User manual SCUBAPRO-UWATEC ALADIN AIR Z NITROX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SCUBAPRO-UWATEC ALADIN AIR Z NITROX. We hope that this SCUBAPRO-UWATEC ALADIN AIR Z NITROX user guide will be useful to you.

Lastmanuals help download the user guide SCUBAPRO-UWATEC ALADIN AIR Z NITROX.


Mode d'emploi SCUBAPRO-UWATEC ALADIN AIR Z NITROX
Download
Manual abstract: user guide SCUBAPRO-UWATEC ALADIN AIR Z NITROX

Detailed instructions for use are in the User's Guide.

[. . . ] depth Dive Planner Press 2x and 1x to activate your dive planner. The oxygen toxicity is not taken into account by calculations of the dive planner. Planning a No-Stop Dive The dive planner will only display depths which lie within the limits of the maximum allowable partial pressure of oxygen (ppO2 max). Planning a Nitrox-dive The dive planner of the Aladin® Air Z Nitrox always plans dives based on the selected oxygen percentage. [. . . ] The maximum partial pressure of oxygen can be adjusted with the DataTalk Software between 1. 20 and 1. 95 bar. A ppO2 of more than 1. 6 bar should not be set for safety reasons and is not recommended. The CNS O2%-value and -alarm is not influenced by the selected ppO2 max. Partial pressure of oxygen (ppO2) The set value and the information about the actual ppO2 are not displayed. See -> Maximum allowable partial pressure of oxygen. Surface-mode In the surface-mode the dive computer measures the build-up of micro gas bubbles and the nitrogen saturation als well as the oxygen toxicity of the tissue. The desaturation time is determined either by oxygen- or nitrogen saturation, depending on which gas takes longer. Oxygen saturation <CNS O2 %> is displayed and adjusted until the value declines to 0%. For calculations of the desaturation and No Fly Time it is assumed that the diver inhales air. Wait-mode If you need to change cylinders in this phase, make sure that the new mixture is exactly the same as the one previously used. If you want to dive with another mixture, you must have a 5-minute break at the surface to allow the Aladin® Air Z Nitrox to conclude the dive. You can then adjust the settings to the new mixture. Disregarding these rules causes the Aladin® Air Z Nitrox to calculate with wrong mixture data. Nitrox Nitrox is a gas mixture consisting of nitrogen and oxygen. The kind of air used for diving with compressed air is the same as the normal air of the earth`s atmosphere (78% nitrogen, 21% oxygen and 1% inert gases). However, Nitrox as a breathing gas for diving contains a higher percentage of oxygen than normal air. A higher percentage of oxygen (and therefore a reduced amount of nitrogen) has the advantage of lengthening the nostop phase (or reducing the decompression phase), since less nitrogen is dissolved in the diver`s body during the dive. The higher percentage of oxygen in the Nitrox-mixture can cause additional physiological problems because of the toxic effects of a hightened partial pressure of oxygen (ppO2). When breathing oxygen at a higher partial pressure, two kinds of oxygen toxicity can occur: · CNS damages: Symptoms of intoxication can occur at short notice in the central nervous system (CNS). Such symptoms are: irritation of the respiratory organs, sickness, headache, pulmonary oedema, cramps, unconsciousness. The symptoms can occur at a ppO2 of essentially more than 1 bar and they depend on the length of exposure and on the partial pressure of oxygen. · Damages of the lungs: Symptoms of pulmonary intoxication are long-term effects and may not accur immediately. [. . . ] Aladin® Air Z Nitrox must be set for a determined gas mixture. In semi-closed and closed systems the gas mixture can vary considerably. The calculations may yield results different from those necessary for the actual mixture. · Only use Aladin® Air Z Nitrox for diving with an independent breathing apparatus. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SCUBAPRO-UWATEC ALADIN AIR Z NITROX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SCUBAPRO-UWATEC ALADIN AIR Z NITROX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag