User manual SCHOLTES PP 93 G AT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SCHOLTES PP 93 G AT. We hope that this SCHOLTES PP 93 G AT user guide will be useful to you.

Lastmanuals help download the user guide SCHOLTES PP 93 G AT.


Mode d'emploi SCHOLTES PP 93 G AT
Download
Manual abstract: user guide SCHOLTES PP 93 G AT

Detailed instructions for use are in the User's Guide.

[. . . ] Therefore, rooms containing LPG cylinders must also be equipped with vents to allow gas to escape in the event of a leak. As a result LPG cylinders, whether partially or completely full, must not be installed or stored in rooms or storage areas that are below ground level (cellars, etc. It is advisable to keep only the cylinder being used in the room, positioned so that it is not subject to heat produced by external sources (ovens, fireplaces, stoves, etc. ) which could raise the temperature of the cylinder above 50°C. [. . . ] The yellow-green wire should be 2 or 3 cm longer than the other wires. : to make maintenance operations more efficient, the area around the hob must be easily accessible after it has been installed (i. There are no completely shutoff elements). Check that the appliance is set for the type of gas available and then connect it to the mains gas piping or the gas cylinder in compliance with current regulations and standards. This appliance is designed and set to work with the gas indicated on the label situated on the actual hob. If the gas supply is other than the type for which the appliance has been set, proceed with replacing the corresponding nozzles (provided), following instructions given in the paragraph "Adaptation to different types of gas". For trouble-free operation, suitable use of energy and longer life of the appliance, make sure that the supply pressure complies with the values indicated in the table 1 "burners and nozzles specifications, otherwise install a special pressure regulator on the supply pipe in compliance with current standards and regulations. Either a rigid metal pipe with fittings in compliance with the standards in force must be used for connecting to the nipple union (threaded ½"G male fitting) situated at the rear of the appliance to the right (Fig. 5), or flexible steel pipe in compliance with the standards in force, which must not exceed 2000 mm in length. Should it be necessary to turn the fitting, the gasket (supplied with the appliance) must be replaced. Upon completion of installation, check the gas circuit, the internal connections and the taps for leaks using a soapy solution (never a flame). Since the burner is fitted with a safety device, the knob should be pressed for approximately 2-3 seconds to allow the automatic device keeping the flame alight to heat up. When using models with an ignition button, light the desired burner pressing down the corresponding knob as far as possible and turning it anticlockwise towards the maximum setting. In this case, to activate it, simply start by turning the knob symbol, then press so that it is aligned with the it all the way in and hold it in this position for approximately 6 seconds, until the automatic device keeping the flame alight has heated up. If a flame is accidentally extinguished, turn off the control knob and wait for at least 1 minute before trying to relight it. To switch off the burner, turn the knob in a clockwise direction until it stops (when reaches the ""/"" position). The "separate double flame" burner* This burner consists of two concentric burners which can operate either together or separately. Use of the double flame on the maximum setting gives a very high power which reduces cooking times with respect to conventional burners. Moreover the double flame crown provides a more uniform distribution of heat on the bottom of the pan, when using both burners on minimum. To ensure that the double-flame burner is used to its full potential, never set the inside ring to minimum and the outside ring to maximum at the same time. pots and pans of all sizes can be used. In the case of the smaller pots and pans we recommend the use of only the internal burner. [. . . ] Disconnect your appliance from the electricity supply before carrying out any work on it. Do not use abrasive or corrosive detergents such as stain removers, anti-rust products, powder detergents or sponges with abrasive surfaces: these may scratch the surface beyond repair. Never use steam cleaners or pressure cleaners on the appliance. It is usually enough to wash the hob with a damp sponge and dry it with absorbent kitchen roll. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SCHOLTES PP 93 G AT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SCHOLTES PP 93 G AT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag