User manual SEIKO 7K52 ANALOG QUARTZ

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SEIKO 7K52 ANALOG QUARTZ. We hope that this SEIKO 7K52 ANALOG QUARTZ user guide will be useful to you.

Lastmanuals help download the user guide SEIKO 7K52 ANALOG QUARTZ.


Mode d'emploi SEIKO 7K52 ANALOG QUARTZ
Download
Manual abstract: user guide SEIKO 7K52 ANALOG QUARTZ

Detailed instructions for use are in the User's Guide.

[. . . ] 7K52 INSTRUCTIONS BEDIENUNGSANLEITUNG INSTRUCTIONS ISTRUZIONI INSTRUCCIONES INSTRUÇÕES (P. 155) (185 ) English 2 You are now the proud owner of a SEIKO Analogue Quartz Watch Cal. For best results, please read the instructions in this booklet carefully before using your SEIKO Analogue Quartz Watch. Please keep this manual handy for ready reference. [. . . ] Before diving, therefore, it is recommended that you make a note of the stored data in your log book, etc. WHILE DIVING Use the watch only within the operational temperature range for depth measurement (0° C ~ 40° C or 32° F ~ 104° F). Take care not to hit the watch against hard objects such as rocks. While you are underwater, never unscrew the crown or pull it out. Check that the DEPTH hand moves properly. While you are at a depth of 1. 6 m or more underwater, the alarm will not ring so that it is not confused with the beeping sound for the rapid ascent warning. The depth measurement is made every second except while the DEPTH hand is moving. While the watch is giving the rapid ascent warning, it will not measure the depth. In some cases, however, the watch stops the warning momentarily to indicate the depth and then resumes the warning. Depending on the aquatic environment where the watch is used, the beeping sound for the 21 rapid ascent warning may or may not reach your ears. If you find the DEPTH hand indicating the 58-minute position while you are underwater, you should either ascend to the surface immediately or, if you choose to remain underwater, not depend on diving information provided by the watch. The watch measures the depth of water on the basis of seawater having a specific gravity of 1. 025. When it is used in fresh water such as lakes, therefore, the displayed depth should be corrected by multiplying it by 1. 025. Ex. Assuming that the gravity of the lake where you are diving is 1. 00 If the watch indicates 29. 2 m, the actual depth is: 29. 2 m x 1. 025/1. 00 = 30. 0 m English While you are underwater, none of the buttons will work for safety's sake. AFTER DIVING After making a dive, be sure to rinse the watch in fresh water, and wash out all seawater, soil, sand, etc. If dust forms between the case and rotating bezel, the pressure sensor will not function properly. sticking to the water contact sensor unit, as this will cause a malfunction. After cleaning the watch in fresh water, be sure to wipe it thoroughly dry to prevent possible rust on the case. stick in the sensor unit and cannot be washed out, take your watch to the retailer from whom the watch was purchased or an AUTHORIZED SEIKO DEALER or SERVICE CENTER. Be careful not to expose the watch to solvents such as alcohol and gasoline, as this may cause a malfunction of the sensors. 22 NOTES ON USING THE WATCH English TIME/CALENDAR SETTING Do not set the date between 9:00 p. m. Otherwise, the date may not change properly. Be sure to set the time hands and the small hands at the 6 o'clock position accurately to the current time as the time submerged recorded as log data is based on the time the small hands indicate. By pulling out the crown to the second click, the time hands stop moving, and the small hour and minute hands indicate the current time and stop. [. . . ] Never attempt to recharge it, as this may cause battery leakage or damage to the battery. 28 Necessary procedure after battery change English When the battery is replaced with a new one or when the watch hands move improperly, follow the procedure below. The IC is reset and then the watch operates normally. * The log data stored in memory will be erased by following the procedure below. Pull out Crown to the second click and press buttons B and C at the same time. B C Time submerged Time randomly selected Time of DATA 1 plus 6 hours Before using the watch: Set the time and date. Diving time DATA 1 DATA 2 15 minutes 30 minutes Maximum depth 20 m 40 m Average depth 10. 0 m 20. 0 m * If the above data are not properly indicated, the watch may be out of order. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SEIKO 7K52 ANALOG QUARTZ

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SEIKO 7K52 ANALOG QUARTZ will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag