User manual SEKONIC TWINMATE L-208

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SEKONIC TWINMATE L-208. We hope that this SEKONIC TWINMATE L-208 user guide will be useful to you.

Lastmanuals help download the user guide SEKONIC TWINMATE L-208.


Mode d'emploi SEKONIC TWINMATE L-208
Download
Manual abstract: user guide SEKONIC TWINMATE L-208

Detailed instructions for use are in the User's Guide.

[. . . ] In order not to crowd the controls, four functions which are less frequently used, are confined to DIP switches, located in the battery compartment. Because of its many features, the L-358 requires this rather extensive manual. But since you will never use them all at the same time, once you have learned all about it, it is simple and its use will become second nature. The Flash Master L-358 has undergone extensive quality controls at every step of manufacture. [. . . ] The measured value (f stop value) will be displayed. Set shutter speed Measured f stop value Percentage of flash in total exposure 1/10 f stop measured f stop value (total exposure) -15- ENGLISH 5. Measurement CAUTION: · There is danger of electric shock if the meter is handled with wet hands, during rain, in areas splashed by water or where there is a lot of moisture, if you use cord synchronized flash. · Under such conditions, it is recommended that you use the meter in the cordless flash mode or wireless flash radio triggering mode, and keep the Synchro terminal cap in place. NOTE: · The electronic flash unit may fire when you connect the Synchro cord or operate the POWER Switch. · For flash units with extremely low electric trigger voltage, the flash may not fire. In this case, make measurements in the cordless flash mode or wireless flash radio triggering mode. Reference: · It is possible to switch between full, 1/2 and 1/3 shutter speed stop by setting DIP switch 3 and 4. · The shutter speed can be set from 30 minutes to 1/1000 of a second. After 1/1000 sec, the meter can be set at the following intermediate speeds: 1/75, 1/80, 1/90, 1/100, 1/200, or 1/400. · If the film speed is changed after the measurement is taken, the new converted measured value (f stop value) will be displayed. · After measurement, the F stop value corresponding to the shutter speed is displayed when the shutter speed is changed. Measurement 2-3 Cord multiple flash (cumulative) mode These measurements are used when the light generated by the flash is inadequate for proper exposure. The repeated flash pops can be accumulated until the desired aperture is displayed. Only one digit is displayed if the cumulative number is ten or more. Display returns 0 (0=10, 1=11, 2=12 etc. ) 1. Slide DIP switch 2 to MULTI (see page 8) to the ON position. Hold down the Mode set button !0 and turn the Jog wheel t to select cord multiple flash (cumu. Turn the Jog wheel t to set shutter speed. When setting shutter speed, first check the settings to confirm that they correspond to the settings available on the camera. Connect the Flash synchro cord to the meter's synchro terminal i. 4. Press the Measuring button !5 to trigger a flash. The measured f stop value at that time will be displayed. Each time this is repeated, the accumulated f stop value and the number of cumulative flashes is displayed. Number of cumulative flashes Measured f stop Percentage of flash in total exposure 1/10 f stop 1st. [. . . ] F124) (with 54°lumigrid) · Repeat Accuracy · Calibration Constant Incident light metering Reflected light metering · Display Range Film speed Shutter Speeds Ambient light : +/- 0. 1 EV or less : Lumisphere C = 340 Flat diffuser C = 250 : K = 12. 5 : ISO 3 to 8000 (in 1/3 steps) : 30 minutes to 1/8000 seconds (in 1, 1/2 or 1/3 stop) also 1/200, 1/400 Cine speeds- 2, 3, 4, 6, 8, 12, 16, 18, 24, 25, 30, 32, 36, 40, 48, 50, 60, 64, 72, 96, 120, 128, 150, 200, 240, 256, 300, 360 frames per second (at a 180 degree shutter angle) : 30 minutes to 1/1000 second (in 1, 1/2 or 1/3 stop) also 1/75, 1/80, 1/90, 1/100, 1/200, 1/400 : f/1. 0 to f90. 9 (in 1/10, 1/2 or 1/3 stop) : EV -9. 9 to EV 40. 1 (in 1/10 stop) : f/1. 0 to f90 (in 1/2 stop) : 2s to 4k (1/4000) (in 1/2 stop) -33- Flash Aperture EV Analog display Aperture Shutter speed ENGLISH 8. Technical Data · Other features All-weather feature : JIS standard water resistance class 4, splash-proof type Memory function : 9 readings Memory clear · recall function Multiple Flash function : Up to flash readings (Only one digit is displayed when the cumulated number is ten or more. ) Average function : Up to 9 readings can be averaged. Brightness Difference function : +/- 9. 9 EV (in 1/10 stop) Flash analyzing function : 0 to 100% in 10% in crements Exposure Out of Range : Eu (underexposure) or Eo (overexposure) indication Exposure compensation : +/- 9. 9 EV (in 1/10 steps) Calibration compensation : +/- 1. 0 EV (in 1/10 steps) Battery Power Indicator display: with a symbol in 3 status Auto Power Off : 20 minutes after last use Auto illumination : EV 6 and under · DIP switch mode selection · Second ISO film speed setting : ISO 3 to 8000 (in 1/3 stop) · Battery used : one of CR123A battery (lithium dry cell) · Operating temperature range : -10 ~ 50°C · Storage temperature range · Dimensions · Weight : -20 ~ 60°C : 60 w × 155 h × 37 d mm : 153 g (with battery) · Standard accessories supplied : Lumigrid, Soft case, strap, synchro terminal cap, CR123A lithium battery × 1 · Radio wave frequency FCC & IC CE : CH1 ~ 16 CH17 ~ 32 : CH1 ~ 16 CH17 ~ 32 344. 0MHz 346. 5 ~ 354. 0MHz 433. 62MHz 434. 22MHz Features and specifications are subject to change without notice. -34- 9. Safety Guide ENGLISH WARNING · Please keep in a location where an infant cannot reach and accidentally get the strap wrapped around his neck. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SEKONIC TWINMATE L-208

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SEKONIC TWINMATE L-208 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag