "?" [CR] Response 17/28 PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 6. 39 POINTER RIGHT Command Command Detail "C3A" [CR] Move the Pointer of On-Screen Display Menu to the right. This command works differently from the command by Point button ">" of the projector or remote control and has no "Volume +" function. Acceptable Unacceptable [ACK] [CR] "?" [CR] Response 6. 40 POINTER LEFT Command Command Detail "C3B" [CR] Move the Pointer of On-Screen Display Menu to the left This command works differently from the command by Point button "<" of the projector or remote control and has no "Volume -" function. Acceptable Unacceptable [ACK] [CR] "?" [CR] Response 6. 41 POINTER UP Command Command Detail "C3C" [CR] Move up the Pointer of On-Screen Display Menu This command works the same way as "" button of the projector or remote control. Acceptable Unacceptable [ACK] [CR] "?" [CR] Response 6. 42 POINTER DOWN Command Command Detail "C3D" [CR] Move down the Pointer of On-Screen Display Menu. This command works differently from the command by "" button of the remote control and has no "Mute" Acceptable Unacceptable [ACK] [CR] "?" [CR] Response 6. 43 ENTER Command Command Detail Response "C3F" [CR] This command works the same way as "SELECT" button of the projector and remote control. [. . . ] This indicates the status turns to Standby due to lamp failure. This status continues until the next operation is started; when Power On is executed, the projector clears the information of Lamp Failure and normal operation starts. 0û "2C" [CR] Status: Cooling Down in process due to Shutter management function This indicates it has moved to Cooling down status according to the setting of Shutter Management function in setting menu. During this time, Functional Execution Commands are not accepted. 0û "8C" [CR] Status: Standby after Cooling Down due to Shutter management function. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SANYO PLC-WM5500L

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SANYO PLC-WM5500L will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag