User manual SCUBAPRO-UWATEC ALADIN PRO NITROX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SCUBAPRO-UWATEC ALADIN PRO NITROX. We hope that this SCUBAPRO-UWATEC ALADIN PRO NITROX user guide will be useful to you.

Lastmanuals help download the user guide SCUBAPRO-UWATEC ALADIN PRO NITROX.


Mode d'emploi SCUBAPRO-UWATEC ALADIN PRO NITROX
Download
Manual abstract: user guide SCUBAPRO-UWATEC ALADIN PRO NITROX

Detailed instructions for use are in the User's Guide.

[. . . ] THE SYSTEM OPERATING MANUAL depth dive time Feet O2 % MIX NO STOP max. depth deco info ® American ® SWISS MADE BY UWATEC AG Safety considerations You must carefully read this entire manual before using your Aladin® Pro Nitrox. Even if you follow the instructions of this manual in a careful fashion, it is still possible that you may be seriously injured or die from decompression sickness, oxygen toxicity or some other inherent risk of scuba nitrox. Unless you are fully aware of these risks and are willing to personally accept and assume responsibility for those risks, do not use the Aladin® Pro Nitrox! WARNING The Aladin® Pro Nitrox is a decompression tool to assist a trained and certified diver in making decisions concerning dive planning and execution. [. . . ] If the ascent rate is greater than 100% of the set value, the black arrow <SLOW> appears. If the ascent rate exceeds 140%, the arrow starts flashing. The Aladin® Pro Nitrox provides an acoustic alarm if the ascent rate is 110% or greater of the set value. The intensity of the alarm increases in direct proportion to the degree the prescribed ascent rate is exceeded. max. depth deco info WARNING The prescribed ascent rate must be observed at all times!Exceeding the prescribed ascent rate can lead to microbubbles in the arterial circulation which can lead to serious injury or death due to decompression sickness. · The Aladin® Pro Nitrox may require a decompression stop even within the nostop phase because of the danger of the formation of microbubbles due to an improper ascent. · Decompression time necessary for the prevention of microbubbles can increase massively if the ascent rate is exceeded. · At great depth, too slow an ascent may cause heightened saturation of tissues and an extension of both decompression time and total ascent time. At shallow depth, a slow ascent may shorten decompression time because the tissues are desaturating during a shallow, slow ascent. · Display of the ascent rate has the priority to <CNS O2LIMIT>). 44 III Diving with Aladin® Pro Nitrox 4. Functions during the Dive Messages: WARNING Ascent rate Optical alarm S L O W Acoustic alarm III % SPEED % SPEED S L O W % SPEED S L O W % SPEED S L O W Excessive ascent rates of longer periods are entered in the logbook. Response: Reduce ascent rate III Diving with Aladin® Pro Nitrox 45 4. Functions during the Dive 4. 5 Partial pressure of oxygen The tolerable partial pressure of oxygen can be set by means of an interface cable and the DataTalk-software between 1. 2 and 1. 95 bar (see page 84). The set value or the information about the actual ppO2 are not displayed. 4 sec depth dive time Messages: O2 % MIX DECOSTOP NO STOP Depending on the mixture used and the setting of the ppO2 the limit for an attention message is reached at different depths. The Aladin® Pro Nitrox sends an acoustic attention message when the set partial pressure is reached; the indication of depth starts flashing. Go to a smaller depth in order to diminish the danger of oxygen intoxication. max. depth deco info Response: WARNING The allowed maximum depth should not be exceeded or only for a short period. Disregarding the warning can lead to oxygen intoxication. 46 III Diving with Aladin® Pro Nitrox 4. Functions during the Dive 4. 6 Oxygen toxicity depth dive time CNS O2 LIMIT O2 % MIX S L O W % Oxygen toxicity is calculated from depth values and the gas mixture by the calculation model and displayed in place of the ascent rate in percent of a maximum value tolerated (O2 clock). The toxicity is expressed in 5%-increments. [. . . ] To avoid possible problems with your Aladin® Pro Nitrox, the following recommendations will help assure that it will give you years of trouble free service: ­ Avoid dropping or jarring your Aladin® Pro Nitrox. ­ Do not allow your Aladin® Pro Nitrox to be exposed to direct, intense sunlight. ­ Rinse your Aladin® Pro Nitrox thoroughly with fresh water after each dive. ­ Do not store your Aladin® Pro Nitrox in an gas mixture-tight area; make sure there is free ventilation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SCUBAPRO-UWATEC ALADIN PRO NITROX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SCUBAPRO-UWATEC ALADIN PRO NITROX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag