User manual SCOTSMAN FM1202RL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SCOTSMAN FM1202RL. We hope that this SCOTSMAN FM1202RL user guide will be useful to you.

Lastmanuals help download the user guide SCOTSMAN FM1202RL.


Mode d'emploi SCOTSMAN FM1202RL
Download
Manual abstract: user guide SCOTSMAN FM1202RL

Detailed instructions for use are in the User's Guide.

[. . . ] Single System RL TO THE OWNER OR USER: The service manual you are reading is intended to provide you, and the maintenance or service technician, with the information needed to install, start up, clean, maintain and service this ice system. This Remote Low side unit is the freezer portion of a commercial ice machine. It is designed to be connected to the condensing section of a refrigeration system, specifically a supermarket R-404A system. Table of Contents FOR THE INSTALLER: Specifications FOR THE INSTALLER . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FOR THE ELECTRICIAN . [. . . ] Check the bearing by: ·pushing the bail clamp back and removing the ice chute cover ·unscrewing the ice sweep ·unscrewing the breaker cover ·unscrewing the auger stud January 1997 Page 14 Single System RL CLEANING In some installations the water supply to the ice maker will be so concentrated with dissolved minerals, (such as calcium carbonate) that as ice is made, the evaporator and auger become coated with the minerals, requiring a more frequent cleaning than twice per year. If in doubt about the condition of the evaporator and auger, the auger can be removed so the parts can be inspected. Note: Water filters can filter out suspended solids, but not dissolved solids. "Soft" water may not be the complete answer. Check with a water treatment specialist regarding water treatment. Switch off electrical power, and shut off the water supply. For more information on removal of these parts, see REMOVAL AND REPLACEMENT. To remove the auger, remove front and top panel. If top panel cannot be removed, or if there is less than 6" clearance over the top of the machine, the gearmotor/evaporator may be slid out for service access. Push bail clamp back and remove ice chute cover. Loosen band clamp under ice chute, and remove ice chute from evaporator. Remove 4 allen head screws holding breaker to evaporator. Allow the auger to dry, the stainless steel of the auger and evaporator must be clean and bright. Clean the auger and evaporator as required. Reverse to reassemble. DIVIDER, AUGER AND SLOTTED COLLAR ALLEN HEAD SCREWS January 1997 Page 15 Single System RL SERVICE DIAGNOSIS: Condition - No Ice Being Produced STATUS: NOTHING OPERATES A. Check: Voltage to the unit, restore it if there is none. Check: The master switch, switch ON if off. The machine will not run if there is not enough water in the reservoir. Restore/adjust water level. STATUS: NOTHING OPERATES D. Check: The gear motor, if it will not run, the liquid line valve will not open. If no power to it: Check: The indicator lights on the circuit board, the bin empty light should be ON, the no water light should be OFF . If the bin empty and no water lights are off, check the transformer. [. . . ] The two smaller gears and the oil should be in the lower case, the output gear will be with the cover. As you lower the cover onto the lower case, cover will have to be moved closer to the second gear after the output gear has cleared the second gear top bearing. E) After the case is together, and the locating pins are secure in both ends, replace all cap screws. Bench test the gearmotor, check for oil leaks, noise, and amp draw. SEAL MOTOR BEARING GASKET January 1997 Page 23 Single System RL CIRCUIT BOARD TESTING These procedures require the machine to be connected to the power supply. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SCOTSMAN FM1202RL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SCOTSMAN FM1202RL will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag