User manual SANYO SRT-2400DC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SANYO SRT-2400DC. We hope that this SANYO SRT-2400DC user guide will be useful to you.

Lastmanuals help download the user guide SANYO SRT-2400DC.


Mode d'emploi SANYO SRT-2400DC
Download
Manual abstract: user guide SANYO SRT-2400DC

Detailed instructions for use are in the User's Guide.

[. . . ] i n d ex I INSTRUCTION MANUAL SRT-2400DC English Français Español Real Time Video Recorder Enregistreur vidéo en temps réel Videograbador en tiempo real Please read this manual carefully before connecting your VCR and operating it for the first time. Be sure to read carefully and follow all the PRECAUTIONS on page 1 and 2. Keep the manual in a safe place for future reference. PRECAUTIONS WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or other moisture. [. . . ] N 5 Press the PAUSE/SEARCH button to save the settings. NOTES: · During alarm recording all buttons are disabled. · If "OFF" is displayed on the digital display, alarm 2 Press the l (or j) button to set the desired alarm recording mode, then press the ] button. Alarm recording is done when there is an alarm trigger. Alarm recording is done only when there is an alarm trigger during programmed timer recording. Alarm recording is done only if there is an alarm trigger and the VCR is not in programmed timer recording mode. Alarm recording is done only when there is an alarm trigger during programmed timer recording duration. Alarm recording is not performed even if there is an alarm trigger. recording is not possible in order to prevent the recorded tape to be recorded over. To cancel the "OFF" display, press the STOP, EJECT, FF, REW or PLAY button. progress, recording duration for the second alarm will be calculated from that point. The alarm counter will register the alarm, but it will not be found during an alarm scan and alarm search. · If an alarm trigger is received while alarm recording is in · If there is a power failure during alarm recording, and the power is restored within the recording set duration, alarm recording will continue. not be found during an alarm scan or an alarm search. If the alarms are going to be reviewed using alarm scan or alarm search, then in 8-hour mode, 20-second or more recording duration should be used. "ALARM MODE" to "Y1" or "Y3". Alarm recording will be conducted only if the VCR is recording. · If the alarm recording duration is short, the alarms may · To do alarm recording during series recording, set 24 English ALARM RECORDING Alarm Recording Counter Display Checking the Alarm Recordings Time 1 Press the MENU button until the (ALARM TIME) menu is displayed. The number and the 8 ° recent alarm of alarm recordings, displayed. 09-25@10:52 · During alarm recording, "AL" will be flashing on the digital display. · If the ON SCREEN switch is set to the "ON" position, · The maximum display number of alarm recordings is "999", at the next alarm recording the counter will indicate "000". the number of alarms will flash on the monitor screen. · When the (ALARM TIME) menu is displayed, press the MENU RESET button to reset the alarm counter to "000" (all the data of the (ALARM TIME) menu is reset). Connections to the ALARM IN/CLOCK IN and ALARM OUT/CLOCK OUT Terminals NOTE: · The data for the previous alarm recordings is erased. · Alarm input signal 2 Press the PAUSE/SEARCH button, the normal screen is displayed. Connect a make-contact (no voltage) switch between the ALARM IN/CLOCK IN and COM terminals. Normally DC 5V are output between the ALARM OUT/CLOCK OUT and the COM terminals. When an alarm input (trigger) is received and the unit is recording, the output falls to 0V. Once the alarm recording is over, the output returns to DC 5V. · Alarm output signal NOTE: · If the MENU RESET button is pressed while the (ALARM TIME) menu is displayed, the displayed data is erased. "AL" will be erased from the digital display. English 25 ALARM RECORDING Alarm Search To go to the beginning of a desired alarm recording. Alarm Scan To look for an alarm recording by viewing the first 5 seconds of each alarm recording. 1 Press the PAUSE/SEARCH button during stop mode. 2 Press the l (or j) button to set the desired alarm ° "AL SEARCH 01" will be displayed on screen. ° The desired alarm is searched and a still image of the beginning of the alarm recording will appear on-screen. 1 Press the PAUSE/SEARCH button twice during stop mode. number (1 to 99), then press the FF (or REW) button. 2 Press the FF (or REW) button. ° "AL SCAN" will be displayed on screen. advance (or rewind) the tape ° The unit willplayback the first 5 seconds of at high speed and every alarm recording. NOTE: · The alarm number is relative to the actual tape Playback Alarm number 2 Alarm trigger input point Rewind direction 1 1 2 position. [. . . ] Refer to (USED TIME) menu for the length of time the unit has been used. As life may be shortened if foreign particles and dusts remain accumulated on the tape guides and rotating and contacting portions, clean if dirty. Dusts and other foreign particles on the tape guides may also shorten the tape life and lower picture quality, therefore clean thoroughly. English 45 TROUBLESHOOTING GUIDE If the unit does not operate normally when you follow the instructions indicated in the manual, please refer to the table below. SYMPTOM No power No image displayed on the monitor TV The buttons do not respond POSSIBLE CAUSE The power cord is not connected The connections are not correct The power to the camera and/or monitor TV is not turned on A cassette tape is not loaded All functions are suspended due to condensation Alarm recording The security lock is engaged Recording is not possible (the tape is ejected) Autorepeat recording is not possible Timer recording is not possible The loaded cassette has no erasure-prevention tab "AL" is displayed on the digital display CORRECTIVE ACTION Connect the power cord Check that all connections are correct Turn all connected devices power on Load a cassette and turn the power on Wait for the "4" indicator to go off Wait for the alarm recording to end Cancel the security lock Load a cassette tape with erasure-prevention tab or cover the tab hole with adhesive tape Display (ALARM TIME) menu, then press the MENU RESET button to turn off the "AL" indicator Set the date and time correctly Press the TIMER button to display "n" on the digital display Be sure to select "Y" for the programmed timer recordings Press the EJECT, STOP, FF, REW or PLAY button to turn the indicator off Clean the video heads Set the ON SCREEN switch to the "ON" position Unplug the power cord then plug it back in Try inserting the cassette one more time or using a new cassette. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SANYO SRT-2400DC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SANYO SRT-2400DC will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag